Investigation of the feasibility of non-invasive optical sensors for the quantitative assessment of dehydration

被引:0
|
作者
Visser, Cobus [1 ]
Kieser, Eduard [1 ]
Dellimore, Kiran [1 ]
van den Heever, Dawie [1 ]
Smith, Johan [2 ,3 ]
机构
[1] Stellenbosch Univ, Dept Mech & Mechatron Engn, Biomed Engn Res Grp, Stellenbosch, South Africa
[2] Tygerberg Hosp, Dept Paediat & Child Hlth, Durbanville, South Africa
[3] Stellenbosch Univ, Durbanville, South Africa
关键词
Hydration assessment; Infant dehydration; Objective measurement; Quantitative markers; CAPILLARY REFILLING TIME; DIAGNOSTIC-ACCURACY; HYDRATION; CHILDREN;
D O I
10.1016/j.medengphy.2017.06.036
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study explores the feasibility of prospectively assessing infant dehydration using four non-invasive, optical sensors based on the quantitative and objective measurement of various clinical markers of dehydration. The sensors were investigated to objectively and unobtrusively assess the hydration state of an infant based on the quantification of capillary refill time (CRT), skin recoil time (SRT), skin temperature profile (STP) and skin tissue hydration by means of infrared spectrometry (ISP). To evaluate the performance of the sensors a clinical study was conducted on a cohort of 10 infants (aged 6-36 months) with acute gastroenteritis. High sensitivity and specificity were exhibited by the sensors, in particular the STP and SRT sensors, when combined into a fusion regression model (sensitivity: 0.90, specificity: 0.78). The SRT and STP sensors and the fusion model all outperformed the commonly used "gold standard" clinical dehydration scales including the Gorelick scale (sensitivity: 0.56, specificity: 0.56), CDS scale (sensitivity: 1.0, specificity: 0.2) and WHO scale (sensitivity: 0.13, specificity: 0.79). These results suggest that objective and quantitative assessment of infant dehydration may be possible using the sensors investigated. However, further evaluation of the sensors on a larger sample population is needed before deploying them in a clinical setting. (C) 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:181 / 187
页数:7
相关论文
共 50 条
  • [1] Feasibility assessment of optical non-invasive total hemoglobin measurement
    Debreczeny, MP
    Stetson, P
    Baker, C
    OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III, 2003, 4965 : 122 - 133
  • [2] Comparison of optical sensors for non-invasive hemoglobin measurement
    Desai, Brinda
    Chaskar, Uttam
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 2211 - 2214
  • [3] Feasibility of cardiovascular risk assessment through non-invasive measurements
    Arpaia, Pasquale
    Cuocolo, Renato
    Donnarumma, Francesco
    D'Andrea, Dario
    Esposito, Antonio
    Moccaldi, Nicola
    Natalizio, Angela
    Prevete, Roberto
    2019 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR INDUSTRY 4.0 AND INTERNET OF THINGS (METROIND4.0&IOT), 2019, : 263 - 267
  • [4] Feasibility Evaluation of Metamaterial Microwave Sensors for Non-Invasive Blood Glucose Monitoring
    Malena, Lukas
    Fiser, Ondrej
    Stauffer, Paul R.
    Drizdal, Tomas
    Vrba, Jan
    Vrba, David
    SENSORS, 2021, 21 (20)
  • [5] Assessment of Liposome Biodistribution by Non-Invasive Optical Imaging: A Feasibility Study in Tumour-Bearing Mice
    Hagtvet, Eirik
    Evjen, Tove J.
    Nilssen, Esben A.
    Olsen, Dag Rune
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2012, 12 (03) : 2912 - 2918
  • [6] Non-invasive quantitative assessment of scoliosis spinal surgery outcome
    Seoud, Lama
    Cheriet, Farida
    Labelle, Hubert
    Parent, Stefan
    MEDICAL IMAGING 2013: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2013, 8672
  • [7] QUANTITATIVE NON-INVASIVE ASSESSMENT OF CAROTID-ARTERY STENOSIS
    DENDOOVEN, DJP
    CLEMENT, DL
    EUROPEAN HEART JOURNAL, 1983, 4 : 111 - 111
  • [8] QUANTITATIVE NON-INVASIVE ASSESSMENT OF PULMONARY-HYPERTENSION - IS IT ACCURATE
    MACK, R
    FISHER, J
    BORER, JS
    HOCHREITER, C
    DEVEREUX, R
    LUTAS, E
    MOSES, JW
    GOLDBERG, HL
    TAMARI, I
    CLINICAL RESEARCH, 1983, 31 (03): : A698 - A698
  • [9] Optical sensors of volatile organic compounds for non-invasive diagnosis of diseases
    Qu, Xiaoyun
    Li, Yue
    Zhang, Lin
    Moshirian-Farahi, Sareh Sadat
    Zhang, Jianmin
    Xu, Xiahong
    Liao, Ming
    Fu, Yingchun
    CHEMICAL ENGINEERING JOURNAL, 2024, 485
  • [10] Quantitative Non-invasive Assessment of Liver Disease in Preclinical Models Using Multiparametric MR Imaging: A Feasibility Study
    Hoy, Anna M.
    McDonald, Natasha
    Lennen, Ross
    Jansen, Maurits A.
    Milanesi, Matteo
    Herlihy, Amy H.
    Kendall, Timothy J.
    Mungall, William
    Gyngell, Michael L.
    Banerjee, Rajarshi
    Janiczek, Robert L.
    Murphy, Philip S.
    Fallowfield, Jonathan A.
    HEPATOLOGY, 2017, 66 : 341A - 342A