CMS pixel upgrade for the phase I: Module production and qualification

被引:0
|
作者
Moya, M. Minano [1 ]
机构
[1] Natl Taipei Univ, New Taipei 23741, Taiwan
关键词
CMS; Phase I; Pixel detector; BPIX; Module production;
D O I
10.1016/j.nima.2016.03.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The present CMS pixel detector has been designed to be fully efficient up to an LHC luminosity of 10(34) cm(-2) s(-1). However, the luminosity will increase by a factor of two in the coming years. Therefore it is planned to build and install a new detector in the extended year-end technical stop in 2016-17. Barrel pixel modules are in production since spring/summer 2015 in five different centers. Module production requires bump bonding, wire bonding and gluing processes to finally assemble a full module. To have a uniform performance of all modules standard qualification procedures have been developed. All modules will be subjected to 10 thermal cycles between +17 degrees C and -25 degrees C and then electrically tested. In addition, module performance will be verified under high rate X-rays, and internal calibrate signals used for electrical tests will be calibrated in units of electrons using well defined X-ray fluorescence lines from different target materials. The qualification criteria, based on which modules are selected to be used in the final system, will be explained in detail. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 139
页数:3
相关论文
共 50 条
  • [1] Pixel module production and qualification for the phase I upgrade of CMS
    Moya, M. Minano
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [2] Novel module production methods for the CMS pixel detector, upgrade phase I
    Blank, T.
    Caselle, M.
    Weber, M.
    Kudella, S.
    Colombo, F.
    Hansen, K.
    Arab, S.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [3] Status of the CMS Phase I pixel detector upgrade
    Spannagel, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 831 : 71 - 75
  • [4] Qualification and calibration tests of detector modules for the CMS Pixel Phase 1 upgrade
    Zhu, D.
    Backhaus, M.
    Berger, P.
    Meinhard, M.
    Starodumov, A.
    Tavolaro, V.
    [J]. JOURNAL OF INSTRUMENTATION, 2018, 13
  • [5] Performance and Phase I Upgrade Plans for the CMS Pixel Detector
    Perrey, Hanno
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1635 - 1638
  • [6] A digital readout system for the CMS Phase I Pixel Upgrade
    Stringer, R.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [7] CMS PIXEL DETECTOR FOR THE PHASE I UPGRADE AT HL-LHC
    Messineo, Alberto
    [J]. ASTROPARTICLE, PARTICLE, SPACE PHYSICS AND DETECTORS FOR PHYSICS APPLICATIONS, 2012, 7 : 623 - 629
  • [8] Phase 1 upgrade of the CMS pixel detector
    Saha, Anirban
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [9] Radiation tolerance of the readout chip for the Phase I upgrade of the CMS pixel detector
    Hoss, J.
    Kaestli, H. -C.
    Meier, B.
    Rohe, T.
    Starodumov, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2016, 11
  • [10] Test beam campaigns for the CMS Phase I Upgrade pixel readout chip