Improving mass measurement of coronary artery calcification using threshold correction and thin collimation in multi-detector row computed tomography: In vitro experiment

被引:9
|
作者
Hong, C [1 ]
Pilgram, TK [1 ]
Zhu, F [1 ]
Joe, BN [1 ]
Towler, DA [1 ]
Bae, KT [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
coronary vessels; calcification; computed tomography (CT); screening;
D O I
10.1016/S1076-6332(03)00111-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. This in vitro study was designed to improve the accuracy of coronary calcium mass measurement from computed tomography (CT) images by developing threshold-based calcium CT number correction and thin-slice spiral techniques. Materials and Methods. A cardiac CT phantom containing simulated calcified cylinders of known calcium density was scanned with sequential 4 X 2.5-, spiral 16 X 1.5-, and spiral 16 X 0.75-mm collimation on 4- and 16-detector row CT scanners. The images obtained from the spiral scans were reconstructed in various slice widths. The calcified cylinders were imaged and their mean CT number and size were measured at thresholds ranging from 50 to 390 Hounsfield unit. The calcium mass measured was compared with the actual value to determine errors, and threshold-based correction factors were derived to minimize the errors. Results. The minimum amount of measurable calcium in 1-mm cylinder was 0.3 mg at the 16 X 1.5-mm protocol and 0.2 mg at the 16 X 0.75-mm protocol. Compared with 2.5-mm sequential protocol, thin-slice spiral protocols yielded a higher radiation exposure and lower or similar image noise levels. The error in calcium mass after correction was significantly smaller than that in measured mass (P<.0001) and was consistent between the imaging protocols (P=.49). The accuracy of mass measurements was clearly improved by using thin-slice imaging protocols especially in 200-mg/cm(3) calcium density (P<.0001). Conclusion. The accuracy of calcium mass CT measurement can be improved by threshold-based calcium CT number correction and thin collimation spiral techniques.
引用
下载
收藏
页码:969 / 977
页数:9
相关论文
共 50 条
  • [1] Evaluation of coronary artery calcification by multi-detector row computed tomography for the detection of coronary artery stenosis in Japanese patients
    Kitamura, A
    Kobayashi, T
    Ueda, K
    Okada, T
    Awata, N
    Sato, S
    Shimamoto, T
    JOURNAL OF EPIDEMIOLOGY, 2005, 15 (05) : 187 - 193
  • [2] Coronary Artery Aneurysm with Thrombus Evaluated by Multi-detector Row Computed Tomography
    Mitsutake, Ryoko
    Miura, Shin-ichiro
    Tanaka, Toru
    Matsuo, Kunihiro
    Saku, Keijiro
    INTERNAL MEDICINE, 2009, 48 (05) : 339 - 341
  • [3] Is Chronic Kidney Disease Associated with Coronary Artery Stenosis or Calcification as Assessed by Multi-detector Row Computed Tomography?
    Mitsutake, Ryoko
    Miura, Shin-ichiro
    Shiga, Yuhei
    Kawamura, Akira
    Saku, Keijiro
    INTERNAL MEDICINE, 2008, 47 (21) : 1835 - 1841
  • [4] Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography
    Moselewski, F
    Ferencik, M
    Achenbach, S
    Abbara, S
    Cury, RC
    Booth, SL
    Jang, IK
    Brady, TJ
    Hoffmann, U
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) : 390 - 395
  • [5] Clinical significance of the coronary calcification score by multi-detector row computed tomography for the evaluation of coronary stenosis
    Mitsutake, R.
    Niimura, H.
    Miura, S.
    Zhang, B.
    Iwata, A.
    Nishikawa, H.
    Kumagai, K.
    Shirai, K.
    Matsunaga, A.
    Saku, K.
    ATHEROSCLEROSIS SUPPLEMENTS, 2006, 7 (03) : 268 - 268
  • [6] Multi-detector row computed tomography: imaging the coronary arteries
    Manghat, NE
    Morgan-Hughes, GJ
    Marshall, AJ
    Roobottom, CA
    CLINICAL RADIOLOGY, 2005, 60 (09) : 939 - 952
  • [7] Upstroke time of pulse wave as a predictive factor of coronary artery calcification as assessed by multi-detector row computed tomography
    Mitsutake, R.
    Miura, S. -I.
    Saku, K.
    JOURNAL OF HYPERTENSION, 2008, 26 : S313 - S313
  • [8] Confirmation of the posterior gastric artery using multi-detector row computed tomography
    Okabayashi T.
    Kobayashi M.
    Morishita S.
    Sugimoto T.
    Akimori T.
    Namikawa T.
    Okamoto K.
    Hokimoto N.
    Araki K.
    Gastric Cancer, 2005, 8 (4) : 209 - 213
  • [9] Association between coronary artery calcification score as assessed by multi-detector row computed tomography and upstroke time of pulse wave
    Mitsutake, Ryoko
    Miura, Shin-ichiro
    Saku, Keijiro
    INTERNAL MEDICINE, 2007, 46 (22) : 1833 - 1836
  • [10] Cardio-ankle vascular index as a predictive determinant for coronary artery calcification as assessed by multi-detector row computed tomography
    Mitsutake, R.
    Miura, S.
    Shiga, Y.
    Sako, H.
    Saku, K.
    EUROPEAN HEART JOURNAL, 2009, 30 : 210 - 210