On the brightness of diluted photon source in synchrotron light facilities

被引:5
|
作者
Ivanyan, M [1 ]
Martirosyan, Y [1 ]
Tsakanov, V [1 ]
机构
[1] Ctr Advancement Nat Discoveries Using Light Emiss, Yerevan 375040, Armenia
关键词
storage ring; emittance; undulator; brightness;
D O I
10.1016/j.nima.2004.05.080
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The undulator radiation spectral brightness in storage ring is studied taking into account the effects of the electron beam oscillating trajectory and the beam transverse size variation along the undulator. The modified optimal beta function at the source point to reach maximum brightness is obtained that is in direct relation with the emitted photons wavelength. It is shown that the maximum spectral brightness in long wavelength range is achieved with low beta lattice, while in short wavelength range With larger beta. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:651 / 656
页数:6
相关论文
共 50 条
  • [1] Facilities - Swiss approve new synchrotron light source
    Sanders, E
    PHYSICS WORLD, 1997, 10 (07) : 5 - 5
  • [2] A DECADE OF CUBAN PRESENCE IN SYNCHROTRON LIGHT SOURCE FACILITIES
    Penton-Madrigal, A.
    Estevez-Rams, E.
    Reguera, E.
    Rodriguez-Hernandez, J.
    Concepcion-Rosabal, B.
    Garcia-Basabe, Y.
    Garcia-Fernandez, R.
    Talavera, A.
    Moreno, E.
    REVISTA CUBANA DE FISICA, 2013, 30 (01): : 36 - 41
  • [3] A compact high brightness laser synchrotron light source for medical applications
    Nakajima, K
    ADVANCED ACCELERATOR CONCEPTS, EIGHTH WORKSHOP, 1999, 472 : 280 - 289
  • [4] SYNCHROTRON SOURCE - THE PHOTON BUSINESS
    不详
    NATURE, 1983, 305 (5933) : 380 - 380
  • [5] XAFS FACILITIES IN PHOTON FACTORY AND PROSPECT OF NEW SYNCHROTRON LIGHT-SOURCES IN JAPAN
    KURODA, H
    PHYSICA B, 1989, 158 (1-3): : 299 - 301
  • [6] FACILITIES AT THE NATIONAL SYNCHROTRON LIGHT-SOURCE AT BROOKHAVEN-NATIONAL-LABORATORY
    SWEET, RM
    SYNCHROTRON RADIATION IN STRUCTURAL BIOLOGY, 1989, 51 : 63 - 66
  • [7] Prospects required for future light-source facilities: a case of UVSOR synchrotron facility
    Kera, S.
    Matsui, F.
    Tanaka, K.
    Taira, Y.
    Araki, T.
    Ohigashi, T.
    Iwayama, H.
    Fujimoto, M.
    Matsuda, H.
    Salehi, E.
    Katoh, M.
    ELECTRONIC STRUCTURE, 2023, 5 (03):
  • [8] Maximum Brightness Temperature for an Incoherent Synchrotron Radio Source
    Singal, Ashok K.
    TURBULENCE, DYNAMOS, ACCRETION DISKS, PULSARS AND COLLECTIVE PLASMA PROCESSES, 2009, : 273 - 280
  • [9] STUDIES OF ION-BEAM PHOTON INTERACTIONS AT THE NATIONAL-SYNCHROTRON-LIGHT-SOURCE
    JONES, KW
    JOHNSON, BM
    HASTINGS, JB
    MERON, M
    KOSTROUN, VO
    KRUSE, TH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (02) : 1026 - 1029
  • [10] PHOTON STIMULATED DESORPTION FROM A VACUUM CHAMBER AT THE NATIONAL-SYNCHROTRON-LIGHT-SOURCE
    KOBARI, T
    HALAMA, HJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1987, 5 (04): : 2355 - 2358