Pre-applied bonded membranes - latest research and practical findings

被引:4
|
作者
Heinlein, Ulli [1 ]
Freimann, Thomas [1 ]
Bilgin, Serdar [2 ]
Filusch, Sebastian [3 ]
Meyer, Lars [2 ]
Herrmann, Knut [4 ]
机构
[1] TH Nurnberg, Kesslerpl 12, D-90489 Nurnberg, Germany
[2] Deutsch Beton & Bautech Verein EV, Kurfurstenstr 129, D-10785 Berlin, Germany
[3] Deutsch Beton & Bautech Verein EV, Bessemerstr 30, D-44793 Bochum, Germany
[4] Mat Prufanstalt Bauwesen MPA BS, Beethovenstr 52, D-38106 Braunschweig, Germany
关键词
waterproofing membranes; pre-applied bonded; attached; positive-side; blindside waterproofing; water impermeable concrete structure;
D O I
10.1002/best.202000031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Pre-applied bonded membranes have been used in Germany for several years as additional water-side sealing layers on water-impermeable concrete structures. They are intended to increase the reliability level of the waterproofing or are used as planned sealing measure for separation cracks. But planning and application are not yet subject to any regulations. Pre-applied bonded membranes are neither regarded as independent waterproofing layer nor are they regulated in combination with water impermeable concrete structures. Also, the testing of products is not yet subject to uniform principles. For this reason, fundamental properties of the pre-applied bonded membranes were determined within the project presented hereafter. Besides the determination of the hitherto existing practical experience with pre-applied membranes and the classification in the existing regulations, properties were determined and suitable test procedures were identified. These were used to determine the basic properties of ten pre-applied products, such as the protection against lateral water migration or the water impermeability of the seams. In addition, practical recommendations and quality assurance measures could be formulated.
引用
收藏
页码:671 / 683
页数:13
相关论文
共 50 条
  • [1] Nonwoven bonded pre-applied waterproofing membranes - bond development and properties
    Heinlein, Ulli
    [J]. BETON- UND STAHLBETONBAU, 2023, 118 (08) : 542 - 555
  • [2] Pre-applied mechanical bonded waterproofing membranes: Macroscopic nonwoven behavior during the concreting process
    Heinlein, Ulli
    Freimann, Thomas
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [3] Pre-applied mechanically bonded waterproofing membranes: Cement paste filtration process and influencing parameters
    Heinlein, Ulli
    Freimann, Thomas
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 62
  • [4] Pre-applied mechanically bonded waterproofing membranes: Bond strength of nonwovens to concrete and influencing parameters
    Heinlein, Ulli
    Freimann, Thomas
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 68
  • [5] Pre-applied bonded waterproofing membranes: A review of the history and state-of-the-art in Europe and North America
    Heinlen, Ulli
    Thienel, Karl-Christian
    Freimann, Thomas
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2021, 296
  • [6] Pre-applied laminating adhesive
    不详
    [J]. FOREST PRODUCTS JOURNAL, 1996, 46 (04) : 18 - 18
  • [7] Pre-applied Waterproofing Membranes Composite Mechanism and Instructions for professional Execution
    Freimann, Thomas
    Heinlein, Ulli
    [J]. BETON- UND STAHLBETONBAU, 2018, 113 (05) : 370 - 385
  • [8] PRE-APPLIED ADHESIVE SYSTEMS
    不详
    [J]. ADHESIVES AGE, 1994, 37 (12): : 41 - 41
  • [9] DBV Code of Practice Pre-applied fully bonded membrane systems as regulated construction technique
    Filusch, Sebastian
    Fingerloos, Frank
    Meyer, Lars
    Urban, Susanne
    [J]. Beton- und Stahlbetonbau, 2024, 119 (07) : 524 - 528
  • [10] AN INVESTIGATION ABOUT THE AGEING BEHAVIOUR OF PRE-APPLIED THREADLOCKERS
    De Agostinis, Massimiliano
    Croccolo, Dario
    Fini, Stefano
    Olmi, Giorgio
    Robusto, Francesco
    Scapecchi, Chiara
    [J]. PROCEEDINGS OF ASME 2022 PRESSURE VESSELS AND PIPING CONFERENCE, PVP2022, VOL 2, 2022,