Significance of laminar screw fixation in the subaxial cervical spine

被引:55
|
作者
Hong, Jae Taek [1 ]
Sung, Jae Hoon [1 ]
Son, Byung Chul [1 ]
Lee, Sang Won [1 ]
Park, Chun Kun [2 ]
机构
[1] Catholic Univ, St Vincents Hosp, Dept Neurosurg, Suwon 442723, South Korea
[2] Catholic Univ, Kangnam St Marys Hosp, Dept Neurosurg, Seoul, South Korea
关键词
laminar screw; posterior instrumentation; cervical spine;
D O I
10.1097/BRS.0b013e31817d2aa2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. We retrospectively reviewed 11 patients who underwent laminar screw fixation in the subaxial cervical spine. In 4 patients, laminar screws were inserted for posterior cervical arthrodesis, and in 7 patients it was used for fixation of the open laminae during laminoplasty. Objective. In this study, the author describes the technique and surgical results of translaminar screw placement in the subaxial cervical spine. Summary of Background Data. The use of laminar screws for fixation of the second cervical vertebra and upper thoracic vertebrae has been introduced as an important technique in spinal surgery because they can avoid injury to adjacent neurovascular structures. However, there have been no reports of translaminar screw use in the subaxial spine including C7. In this study, we describe the use of translaminar screws for fixation of the subaxial cervical spine in cases of degenerative or traumatic spine disease. Methods. Between June 2006 and March 2007, 34 translaminar screws were placed in 11 patients to treat trauma or degenerative disease: 6 at C7, 6 at C6, 7 at C5, 7 at C4, 7 at C3, and 1 at T1. There were 6 women and 5 men. The ages ranged from 23 to 87 years with a mean age of 61.3 years. All patients were evaluated at 6 weeks, as well as at 3 and 6 months using flexion and extension lateral radiographs. Patients requiring fusion were also evaluated with computed tomography at 3 and 6 months to verify arthrodesis. Results. The mean follow-up period was 5.7 months, at which time there was no significant complications from laminar screw placement, except for 2 asymptomatic breaches of the dorsal lamina cortex. Sound bone fusion was identified in cases where arthrodesis was the goal. No screw pullout or avulsion was identified in the laminoplasty cases. Conclusion. The translaminar screw method avoided damaging vascular structures, especially when the vertebral artery courses in the C7 transverse foramen, and it maintains solid stabilization of the subaxial cervical spine. This technique has 2 important advantages to currently used techniques: it is simpler and is not limited by the position of vascular structures. Therefore, it may be applicable to a wider number of patients, especially as it may be used in the subaxial cervical spine.
引用
收藏
页码:1739 / 1743
页数:5
相关论文
共 50 条
  • [1] Laminar screw fixation in the subaxial cervical spine: A report on three cases
    Tanabe, Hironori
    Aota, Yoichi
    Saito, Tomoyuki
    WORLD JOURNAL OF ORTHOPEDICS, 2016, 7 (10): : 695 - 699
  • [2] Transfacetal Screw Fixation for Subaxial Cervical Spine
    Singh, Deepak K.
    Singh, Arun K.
    Nayak, Satish
    NEUROLOGY INDIA, 2022, 70 (01) : 50 - 53
  • [3] Posterior Subaxial Cervical Spine Screw Fixation: A Review of Techniques
    Joaquim, Andrei Fernandes
    Mudo, Marcelo Luis
    Tan, Lee A.
    Riew, K. Daniel
    GLOBAL SPINE JOURNAL, 2018, 8 (07) : 751 - 760
  • [4] Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine
    Kothe, R
    Rüther, W
    Schneider, E
    Linke, B
    SPINE, 2004, 29 (17) : 1869 - 1875
  • [5] Transfacet screw fixation of the subaxial cervical spine—how I do it?
    Natarajan Muthukumar
    Acta Neurochirurgica, 2013, 155 : 1235 - 1239
  • [6] Translaminar screw fixation in the subaxial pediatric cervical spine Technical note
    Jea, Andrew
    Johnson, Keyne K.
    Whitehead, William E.
    Luerssen, Thomas G.
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2008, 2 (06) : 386 - 390
  • [7] Translaminar Screw Fixation in the Subaxial Cervical Spine Quantitative Laminar Analysis and Feasibility of Unilateral and Bilateral Translaminar Virtual Screw Placement
    Alvin, Matthew D.
    Abdullah, Kalil G.
    Steinmetz, Michael P.
    Lubelski, Daniel
    Nowacki, Amy S.
    Benzel, Edward C.
    Mroz, Thomas E.
    SPINE, 2012, 37 (12) : E745 - E751
  • [8] Safety Evaluation of Freehand Lateral Mass Screw Fixation in the Subaxial Cervical Spine
    Kim, Hak-Sun
    Suk, Kyung-Soo
    Moon, Seong-Hwan
    Lee, Hwan-Mo
    Kang, Kyung Chung
    Lee, Sang-Hun
    Kim, Jin-Soo
    SPINE, 2015, 40 (01) : 2 - 5
  • [9] Anterior Transdiscal Axial Screw Fixation for Subaxial Cervical Spine: A Biomechanical Study
    Zheng, Minghui
    Ji, Wei
    Zou, Lin
    Huang, Zhiping
    Zhu, Qingan
    Qu, Dongbin
    WORLD NEUROSURGERY, 2018, 110 : E459 - E464
  • [10] Transfacet screw fixation of the subaxial cervical spine-how I do it?
    Muthukumar, Natarajan
    ACTA NEUROCHIRURGICA, 2013, 155 (07) : 1235 - 1239