Feasibility study of a personal dosemeter based upon silicon diodes used in remote controlling

被引:1
|
作者
Caresana, M [1 ]
Fazzi, A [1 ]
Varoli, V [1 ]
机构
[1] Politecn Milan, Dipartimento Ingn Nucl, I-20133 Milan, Italy
关键词
D O I
10.1093/rpd/nch490
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The availability of low cost personal dosemeters is very important for routine worker monitoring. The aim of this work is to evaluate the performance of commercial silicon diodes, commonly used for infrared communication, as a personal radiation monitor. The instrument prototype was characterised both as an area monitor and a personal monitor. Instrument response was measured in the energy range form 37 keV to Co-60 energy. The angular response was also evaluated too.
引用
收藏
页码:469 / 474
页数:6
相关论文
共 50 条
  • [1] A moderator type neutron dosemeter based on silicon diodes
    Moiseev, T
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D368 - D370
  • [2] A real-time personal neutron dosemeter based on PIPS diodes and a double layer neutron converter
    Zamani, M
    Savvidis, E
    RADIATION PROTECTION DOSIMETRY, 1996, 63 (04) : 299 - 303
  • [3] Feasibility study of extremity dosemeter based on polyallyldiglycolcarbonate (CR-39) for neutron exposure
    Chau, Q.
    Bruguier, P.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 528 - 531
  • [4] Feasibility study on an active neutron dosemeter based on carbon activation for the linear collider TESLA
    Leuschner, A
    SHIELDING ASPECTS OF ACCELERATORS, TARGETS AND IRRADIATION FACILITIES, WORKSHOP PROCEEDINGS, 2004, : 279 - 286
  • [5] Study on photon sensitivity of silicon diodes related to materials used for shielding
    Moiseev, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 432 (2-3): : 527 - 533
  • [6] A Measurement Based Feasibility Study on Remote Driving System
    Yu, Yang
    Lee, Sanghwan
    35TH INTERNATIONAL CONFERENCE ON INFORMATION NETWORKING (ICOIN 2021), 2021, : 17 - 19
  • [7] Feasibility study of using Epitaxial Silicon Diodes for clinical electron and photon beams dosimetry
    Goncalves, Josemary A. C.
    dos Santos, Thais C.
    Neves-Junior, Wellington F. P.
    Haddad, Cecilia M. K.
    Bueno, C. C.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 228 - 232
  • [8] A study of spinal analgesia based upon 357 personal cases
    Garside, E
    ANNALS OF SURGERY, 1931, 94 : 899 - 914
  • [9] Impact of a Personal Health Record Intervention Upon Surveillance Among Colorectal Cancer Survivors: Feasibility Study
    Vachon, Eric
    Robb, Bruce W.
    Haggstrom, David A.
    JMIR CANCER, 2022, 8 (03):
  • [10] Study on the web based remote monitoring and controlling system for heat exchanger
    Liu, GJ
    Tang, T
    Liu, LJ
    International Symposium on Communications and Information Technologies 2005, Vols 1 and 2, Proceedings, 2005, : 1254 - 1257