Frequency of the "push-pull effect" in US Air force fighter operations

被引:0
|
作者
Michaud, VJ [1 ]
Lyons, TJ [1 ]
Hansen, CM [1 ]
机构
[1] USAF, Sch Aerosp Med, Brooks AFB, TX 78235 USA
来源
关键词
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Recent investigation into the push-pull effect (PPE), the reduction of +Gz tolerance when preceded by less than +1 Gz, has focused on centrifuge studies to demonstrate the presence of adverse cardiovascular responses. Maneuvers found to cause the Push-Pull Effect (PPEM) have not been studied previously in U.S. Air Force (USAF) fighter aircraft. The frequency of and extent to which PPEMs are performed in fighter aircraft are unknown. Methods: Head-up display (HUD) videotapes from F-15 and F-16 air combat training missions were reviewed for the presence of PPEMs. The frequency of engagements containing PPEMs and the magnitude of the Gz profiles were noted. Results: PPEMs were found in 11 to 67% of engagements reviewed, depending on the nature of the training mission, with an overall average of 32%. The PPEMs that were observed contained segments of less than +1 Ct, ranging on average from 0.0 to 0.5 Gz for an average of 3.5 to 5 s duration. Conclusions: PPEMs are present in air combat training missions performed by today's USAF fighter aircraft and represent an operationally significant source of risk for accidents. These findings support continued research into the physiologic response to PPE and the development of countermeasures.
引用
收藏
页码:1083 / 1086
页数:4
相关论文
共 50 条
  • [1] The "push-pull effect" and G-induced loss of consciousness accidents in the US Air Force
    Michaud, VJ
    Lyons, TJ
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1998, 69 (11): : 1104 - 1106
  • [2] US push-pull on ITER
    不详
    SCIENCE, 2015, 348 (6238) : 949 - 950
  • [3] THE PUSH-PULL EFFECT
    BANKS, RD
    GRISSETT, JD
    TURNIPSEED, GT
    SAUNDERS, PL
    RUPERT, AH
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1994, 65 (08): : 699 - 704
  • [4] Performance of a push air flow in the push-pull ventilation system
    Komine, H
    Mitsuda, K
    Tsuji, K
    PROGRESS IN MODERN VENTILATION, VOL 2, PROCEEDINGS, 2000, : 28 - 32
  • [5] Push-pull frequency converter for mobile communication
    Thangavelu, AV
    Moyer, HP
    Ghanevati, M
    Daryoush, AS
    Gutierrez, R
    1997 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS I-III: HIGH FREQUENCIES IN HIGH PLACES, 1997, : 661 - 664
  • [6] On-chip push-pull effect
    Won, Rachel
    Tang, Hong
    NATURE PHOTONICS, 2009, 3 (08) : 484 - 484
  • [7] Cerebral oxygenation and push-pull effect
    Tran, Cong C.
    Etienne, Xavier
    Serra, Andre
    Berthelot, Muriel
    Ossard, Gerard
    Jouanin, Jean-C.
    Guezennec, Charles Y.
    OXYGEN TRANSPORT TO TISSUE XXVII, 2006, 578 : 331 - 336
  • [8] Push-pull deformable mirror: characterization and closed loop operations
    Chinellato, S.
    Capraro, I.
    Cardullo, A.
    Acciari, A.
    Bonora, S.
    Meneghini, G.
    Scalzotto, V.
    Trestino, C.
    Frassetto, F.
    Occhipinti, T.
    MEMS ADAPTIVE OPTICS VI, 2012, 8253
  • [9] Effect of Push-Pull HEPA Filters on Air Age in a Dental Treatment Room
    Nambu, Eriko
    Nozaki, Kazunori
    Kokomoto, Kazuma
    Hayashi, Mikako
    MEDINFO 2023 - THE FUTURE IS ACCESSIBLE, 2024, 310 : 1470 - 1471
  • [10] Quantification of the push-pull effect in substituted alkenes
    Kleinpeter, E
    Schulenburg, A
    TETRAHEDRON LETTERS, 2005, 46 (36) : 5995 - 5997