Detection of OH Radicals Generated in Wire-Plate Pulsed Corona Discharge by LIF

被引:2
|
作者
Jiang, Jian-Ping [1 ]
Luo, Zhong-Yang [1 ]
Zhao, Lei [1 ]
Xuan, Jian-Yong [1 ]
Fang, Meng-Xiang [1 ]
Gao, Xiang [1 ]
机构
[1] Zhejiang Univ, State Key Lab Energy Utilizat, Hangzhou 310027, Peoples R China
关键词
Hydroxyl (OH) radicals; input energy; laser-induced fluorescence (LIF); pulsed corona discharge (PCD); streamer; LASER-INDUCED FLUORESCENCE; ATMOSPHERIC-PRESSURE; SIMULTANEOUS REMOVAL; DYNAMICS; DENSITY; OZONE; SO2; GAS; AIR; NO;
D O I
10.1109/TPS.2015.2417972
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Hydroxyl (OH) radicals generated in wire-plate pulsed corona discharge (PCD) were detected by laser-induced fluorescence (LIF). In this paper, the 2-D distribution of OH radicals and the time-resolved development of the streamers in humidified nitrogen were recorded by an intensified charge-coupled device camera. The results indicate that the OH-LIF signals could not be detected when secondary streamer was absent in PCD with low input energy. Input energy, which varies with the configuration of wire-plate reactor and applied voltage, significantly affected the spatial distribution of OH radicals.
引用
收藏
页码:1747 / 1757
页数:11
相关论文
共 50 条
  • [1] Optical study of OH radical in a wire-plate pulsed corona discharge
    Wang, WC
    Wang, S
    Liu, F
    Zheng, W
    Wang, DZ
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2006, 63 (02) : 477 - 482
  • [2] Spectroscopic Diagnosis of Two-Dimensional Distribution of OH Radicals in Wire-Plate Pulsed Corona Discharge Reactor
    Jiang Jian-ping
    Luo Zhong-yang
    Xuan Jian-yong
    Zhao Lei
    Fang Meng-xiang
    Gao Xiang
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (10) : 2680 - 2685
  • [3] Study of Geometry Structure on a Wire-Plate Pulsed Corona Discharge Reactor
    Zhao, Lei
    Luo, Zhong-Yang
    Xuan, Jian-Yong
    Jiang, Jian-Ping
    Gao, Xiang
    Cen, Ke-Fa
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2012, 40 (03) : 802 - 810
  • [4] Diagnosis of OH radical by optical emission spectroscopy in a wire-plate bi-directional pulsed corona discharge
    Liu, Feng
    Wang, Wenchun
    Wang, Su
    Zheng, Wei
    Wang, Younian
    [J]. JOURNAL OF ELECTROSTATICS, 2007, 65 (07) : 445 - 451
  • [5] Measurement of OH spatially resolved spectrum in a wire-plate pulsed streamer discharge
    F. Liu
    W. Wang
    W. Zheng
    Y. Wang
    [J]. The European Physical Journal D, 2007, 42 : 435 - 440
  • [6] Measurement of OH spatially resolved spectrum in a wire-plate pulsed streamer discharge
    Liu, F.
    Wang, W.
    Zheng, W.
    Wang, Y.
    [J]. EUROPEAN PHYSICAL JOURNAL D, 2007, 42 (03): : 435 - 440
  • [8] OH radicals generated by DC corona discharge for improving the pulsed discharge desulfuration efficiency
    Li, J
    Li, GF
    Wu, Y
    Wang, NH
    Huang, QN
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCES, 2004, 16 (01) : 145 - 148
  • [9] Characterization of a model wire-plate pulsed corona plasma reactor
    Baldauf, M
    Hammer, T
    Hartmann, W
    Römheld, M
    [J]. PPC-2003: 14TH IEEE INTERNATIONAL PULSED POWER CONFERENCE, VOLS 1 AND 2, DIGEST OF TECHNICAL PAPERS, 2003, : 429 - 432
  • [10] Geometrical effects of the discharge system on the corona discharge and chemically active species generated in wire-cylinder and wire-plate reactors
    Kim, Y
    Park, JM
    Hong, SH
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 44 (06) : 1458 - 1467