A Comprehensive Study on Magnetoelectric Transducers for Wireless Power Transfer Using Low-Frequency Magnetic Fields

被引:14
|
作者
Hosur, Sujay [1 ]
Sriramdas, Rammohan [2 ]
Karan, Sumanta Kumar [2 ]
Liu, Na [2 ]
Priya, Shashank [2 ]
Kiani, Mehdi [1 ]
机构
[1] Penn State Univ, Sch Elect Engn & Comp Sci, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Mat Sci & Engn, University Pk, PA 16802 USA
基金
美国国家科学基金会;
关键词
Transducers; Magnetostriction; Magnetic fields; Magnetic resonance; Magnetomechanical effects; Magnetoelectric effects; Coils; Biomedical implants; efficiency; inductive coils; low-frequency operation; magnetic field; magnetoelectric transducers; wireless power transfer; TRANSMISSION; DESIGN; OPTIMIZATION; TRANSVERSE; SYSTEM; DEVICE; LINKS;
D O I
10.1109/TBCAS.2021.3118981
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetoelectric (ME) transducers, comprising of layered magnetostrictive and piezoelectric materials, are more efficient than inductive coils in converting low-frequency magnetic fields into electric fields, particularly in applications that require miniaturized devices such as biomedical implants. Therefore, ME transducers are an attractive candidate for wireless power transfer (WPT) using low-frequency magnetic fields, which are less harmful to the human body and can penetrate easily through different lossy media. The literature lacks a comprehensive study on the ME transducer as a power receiver in a WPT link. This paper studies the impact of different ME design parameters on the WPT link performance. An accurate analytical model of the ME transducer, operating in the longitudinal-transverse mode, is presented, describing both temporal and spatial deformations. Nine ME transducers with different sizes (ME volume: 5-150 mm(3)) were fabricated with Galfenol and PZT-5A as magnetostrictive and piezoelectric layers, respectively. Through the modeling and measurement of these ME transducers, the effects of the ME transducer dimension, DC bias magnetic field, loading (R-L), and operation frequency on the resonance frequency, quality factor, and received power (P-L) of the ME transducer are determined. In measurements, a 150 mm(3) ME transducer achieved > 10-fold higher P-L for a wide R-L range of 500 ohm to 1 M ohm at 95.5 kHz, compared to an optimized coil with comparable size and operation frequency.
引用
收藏
页码:1079 / 1092
页数:14
相关论文
共 50 条
  • [1] Flexible screen-printed coils for wireless power transfer using low-frequency magnetic fields
    Sondhi, K.
    Garraud, N.
    Alabi, D.
    Arnold, D. P.
    Garraud, A.
    Avuthu, S. G. R.
    Fan, Z. H.
    Nishida, T.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2019, 29 (08)
  • [2] Wireless power transmission to an electromechanical receiver using low-frequency magnetic fields
    Challa, Vinod R.
    Mur-Miranda, Jose Oscar
    Arnold, David P.
    SMART MATERIALS AND STRUCTURES, 2012, 21 (11)
  • [3] A Miniaturized, Low-Frequency Magnetoelectric Wireless Power Transfer System for Powering Biomedical Implants
    Mukherjee, Dibyajyoti
    Rainu, Simran Kaur
    Singh, Neetu
    Mallick, Dhiman
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2024, 18 (02) : 438 - 450
  • [4] Analysis of Approaches to the Efficiency Improvement of Wireless Power Transmission Systems Using Low-Frequency Magnetic Fields
    Burlaka, V. V.
    Podnebennaya, S. K.
    Gulakov, S. V.
    2018 IEEE 38TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2018, : 572 - 575
  • [5] An Electronically Reconfigurable Magnetic Metasurface for Enhanced Low-Frequency Wireless Power Transfer Applications
    Falchi, Martina
    Masi, Angelica
    Usai, Pierpaolo
    Monorchio, Agostino
    Brizi, Danilo
    IEEE JOURNAL OF MICROWAVES, 2025, 5 (02): : 312 - 321
  • [6] Fundamental Issues in Magnetoelectric Transducers: Magnetic Field Sensing Versus Wireless Power Transfer Systems
    Truong, Binh Duc
    IEEE SENSORS JOURNAL, 2020, 20 (10) : 5322 - 5328
  • [7] A System-Level Demonstration of Low-Frequency Magnetoelectric Power Transfer System
    Mukherjee, Dibyajyoti
    Mallick, Dhiman
    IEEE SENSORS LETTERS, 2025, 9 (02)
  • [8] Modelling Approach for Low-Frequency Strongly Coupled Magnetic Resonance Wireless Power Transfer System
    Rodriguez-Esteva, Agustin
    Perez Casulo, Ma Sofia
    Laborde, Bruno Serra
    Perez-Nicoli, Pablo
    Silveira, Fernando
    2016 ARGENTINE CONFERENCE OF MICRO-NANOELECTRONICS, TECHNOLOGY AND APPLICATIONS (CAMTA), 2016, : 17 - 21
  • [9] Design of a Conformal and Low-Frequency Metasurface for Magnetic Field Shielding in Wireless Power Transfer Systems
    Lazzoni, Valeria
    Dellabate, Alessandro Luigi
    Brizil, Danilo
    Monorchio, Agostino
    2024 18TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2024,
  • [10] Measurement of low-frequency magnetic fields
    Wolfmayr, Holger
    Ziemann, Peter
    Technische Sicherheit, 2017, 7 (11-12): : 54 - 58