Device closure of residual shunt after percutaneous closure of patent foramen ovale

被引:12
|
作者
Majunke, Nicolas [1 ]
Wallenborn, Julia [1 ]
Baranowski, Andreas [1 ]
Wunderlich, Nina [1 ]
Sievert, Horst [1 ]
机构
[1] CardioVasc Ctr Frankfurt, D-60389 Frankfurt, Germany
关键词
Congenital heart disease; transcatheter closure; patent foramen ovale; residual shunt; TRANSCATHETER CLOSURE; PARADOXICAL EMBOLISM; CRYPTOGENIC STROKE; FOLLOW-UP; IMPLANTATION; OCCLUDER; EVENTS; TRIAL; RISK; SIZE;
D O I
10.4244/EIJV5I7A139
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To summarise our experiences of device closure of residual shunt after transcatheter closure of patent foramen ovale (PFO). Methods and results: Since October 1997 implantation of a second closure device was attempted in 40 patients with a moderate or large residual shunt after implantation of a PFO closure device. The mean age of the patients was 51 years. Implantation of a second closure device was technically successful in 39/40 patients (98 %). The following devices were implanted: Premere (TM) (n=20), Amplatzer (R) PFO (n=13), STARFlex (R) (n=4), Helex (TM) (n=1), Angelwings (n=1). During a mean follow-up of 36 29 months complete closure was achieved in 27 patients (69 %). The remaining shunt was small in nine patients, moderate in one and large in two. One patient with a moderate and one patient with a large residual shunt received a third device. The third patient was sent to surgery. One patient died 21 days after implantation of a third closure device due to acute pericardial tamponade. No other complications occurred. Conclusions: Transcatheter implantation of a second closure device after PFO closure is feasible. Complete closure can be achieved in the majority of patients.
引用
收藏
页码:833 / 837
页数:5
相关论文
共 50 条
  • [1] Device Closure of Residual Shunt After Percutaneous Closure of Patent Foramen Ovale
    Majunke, Nicolas
    Slaubach, Stephan
    Wunderlich, Nina
    Sievert, Horst
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 27D - 27D
  • [2] Implantation of a second closure device in patients with residual shunt after percutaneous closure of patent foramen ovale
    Schwerzmann, M
    Windecker, S
    Wahl, A
    Nedeltchev, K
    Mattle, HP
    Seiler, C
    Meier, B
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (04) : 490 - 495
  • [3] Second transcatheter closure for residual shunt following percutaneous closure of patent foramen ovale
    Susuri, Njomeza
    Obeid, Slayman
    Ulmi, Mirjam
    Siontis, George C. M.
    Wahl, Andreas
    Windecker, Stephan
    Nietlispach, Fabian
    Meier, Bernhard
    Praz, Fabien
    EUROINTERVENTION, 2017, 13 (07) : 858 - 866
  • [4] PREDICTORS OF RESIDUAL SHUNT FOLLOWING PERCUTANEOUS PATENT FORAMEN OVALE CLOSURE
    Brown, Kristen
    Haynatzki, Gleb
    Goldsweig, Andrew Michael
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 869 - 869
  • [5] Residual shunt after patent foramen ovale closure: The devil is in the details!
    Beneki, Eirini
    Dimitriadis, Kyriakos
    Kalompatsou, Argyro
    Tsioufis, Konstantinos
    Aggeli, Constantina
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 103 (05) : 751 - 751
  • [6] Reply to the letter, "Residual shunt after patent foramen ovale closure: The devil is in the details!" regarding article "Relationship between patent foramen ovale anatomical features and residual shunt after patent foramen ovale closure"
    Nakayama, Rie
    Takaya, Yoichi
    Akagi, Teiji
    Takemoto, Rika
    Haruna, Madoka
    Nakashima, Mitsutaka
    Miki, Takashi
    Nakagawa, Koji
    Toh, Norihisa
    Nakamura, Kazufumi
    Yuasa, Shinsuke
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024,
  • [7] Relationship between patent foramen ovale anatomical features and residual shunt after patent foramen ovale closure
    Rie Nakayama
    Yoichi Takaya
    Teiji Akagi
    Rika Takemoto
    Madoka Haruna
    Mitsutaka Nakashima
    Takashi Miki
    Koji Nakagawa
    Norihisa Toh
    Kazufumi Nakamura
    Cardiovascular Intervention and Therapeutics, 2024, 39 : 200 - 206
  • [8] Relationship between patent foramen ovale anatomical features and residual shunt after patent foramen ovale closure
    Nakayama, Rie
    Takaya, Yoichi
    Akagi, Teiji
    Takemoto, Rika
    Haruna, Madoka
    Nakashima, Mitsutaka
    Miki, Takashi
    Nakagawa, Koji
    Toh, Norihisa
    Nakamura, Kazufumi
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2024, 39 (02) : 200 - 206
  • [9] Percutaneous Implantation of a Second Device in Patients with Residual Right-to-Left Shunt after Patent Foramen Ovale Closure
    Rovera, Chiara
    Biasco, Luigi
    Orzan, Fulvio
    Belli, Riccardo
    Omede, Pierluigi
    Gaita, Fiorenzo
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2014, 27 (06) : 548 - 554
  • [10] Follow-up of residual shunt after patent foramen ovale closure
    Orzan, F.
    Liboni, W.
    Bonzano, A.
    Molinari, F.
    Ribezzo, M.
    Rebaudengo, N.
    Grippi, G.
    Negri, E.
    ACTA NEUROLOGICA SCANDINAVICA, 2010, 122 (04): : 257 - 261