Three-dimensional stabilization provided by the external spinal fixator compared to two internal fixation devices: a biomechanical in vitro flexibility study

被引:12
|
作者
Lund, T
Nydegger, T
Rathonyi, G
Nolte, LP
Schlenzka, D
Oxland, TR
机构
[1] ORTON Orthopaed Hosp, Invalid Fdn, Helsinki 00280, Finland
[2] Univ British Columbia, Dept Orthopaed, Vancouver, BC, Canada
[3] Univ British Columbia, Dept Mech Engn, Vancouver, BC, Canada
[4] Univ Bern, Maurice E Muller Inst Biomech, Bern, Switzerland
关键词
biomechanics; lumbar spine; low back pain; external spinal fixation; internal spinal fixation;
D O I
10.1007/s00586-002-0519-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We performed an in vitro study to investigate the stabilization (i.e. motion reduction) provided by the external spinal fixator (ESF), and to compare the three configurations of the ESF with two internal fixation techniques. Six human cadaveric lumbar spine specimens (L3-S1) were subjected to multidirectional flexibility testing in six configurations: (1) intact, (2) ESF in neutral, (3) ESF in distraction, (4) ESF in compression, (5) translaminar facet screw fixation, and (6) internal transpedicular fixation. Both the ESF and the internal fixation systems stabilized the specimens from L4 to S1. In each testing configuration, pure bending moments of flexion-extension, bilateral axial rotation, and bilateral lateral bending were applied to the uppermost vertebra stepwise to a maximum of 10 Nm. The rigid body motion between the vertebrae was measured using an optoelectronic camera system, and custom software was used to calculate the intervertebral rotations. For each applied motion in all testing configurations, the total range of motion (ROM) of L4-S1 is reported. All three ESF configurations stabilized the spine significantly when compared to the intact specimen. The ESF in compression provided significantly more stabilization in flexion-extension than the two other ESF configurations, but no other significant differences were found between the three ESF modes. In flexion-extension the ESF stabilized the spine significantly when compared with the two internal fixation devices. Only in bilateral lateral bending was the ESF inferior to internal transpedicular fixation in providing stabilization. The results of the present study suggest that the ESF provides a high degree of stabilization for preoperative assessment of selected low back pain patients. Whether other non-mechanical factors affect the pain relief experienced by the patients remains unknown.
引用
收藏
页码:474 / 479
页数:6
相关论文
共 50 条
  • [1] Three-dimensional stabilization provided by the external spinal fixator compared to two internal fixation devices: a biomechanical in vitro flexibility study
    Teija Lund
    Thomas Nydegger
    Gabor Rathonyi
    Lutz-Peter Nolte
    Dietrich Schlenzka
    Thomas R. Oxland
    European Spine Journal, 2003, 12 : 474 - 479
  • [2] BIOMECHANICAL EVALUATION OF SPINAL FIXATION DEVICES .2. STABILITY PROVIDED BY 8 INTERNAL-FIXATION DEVICES
    PANJABI, MM
    ABUMI, K
    DURANCEAU, J
    CRISCO, JJ
    SPINE, 1988, 13 (10) : 1135 - 1140
  • [3] A 3-DIMENSIONAL BIOMECHANICAL STUDY OF THE STABILITY PROVIDED BY VARIOUS THORACOLUMBAR FIXATION DEVICES
    PANJABI, MM
    ABUMI, K
    DURANCEAU, J
    CRISCO, JJ
    JOURNAL OF BIOMECHANICS, 1988, 21 (10) : 851 - 851
  • [4] Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study
    Niosi, Christina A.
    Zhu, Qingan A.
    Wilson, Derek C.
    Keynan, Ory
    Wilson, David R.
    Oxland, Thomas R.
    EUROPEAN SPINE JOURNAL, 2006, 15 (06) : 913 - 922
  • [5] Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study
    Christina A. Niosi
    Qingan A. Zhu
    Derek C. Wilson
    Ory Keynan
    David R. Wilson
    Thomas R. Oxland
    European Spine Journal, 2006, 15 : 913 - 922
  • [6] A THREE-DIMENSIONAL MORPOLOGICAL MEASUREMENT AND IN VITRO BIOMECHANICAL STUDY OF METATARSALS
    Niu, Wenxin
    Wang, Lejun
    Zhu, Rui
    Li, Bing
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (06)
  • [7] Biomechanical Efficacy of Three Methods for the Fixation of Posterior Malleolar Fractures: A Three-Dimensional Finite Element Study
    Giordano, Vincenzo
    Babinski, Marcio Antonio
    Freitas, Anderson
    Pires, Robinson Esteves
    de Souza, Felipe Serrao
    de Faria, Luiz Paulo Giorgetta
    Labronici, Pedro Jose
    Godoy-Santos, Alexandre
    DIAGNOSTICS, 2023, 13 (23)
  • [8] Biomechanical comparison of a circular external skeletal fixator construct to pin and tension band wire fixation for the stabilization of olecranon osteotomies in dogs: A cadaveric study
    Halling, KB
    Lewis, DD
    Cross, AR
    Sammy, RJ
    Rapoff, AJ
    VETERINARY SURGERY, 2003, 32 (04) : 324 - 335
  • [9] Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: An in vitro laboratory and three-dimensional finite element analysis
    Freitas-Junior, Amilcar C.
    Rocha, Eduardo P.
    Bonfante, Estevam A.
    Almeida, Erika O.
    Anchieta, Rodolfo B.
    Martini, Ana P.
    Assuncao, Wirley G.
    Silva, Nelson R. F. A.
    Coelho, Paulo G.
    DENTAL MATERIALS, 2012, 28 (10) : E218 - E228
  • [10] Three-dimensional dynamic external fixation of distal radial fractures. A prospective study
    Goslings, JC
    Broekhuizen, AH
    Boxma, H
    Hauet, EJ
    van Riet, YEA
    Keeman, JN
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (06): : 421 - 430