Vessel structural stress mediates aortic media degeneration in bicuspid aortopathy: New insights based on patient-specific fluid-structure interaction analysis

被引:7
|
作者
Li, Fei [1 ,2 ,3 ]
Wang, Shuo [4 ]
Gao, Qi [5 ]
Chen, Xiuyu [3 ]
Yin, Gang [3 ]
Yu, Cuntao [6 ]
Wang, Yuetang [1 ,2 ]
Wang, Xu [1 ,2 ]
Qiao, En [1 ,2 ]
Meddings, Zakaria [7 ]
Wang, Wei [1 ,2 ]
Zhao, Shihua [2 ,3 ]
Teng, Zhongzhao [7 ]
机构
[1] Fuwai Hosp, Dept Struct Heart Dis, Beijing, Peoples R China
[2] Natl Ctr Cardiovasc Dis, State Key Lab Cardiovasc Dis, Natl Clin Res Ctr Cardiovasc Dis, Beijing, Peoples R China
[3] Fuwai Hosp, Dept Magnet Resonance Imaging, Beijing, Peoples R China
[4] Imperial Coll London, Data Sci Inst, London, England
[5] Zhejiang Univ, Sch Aeronaut & Astronaut, Div Fluid Engn, Hangzhou, Peoples R China
[6] Fuwai Hosp, Dept Vasc Surg, Beijing, Peoples R China
[7] Univ Cambridge, Dept Radiol, Cambridge, England
基金
中国国家自然科学基金;
关键词
Bicuspid aortic valve; Ascending aorta; Vessel structural stress; Wall shear stress; Elastin; WALL SHEAR-STRESS; NATURAL-HISTORY; VALVE; MRI; ANEURYSMS; DILATION;
D O I
10.1016/j.jbiomech.2021.110805
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study aimed to assess the relationship between local mechanical stimuli and regional aortic tissue degeneration using fluid-structure interaction (FSI) analysis in patients with bicuspid aortic valve (BAV) disease. Nine patients underwent ascending aortic replacement were recruited. Tissues were collected to evaluate the pathology features in four regions, greater curvature (GC-region), posterior (P-region), anterior (A-region), and lesser curvature (LC-region). FSI analysis was performed to quantify vessel structural stress (VSS) and flow-induced parameters, including wall shear stress (WSS), oscillatory shear index (OSI), and particle relative residence time (RRT). The correlation between these biomechanical metrics and tissue degeneration was analyzed. Elastin in the medial layer and media thickness were thinnest and the gap between fibers was biggest in the GC-region, followed by the P-region and A-region, while the elastin and media thickness were thickest and the gap smallest in the LC-region. The collagen deposition followed a pattern with the biggest in the GC-region and least in the LC-region. There is a strong negative correlation between mean or peak VSS and elastin thickness in the arterial wall in the GC-region (r = -0.917; p = 0.001 and r = -0.899; p = 0.001), A-region (r = -0.748; p = 0.020 and r = -0.700; p = 0.036) and P-region (r = -0.773; p = 0.014 and r = -0.769; p = 0.015), and between mean VSS and fiber distance in the A-region (r = -0.702, p = 0.035). Moreover, strong negative correlation between mean or peak VSS and media thickness was also observed. No correlation was found between WSS, OSI, and RRT and aortic tissue degeneration in these four regions. These findings indicate that increased VSS correlated with local elastin degradation and aortic media degeneration, implying that it could be a potential biomechanical parameter for a refined risk stratification for patients with BAV.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Patient-specific analysis of bicuspid aortic valve hemodynamics using a fully coupled fluid-structure interaction model
    Qin T.
    Mao W.
    Caballero A.
    Kamioka N.
    Lerakis S.
    Lain S.
    Elefteriades J.
    Liang L.
    Sun W.
    Computers in Biology and Medicine, 2024, 172
  • [2] Fluid-structure interaction simulations of patient-specific aortic dissection
    Baeumler, Kathrin
    Vedula, Vijay
    Sailer, Anna M.
    Seo, Jongmin
    Chiu, Peter
    Mistelbauer, Gabriel
    Chan, Frandics P.
    Fischbein, Michael P.
    Marsden, Alison L.
    Fleischmann, Dominik
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2020, 19 (05) : 1607 - 1628
  • [3] A Patient-Specific Fluid-Structure Interaction-Based Approach to Improve Surgical Predictability in Bicuspid Aortic Valve Patients
    Wanna, Charles
    Kolanjiyil, Arun
    Chandran, Krishnan B.
    Kim, Hyunggun
    Kitkungvan, Danai
    Allen, Kathryn J. Grande
    Ramzy, Danny
    McPherson, David D.
    Prakash, Siddharth K.
    Govindarajan, Vijay
    CIRCULATION, 2022, 146
  • [4] Patient-Specific Bicuspid Aortic Valve Biomechanics: A Magnetic Resonance Imaging Integrated Fluid-Structure Interaction Approach
    Emendi, Monica
    Sturla, Francesco
    Ghosh, Ram P.
    Bianchi, Matteo
    Piatti, Filippo
    Pluchinotta, Francesca R.
    Giese, Daniel
    Lombardi, Massimo
    Redaelli, Alberto
    Bluestein, Danny
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (02) : 627 - 641
  • [5] Assessment of Aortic Dissection Remodeling With Patient-Specific Fluid-Structure Interaction Models
    Baeumler, Kathrin
    Rolf-Pissarczyk, Malte
    Schussnig, Richard
    Fries, Thomas-Peter
    Mistelbauer, Gabriel
    Pfaller, Martin R.
    Marsden, Alison L.
    Fleischmann, Dominik
    Holzapfel, Gerhard A.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2025, 72 (03) : 953 - 964
  • [6] A patient-specific computational model of fluid-structure interaction in abdominal aortic aneurysms
    Wolters, BJBM
    Rutten, MCM
    Schurink, GWH
    Kose, U
    de Hart, J
    van de Vosse, FN
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (10) : 871 - 883
  • [7] On the role of tissue mechanics in fluid-structure interaction simulations of patient-specific aortic dissection
    Schussnig, Richard
    Rolf-Pissarczyk, Malte
    Baeumler, Kathrin
    Fries, Thomas-Peter
    Holzapfel, Gerhard A.
    Kronbichler, Martin
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2024, 125 (14)
  • [8] On the Modeling of Patient-Specific Transcatheter Aortic Valve Replacement: A Fluid-Structure Interaction Approach
    Luraghi, Giulia
    Migliavacca, Francesco
    Garcia-Gonzalez, Alberto
    Chiastra, Claudio
    Rossi, Alexia
    Cao, Davide
    Stefanini, Giulio
    Rodriguez Matas, Jose Felix
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2019, 10 (03) : 437 - 455
  • [9] A fluid-structure interaction analysis on hemodynamics in carotid artery based on patient-specific clinical data
    Lee, Sang Hyuk
    Kang, Seongwon
    Hur, Nahmkeon
    Jeong, Seul-Ki
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (12) : 3821 - 3831
  • [10] A fluid-structure interaction analysis on hemodynamics in carotid artery based on patient-specific clinical data
    Sang Hyuk Lee
    Seongwon Kang
    Nahmkeon Hur
    Seul-Ki Jeong
    Journal of Mechanical Science and Technology, 2012, 26 : 3821 - 3831