Safety and Efficacy Using the Second-Generation Cryoballoon in Patients With Atrial Fibrillation and a Common Ostium of Inferior Pulmonary Veins

被引:4
|
作者
Xie, Hai-yang [1 ]
Guo, Xiao-gang [1 ]
Yang, Jian-du [1 ]
Li, Jia-hui [1 ]
Chen, Yan-qiao [1 ]
Cao, Zhong-jing [1 ]
Sun, Qi [1 ]
Li, Xiao-yao [1 ]
Ma, Jian [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, State Key Lab Cardiovasc Dis, Arrhythmia Ctr, Fuwai Hosp,Natl Ctr Cardiovasc Dis, Beijing, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
catheter ablation; cryoballoon; atrial fibrillation; pulmonary vein; common ostium; CATHETER ABLATION; ANATOMY;
D O I
10.3389/fcvm.2021.683315
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Common ostium of inferior pulmonary veins (COIPV) is a kind of pulmonary vein variation. The safety and efficacy of COIPV isolation using the second-generation cryoballoon (CB) ablation remain unknown. Methods: A total of 10 patients with COIPV from a consecutive series of 1,751 patients with atrial fibrillation (AF) were included. Pulmonary vein isolation (PVI) was performed using the second-generation CB. Results: The prevalence of a COIPV was 0.57% in this study. PVI was achieved in all pulmonary veins (PVs) without the need for a touch-up. A segmental freeze strategy was applied for each inferior PV, respectively. The mean number of freeze cycles of inferior PVs was 1.4 +/- 0.5 for the left inferior pulmonary vein (LIPV), and 2.0 +/- 0.9 for the right inferior pulmonary vein (RIPV). Pulmonary vein potential (PVP) of RIPV could not be monitored in real-time in three cases. Eight of 10 patients (80%) were free from atrial arrhythmias without the use of antiarrhythmic drugs during a follow-up period of 23.6 +/- 12.9 months. No procedure-related complications occurred in any of the 10 patients. Conclusions: Common ostium of inferior pulmonary veins is a rare but challenging PV variant. PVI with this unusual anatomic variation using the second-generation 28-mm CB is effective and safe.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Comparison of Using Second-Generation Cryoballoon and Radiofrequency Catheter for Atrial Fibrillation Ablation in Patients With the Common Ostium of Inferior Pulmonary Veins
    Li, Jia-Hui
    Xie, Hai-Yang
    Sun, Qi
    Guo, Xiao-Gang
    Chen, Yan-Qiao
    Cao, Zhong-Jing
    Ma, Jian
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [2] Safety and efficacy of persistent atrial fibrillation ablation using the second-generation cryoballoon
    Yalin, Kivanc
    Abdin, Amr
    Lyan, Evgeny
    Sawan, Noureddin
    Liosis, Spyridon
    Elsner, Christian
    Jobs, Alexander
    Brueggemann, Ben
    Koester, Jelena
    Eitel, Ingo
    Eitel, Charlotte
    Tilz, Roland Richard
    CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (07) : 570 - 577
  • [3] Safety and efficacy of persistent atrial fibrillation ablation using the second-generation cryoballoon
    Kivanc Yalin
    Amr Abdin
    Evgeny Lyan
    Noureddin Sawan
    Spyridon Liosis
    Christian Elsner
    Alexander Jobs
    Ben Brüggemann
    Jelena Koester
    Ingo Eitel
    Charlotte Eitel
    Roland Richard Tilz
    Clinical Research in Cardiology, 2018, 107 : 570 - 577
  • [4] Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillation
    Martins, Raphael P.
    Hamon, David
    Cesari, Olivier
    Behaghel, Albin
    Behar, Nathalie
    Sellal, Jean-Marc
    Daubert, Jean-Claude
    Mabo, Philippe
    Pavin, Dominique
    HEART RHYTHM, 2014, 11 (03) : 386 - 393
  • [5] Efficacy and safety of the second-generation cryoballoon ablation for the treatment of persistent atrial fibrillation in elderly patients
    Vermeersch, Gaelle
    Abugattas, Juan-Pablo
    Varnavas, Varnavas
    De Cocker, Jeroen
    Schwagten, Bruno
    Sieira, Juan
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    De Greef, Yves
    JOURNAL OF ARRHYTHMIA, 2021, 37 (03) : 626 - 634
  • [6] Efficacy of second-generation cryoballoon ablation in paroxysmal and persistent atrial fibrillation patients
    Curnis, Antonio
    Salghetti, Francesca
    Cerini, Manuel
    Vassanelli, Francesca
    Inama, Lorenza
    Villa, Clara
    Giacopelli, Daniele
    Raweh, Abdallah
    Bontempi, Luca
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2017, 18 (09) : 655 - 662
  • [7] Optimal diameter of the pulmonary vein ostium for second-generation 28-mm cryoballoon ablation of atrial fibrillation
    Kurokawa, Sayaka
    Nagashima, Koichi
    Watanabe, Ryuta
    Arai, Masaru
    Wakamatsu, Yuji
    Otsuka, Naoto
    Yagyu, Seina
    Nakai, Toshiko
    Okumura, Yasuo
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (02): : 201 - 209
  • [8] Common ostium of the inferior pulmonary veins in a patient undergoing left atrial ablation for atrial fibrillation
    Sra, Jasbir
    Malloy, Angela
    Shah, Himal
    Krum, David
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 15 (03) : 203 - 203
  • [9] Common ostium of the inferior pulmonary veins in a patient undergoing left atrial ablation for atrial fibrillation
    Jasbir Sra
    Angela Malloy
    Himal Shah
    David Krum
    Journal of Interventional Cardiac Electrophysiology, 2006, 15 : 203 - 203
  • [10] ATRIAL FIBRILLATION ABLATION USING SECOND-GENERATION CRYOBALLOON. CRYOBALLOON ABLATION
    Baimbetov, A.
    Kuzhukeyev, M.
    Bizhanov, K.
    Ergeshov, K.
    Yakupova, I
    Bozshagulov, T.
    Ismailova, G.
    NEW ARMENIAN MEDICAL JOURNAL, 2018, 12 (01): : 64 - 71