Theoretical and experimental study of combined heat and power (CHP) system integrated with ground source heat pump (GSHP)

被引:21
|
作者
Cai, Bo [1 ]
Li, Hongqiang [1 ]
Hu, Yan [2 ]
Liu, Lifang [1 ]
Huang, Jie [3 ]
Lazzaretto, Andrea [4 ]
Zhang, Guoqiang [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[2] Univ South China, Coll Civil Engn, Hengyang 421000, Hunan, Peoples R China
[3] Hunan Construct Cadre Sch, Changsha 410116, Hunan, Peoples R China
[4] Univ Padua, Dept Ind Engn, I-35131 Padua, Italy
关键词
Poly-generation; Flue gas utilization; Heat balance; Geothermal energy; Hybrid energy system; ENERGY-PERFORMANCE; CCHP SYSTEM; DESIGN; BUILDINGS; OPTIMIZATION; OPERATION; TECHNOLOGIES; COMBUSTION; GENERATION; EFFICIENCY;
D O I
10.1016/j.applthermaleng.2017.07.154
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new power and heat generation system is suggested and studied for better exploitation of the heat content of flue gases with sulfur compounds from CHP (Combined Heating and Power) systems at low temperature, and solve the heat balance problem (the heat absorbed is always unequal to that released to soil) in GSHP (Ground Source Heat Pump system). Experimental and theoretical methodologies are selected to investigate the operating performance (including heat resistance performance, heat transfer coefficient and sulfur reduction) of the key unit- a novel heat exchanger underground made of polyethylene material which can face acid environment, and a comparison is made between experimental and theoretical results. The experimental results show that the PE heat exchanger underground can support the operating temperature and bear the presence of acid. A higher amount of heat in the flue gas can be recovered because of the reduced final temperature of the exhaust gases (from 140 degrees C to 50 degrees C) and most of the emission of sulfur to the environment can be eliminated. The simulation results of the whole system indicate that the novel system makes better use of the flue gases, with total thermal (First law efficiency) and exergy (Second law efficiency) efficiencies equal to 82.7% and 28.8%, respectively, much higher than those of the reference system (73.8% and 25.8%, respectively). (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:16 / 27
页数:12
相关论文
共 50 条
  • [1] Experimental Study Of Heating-cooling Combined Ground Source Heat Pump System with Horizontal Ground Heat Exchanger
    Hu, Ying-Ning
    Peng, Ban-Jun
    Hu, Shan-Shan
    Lin, Jun
    [J]. SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 398 - 404
  • [2] An overview of the recent development of the Ground Source Heat Pump (GSHP) system in China
    Luo, Jin
    Zhang, Qi
    Liang, Changming
    Wang, Haiqi
    Ma, Xinning
    [J]. RENEWABLE ENERGY, 2023, 210 : 269 - 279
  • [3] Improvement of soybean quality by ground source heat pump (GSHP) cooling system
    Yang, Weiqiao
    Li, Xihong
    Liu, Xia
    Zhang, Yibin
    Gao, Kai
    Lv, Jianhua
    [J]. JOURNAL OF STORED PRODUCTS RESEARCH, 2015, 64 : 113 - 119
  • [4] A review of ground investigations for ground source heat pump (GSHP) systems
    Luo, Jin
    Rohn, Joachim
    Xiang, Wei
    Bertermann, David
    Blum, Philipp
    [J]. ENERGY AND BUILDINGS, 2016, 117 : 160 - 175
  • [5] Experimental study of subterranean heat exchangers in ground source heat pump system
    Wei, Jia-Xiang
    Tang, Zhi-Wei
    Ma, Chong-Fang
    Zhang, Hong-Yu
    Liu, Wen-Xue
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2007, 28 (01): : 146 - 148
  • [6] Carbon dioxide heat pipe in conjunction with a ground source heat pump (GSHP)
    Ochsner, Karl
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (16) : 2077 - 2082
  • [7] Design of a Composite Cold and Heat Source System of Air Conditioning Based on Ground Source Heat Pump (GSHP)
    Yu, Ying
    [J]. SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 649 - 654
  • [8] Theoretical study on the performance of an integrated ground-source heat pump system in a whole year
    Fan, Rui
    Jiang, Yiqiang
    Yao, Yang
    Ma, Zuiliang
    [J]. ENERGY, 2008, 33 (11) : 1671 - 1679
  • [9] Experimental heating performances of a ground source heat pump (GSHP) for heating road unit
    Zhao, Wenke
    Zhang, Yaning
    Chen, Xin
    Su, Wentao
    Li, Bingxi
    Fu, Zhongbin
    [J]. ENERGY CONVERSION AND MANAGEMENT-X, 2020, 7 (07)
  • [10] Adjustable performance analysis of combined cooling heating and power system integrated with ground source heat pump
    Wang, Jiangjiang
    Chen, Yuzhu
    Dou, Chao
    Gao, Yuefen
    Zhao, Zheng
    [J]. ENERGY, 2018, 163 : 475 - 489