Trans-subscapularis Portal Versus Low-Anterior Portal for Low Anchor Placement on the Inferior Glenoid Fossa: A Cadaveric Shoulder Study With Computed Tomographic Analysis

被引:10
|
作者
Dwyer, Tim [1 ,2 ]
Petrera, Massimo [1 ,2 ]
White, Lawrence M. [1 ,2 ]
Chechik, Ofir [1 ,2 ]
Wasserstein, David [1 ,2 ]
Chahal, Jaskarndip [1 ,2 ]
Veillette, Christian [1 ,2 ]
Ogilvie-Harris, Darrell J. [1 ,2 ]
Theodoropoulos, John S. [1 ,2 ]
机构
[1] Womens Coll Hosp, 76 Grenville St, Toronto, ON M5S 1B1, Canada
[2] Univ Toronto, Mt Sinai Hosp, Orthopaed Sports Med Program, Toronto, ON M5G 1X5, Canada
关键词
BANKART REPAIR; ARTHROSCOPY PORTALS; INSERTION; ANATOMY; DEFECT;
D O I
10.1016/j.arthro.2014.08.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to evaluate the accuracy of inserting a glenoid anchor at the 5:30 clockface position using a trans-subscapularis (TSS) portal versus a low anterior (LA) portal. Methods: Five surgeons (T.D., J.C., C.V., D.J.O-H., J.S.T.) placed a single anchor in 20 fresh-frozen cadaveric shoulders. In each of 2 shoulders, surgeons used an LA portal to insert the anchor, whereas in 2 shoulders a TSS portal was used. Surgeons were directed to place the anchor at the 5: 30 position at an angle 45 degrees to the glenoid surface (axial plane) and passing perpendicular to the glenoid rim in the coronal plane. Shoulders were then dissected and computed tomographic (CT) scans obtained. Anchor position relative to the clockface was documented by 2 blinded assessors, as was the angle of insertion in the axial and coronal planes. Statistical significance was calculated with a Student t test for paired samples (confidence interval [CI], 95%; significance, P < .05). Results: The average deviation from the 5: 30 position was 48 minutes (standard deviation [SD], 31 minutes) for the LA portal (average position, 4: 42 o'clock) versus 28.5 minutes (SD, 19 minutes) for the TSS group (average position, 5: 02 o'clock) (P = .15). The average angle of anchor insertion in the axial plane was 67.2 degrees (SD, 19 degrees) for the LA portal versus 62.8 degrees (SD, 14 degrees) for the TSS portal (P=.49), whereas the average angle of insertion in the coronal plane was 31.3 degrees (SD, 14 degrees) of inferior angulation in the LA group and 14.3 degrees (SD, 8 degrees) of inferior angulation in the TSS group (P=.009). Of the anchors inserted, 9 of 20 (45%) showed evidence of far-cortical perforation. No difference in cortical perforation was seen between the 2 portals, with perforation more likely with anchors inserted greater than 45 degrees in the axial plane (8 of 20) than with those inserted less than 45 degrees (1 of 20) (P=.02). Conclusions: The use of a TSS portal improves the angle of approach to the inferior glenoid rim in comparison with an LA portal, reducing the acuity of the angle of insertion in the coronal plane. Clinical Relevance: The TSS portal is an option for surgeons performing arthroscopic Bankart repair using anchors low on the glenoid rim.
引用
收藏
页码:209 / 214
页数:6
相关论文
empty
未找到相关数据