Power Generation and Oxygen Transfer Analyses for Micro Hydro-Turbine Installed in Wastewater Treatment Aeration Tank

被引:1
|
作者
Salem, Abdel Rahman [1 ]
Hasan, Alaa [1 ]
Hadi, Ahmad Abdel [1 ]
Al Hamad, Saif [1 ]
Qandil, Mohammad [1 ]
Amano, Ryoichi S. [1 ]
机构
[1] Univ Wisconsin, Dept Mech Engn, 115 E Reindl Way, Glendale, WI 53212 USA
关键词
alternative energy sources; energy conversion; systems; energy extraction of energy from its natural resource; energy systems analysis; power (co-) generation; water and wastewater treatment; SYSTEM;
D O I
10.1115/1.4052538
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study targets one of the major energy consumers in the U.S. It suggests a new mechanical system that can recover a portion of the energy in Wastewater Treatment Plants (WWTPs). The proposed system entails a hydro-turbine installed above the air diffuser in the aeration tank to extract the water-bubble current's kinetic energy and converts it to electricity. Observing the optimum location of the turbine required multiple experiments where turbine height varies between 35% and 95% (water height percentages above the diffuser), while varying the airflow between 1.42 L/s (3 CFM) and 2.12 L/s (4.5 CFM) with a 0.24 L/s (0.5 CFM) increment. Additionally, three water heights of 38.1 cm (15 ''), 53.4 cm (21 ''), and 68.6 cm (27 '') were considered to study the influence of the water height. It was noticed that the presence of the system has an adverse effect on the standard oxygen transfer efficiency (SOTE). Therefore, a small dual-blade propeller was installed right above the diffuser to directly mix the water in the bottom of the tank with the incoming air to enhance the SOTE. The results showed that the maximum reclaimed power was obtained where the hydro-turbine is installed at 65-80% above the diffuser. A reduction of up to 7.32% in SOTE was observed when the setup was placed inside the tank compared to the tank alone. The addition of the dual-blade propeller showed an increase in SOTE of 7.27% with a power loss of 6.21%, ensuring the aeration process was at its standards.
引用
收藏
页数:7
相关论文
共 28 条
  • [1] Assessment of a Francis Micro Hydro Turbine Performance Installed in a Wastewater Treatment Plant
    Tomczyk, Pawel
    Mastalerek, Krzysztof
    Wiatkowski, Miroslaw
    Kuriqi, Alban
    Jurasz, Jakub
    ENERGIES, 2023, 16 (20)
  • [2] Passivity-Based Control of Power Systems Considering Hydro-Turbine With Surge Tank
    Julian Gil-Gonzalez, Walter
    Garces, Alejandro
    Fosso, Olav Bjarte
    Escobar-Mejia, Andres
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (03) : 2002 - 2011
  • [3] The Power Reclamation of Utilizing Micro-Hydro Turbines in the Aeration Basins of Wastewater Treatment Plants
    Hasan, Alaa
    Salem, Abdel Rahman
    Hadi, Ahmad Abdel
    Qandil, Mohammad
    Amano, Ryoichi S.
    Alkhalidi, Ammar
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2021, 143 (08):
  • [4] Governors for hydro-turbine speed control in power generation: a SIMO robust design approach
    Eker, I
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (13-14) : 2207 - 2221
  • [5] Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant
    Xiaohong Zhou
    Yuanyuan Wu
    Hanchang Shi
    Yanqing Song
    Journal of Environmental Sciences, 2013, (02) : 295 - 301
  • [6] Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant
    Zhou, Xiaohong
    Wu, Yuanyuan
    Shi, Hanchang
    Song, Yanqing
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2013, 25 (02) : 295 - 301
  • [7] Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant
    Xiaohong Zhou
    Yuanyuan Wu
    Hanchang Shi
    Yanqing Song
    Journal of Environmental Sciences, 2013, 25 (02) : 295 - 301
  • [8] Time response of frequency of the hydro-turbine governing system under the coupled action of surge tank and power grid
    Peng, Z. Y.
    Yang, J. D.
    Guo, W. C.
    28TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS (IAHR2016), PTS 1-12, 2016, 49
  • [9] Wave generation in subsurface aeration system: a new approach to enhance mixing in aeration tank in wastewater treatment
    Alkhalidi, Ammar A. T.
    Al Ba'ba'a, Hasan B.
    Amano, Ryoichi S.
    DESALINATION AND WATER TREATMENT, 2016, 57 (56) : 27144 - 27151
  • [10] MICRO-HYDRO POWER GENERATION Design and Fabrication of Micro-Hydro Turbine for Water Treatement Plant
    Patrike, Nikhil P.
    Patro, Sanmaya
    MECHANICAL AND AEROSPACE ENGINEERING, PTS 1-7, 2012, 110-116 : 5265 - 5275