Simultaneous analysis of citrulline and arginine in serum and tissue
被引:7
|
作者:
Mao, Hui-ming
论文数: 0引用数: 0
h-index: 0
机构:
Tongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R ChinaTongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R China
Mao, Hui-ming
[1
]
Chen, Bing-guan
论文数: 0引用数: 0
h-index: 0
机构:
Tongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R ChinaTongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R China
Chen, Bing-guan
[1
]
Wang, Wei-min
论文数: 0引用数: 0
h-index: 0
机构:
Second Mil Med Univ, Shanghai Changzheng Hosp, Dept Surg, Shanghai 200003, Peoples R ChinaTongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R China
Wang, Wei-min
[2
]
Zhuang, Ping
论文数: 0引用数: 0
h-index: 0
机构:
Shanghai Gongli Hosp, Shanghai 200135, Peoples R ChinaTongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R China
Zhuang, Ping
[3
]
Zong, Ming
论文数: 0引用数: 0
h-index: 0
机构:
Tongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R ChinaTongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R China
Zong, Ming
[1
]
Xu, Zeng-guang
论文数: 0引用数: 0
h-index: 0
机构:
Tongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R ChinaTongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R China
Xu, Zeng-guang
[1
]
机构:
[1] Tongji Univ, Sch Med, Shanghai E Hosp, Dept Cent Lab, Shanghai 200120, Peoples R China
[2] Second Mil Med Univ, Shanghai Changzheng Hosp, Dept Surg, Shanghai 200003, Peoples R China
[3] Shanghai Gongli Hosp, Shanghai 200135, Peoples R China
We developed a method for simultaneously determining L-citrulline and L-arginine levels in serum and tissue samples using RP-HPLC with ultraviolet (UV) detection. The serum was deproteinized by trichloroacetic acid and heat: the tissue was homogenized by trichloroacetic acid and deproteinized as the same as serum. Phenylisothiocyanate (PITC) solution was used as derivatization reagent and a gradient elution was carried out. The linearity for L-arginine and L-citrulline ranged from 0 to at least 1000 mu mol/L R-2 values were above 0.9999 for both. LODs for L-arginine and L-citrulline were 0.0462 mu mol/L and 0.0195 mu mol/L, respectively, while LOQs were 0.5301 mu mol/L and 0.417 mu mol/L, respectively. Intra- and inter-day CVs were less than 3.5% and 7.5% in serum, respectively. The average recovery was from 85.5% to 116.5% in serum. Intra-assay CVs were 3.8% and 10.3%, and inter-assay CVs were 13.7% and 10.7% for L-arginine and L-citrulline respectively in tissue. The average recovery was from 92.8% to 113.5% in tissue. This is a reliable and convenient analytical method which is suitable for most clinical laboratories. (C) 2010 Elsevier BM. All rights reserved.