This paper presents a new partial discharge (PD) location technique for power cables. Unlike commonly used time-domain reflectometry (TDR) methods, this technique is based on the analysis of phase difference between the direct and reflected waves of a PD pulse measured at the cable end. The phase difference at various frequencies can be obtained from the cross Fourier spectral density function. After implementing a phase unwrapping algorithm, the defect is located. This technique has been tested using the Electromagnetic Transient Program (EMTP) on the model of a 20 kV, 1-km underground cable. The simulation takes into account the frequency-dependent parameters of the cable and the measurement accuracy of the A/D converter (8-bit). The signal-to-noise ratio (SNR) varies from 10 dB to -5 dB for all computer simulations. The statistical results are given to demonstrate the performance of the proposed technique.
引用
收藏
页码:1738 / 1746
页数:9
相关论文
共 50 条
  • [1] Partial discharge location of power cables based on an improved phase difference method
    Lan, Sheng
    Hu, Yue-Qun
    Kuo, Cheng-Chien
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2019, 26 (05) : 1612 - 1619
  • [2] Single-end partial discharge location in power cables based on phase difference method
    Mardiana, Redy
    [J]. Gaodianya Jishu/High Voltage Engineering, 2011, 37 (11): : 2623 - 2628
  • [3] Partial discharge location on power cables using linear prediction
    Bidhendi, HN
    Su, Q
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 1997, : 406 - 409
  • [4] Partial discharge location on power cables using cepstrum analysis
    Bidhendi, HN
    Su, Q
    [J]. ISSPA 96 - FOURTH INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND ITS APPLICATIONS, PROCEEDINGS, VOLS 1 AND 2, 1996, : 278 - 281
  • [5] Research on Partial Discharge Source Location for Power Cables Based on Time Reversal Phase Method
    Wang, Xianjin
    Zhou, Kai
    Xie, Min
    Huang, Yonglu
    Rao, Xianjie
    Li, Rong
    [J]. Dianwang Jishu/Power System Technology, 2020, 44 (02): : 783 - 790
  • [6] Phase Difference Method for Two-end Partial Discharge Locating System of Power Cables
    Mardiana, Redy
    Su, Charles Q.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2011, 39 (09) : 863 - 878
  • [7] Partial discharge location as a diagnostic tool for power cables
    Mashikian, MS
    [J]. 2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 1604 - 1608
  • [8] Partial Discharge Location in Power Cables using a Double Ended Method Based on Time Triggering with GPS
    Mohamed, F. P.
    Siew, W. H.
    Soraghan, J. J.
    Strachan, S. M.
    McWilliam, J.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2212 - 2221
  • [9] Partial discharge location of power cables based on an improved single-terminal method
    Liang, Rui
    Zhang, Zhe
    Li, Hailong
    Chi, Peng
    Li, Guoxin
    Tao, Yunchun
    [J]. Electric Power Systems Research, 2021, 193
  • [10] Partial discharge location of power cables based on an improved single-terminal method
    Liang, Rui
    Zhang, Zhe
    Li, Hailong
    Chi, Peng
    Li, Guoxin
    Tao, Yunchun
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2021, 193