Fully automated deep learning for knee alignment assessment in lower extremity radiographs: a cross-sectional diagnostic study

被引:48
|
作者
Simon, Sebastian [1 ,2 ]
Schwarz, Gilbert M. [1 ,3 ]
Aichmair, Alexander [1 ,2 ]
Frank, Bernhard J. H. [1 ]
Hummer, Allan [4 ]
DiFranco, Matthew D. [4 ]
Dominkus, Martin [2 ,5 ]
Hofstaetter, Jochen G. [1 ,2 ]
机构
[1] Orthopaed Hosp Vienna Speising, Michael Ogon Lab Orthopaed Res, Speisinger Str 109, A-1130 Vienna, Austria
[2] Orthopaed Hosp Vienna Speising, Dept Orthopaed Surg 2, Speisinger Str 109, A-1130 Vienna, Austria
[3] Med Univ Vienna, Dept Orthoped & Trauma Surg, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
[4] Image Biopsy Lab GmbH, Zehetnergasse 6-2-2, A-1140 Vienna, Austria
[5] Sigmund Freud Univ Vienna, Sch Med, Freudpl 1, A-1020 Vienna, Austria
关键词
Artificial intelligence; Standardization; Long-leg radiographs; Knee alignment; Big data; LOWER-LIMB; RELIABILITY;
D O I
10.1007/s00256-021-03948-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives Accurate assessment of knee alignment and leg length discrepancy is currently measured manually from standing long-leg radiographs (LLR), a process that is both time consuming and poorly reproducible. The aim was to assess the performance of a commercial available AI software by comparing its outputs with manually performed measurements. Materials and methods The AI was trained on over 15,000 radiographs to measure various clinical angles and lengths from LLRs. We performed a retrospective single-center analysis on 295 LLRs obtained between 2015 and 2020 from male and female patients over 18 years. AI and expert measurements were performed independently. Kellgren-Lawrence score and reading time were assessed. All measurements were compared and non-inferiority, mean-absolute-deviation (sMAD), and intra-class-correlation (ICC) were calculated. Results A total of 295 LLRs from 284 patients (mean age, 65 years (18; 90); 97 (34.2%) men) were analyzed. The AI model produces outputs on 98.0% of the LLRs. Manually annotations were considered as 100% accurate. For each measurement, its divergence was calculated, resulting in an overall accuracy of 89.2% when comparing the AI outputs to the manually measured. AI vs. mean observer revealed an sMAD between 0.39 and 2.19 degrees for angles and 1.45-5.00 mm for lengths. AI showed good reliability in all lengths and angles (ICC >= 0.87). Non-inferiority comparing AI to the mean observer revealed an equivalence-index (gamma) between 0.54 and 3.03 degrees for angles and - 0.70-1.95 mm for lengths. On average, AI was 130 s faster than clinicians. Conclusion Automated measurements of knee alignment and length measurements produced with an AI tool result in reproducible, accurate measures with a time savings compared to manually acquired measurements.
引用
收藏
页码:1249 / 1259
页数:11
相关论文
共 50 条
  • [1] Fully automated deep learning for knee alignment assessment in lower extremity radiographs: a cross-sectional diagnostic study
    Sebastian Simon
    Gilbert M. Schwarz
    Alexander Aichmair
    Bernhard J. H. Frank
    Allan Hummer
    Matthew D. DiFranco
    Martin Dominkus
    Jochen G. Hofstaetter
    Skeletal Radiology, 2022, 51 : 1249 - 1259
  • [2] A deep learning approach for fully automated measurements of lower extremity alignment in radiographic images
    Moon, Ki-Ryum
    Lee, Byoung-Dai
    Lee, Mu Sook
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [3] A deep learning approach for fully automated measurements of lower extremity alignment in radiographic images
    Ki-Ryum Moon
    Byoung-Dai Lee
    Mu Sook Lee
    Scientific Reports, 13
  • [4] Automated abnormality detection in lower extremity radiographs using deep learning
    Varma, Maya
    Lu, Mandy
    Gardner, Rachel
    Dunnmon, Jared
    Khandwala, Nishith
    Rajpurkar, Pranav
    Long, Jin
    Beaulieu, Christopher
    Shpanskaya, Katie
    Li Fei-Fei
    Lungren, Matthew P.
    Patel, Bhavik N.
    NATURE MACHINE INTELLIGENCE, 2019, 1 (12) : 578 - 583
  • [5] Automated abnormality detection in lower extremity radiographs using deep learning
    Maya Varma
    Mandy Lu
    Rachel Gardner
    Jared Dunnmon
    Nishith Khandwala
    Pranav Rajpurkar
    Jin Long
    Christopher Beaulieu
    Katie Shpanskaya
    Li Fei-Fei
    Matthew P. Lungren
    Bhavik N. Patel
    Nature Machine Intelligence, 2019, 1 : 578 - 583
  • [6] An AI-based system for fully automated knee alignment assessment in standard AP knee radiographs
    Cullen, Dominic
    Thompson, Peter
    Johnson, David
    Lindner, Claudia
    KNEE, 2025, 54 : 99 - 110
  • [7] Association of medial longitudinal arch height and stiffness with lower extremity alignment, pain, and disease severity in knee osteoarthritis: A cross-sectional study
    Karatas, Levent
    Karasu, Ayca Utkan
    ARCHIVES OF RHEUMATOLOGY, 2024, 39 (04) : 641 - 651
  • [8] Fully automated deep learning approach to dental development assessment in panoramic radiographs
    Ong, Seung-Hwan
    Kim, Hyuntae
    Song, Ji-Soo
    Shin, Teo Jeon
    Hyun, Hong-Keun
    Jang, Ki-Taeg
    Kim, Young-Jae
    BMC ORAL HEALTH, 2024, 24 (01):
  • [9] Assessing bone loss on radiographs of the knee in osteoarthritis -: A cross-sectional study
    Dieppe, PA
    Reichenbach, S
    Williams, S
    Gregg, P
    Watt, I
    Jüni, P
    ARTHRITIS AND RHEUMATISM, 2005, 52 (11): : 3536 - 3541
  • [10] Fully automated assessment of the knee alignment on long leg radiographs following corrective knee osteotomies in patients with valgus or varus deformities
    Mitterer, Jennyfer A.
    Huber, Stephanie
    Schwarz, Gilbert M.
    Simon, Sebastian
    Pallamar, Matthias
    Kissler, Florian
    Frank, Bernhard J. H.
    Hofstaetter, Jochen G.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (03) : 1029 - 1038