Comparison of the tube test and column agglutination techniques for anti-A/-B antibody titration in healthy individuals

被引:10
|
作者
Matsuura, Hideaki [1 ,2 ]
Akatsuka, Yoshiki [1 ,3 ]
Matsuno, Takahiro [1 ,2 ]
Sugiura, Yukari [1 ,2 ]
Arakawa, Shoko [1 ,2 ]
Oikawa, Shota [1 ,2 ]
Yoshida, Jumpei [4 ]
Kosugi, Mitsuaki [4 ]
Emi, Nobuhiko [3 ]
机构
[1] Fujita Hlth Univ Hosp, Dept Blood Transfus, Toyoake, Aichi, Japan
[2] Fujita Hlth Univ Hosp, Dept Clin Lab, Toyoake, Aichi, Japan
[3] Fujita Hlth Univ, Dept Hematol, Toyoake, Aichi, Japan
[4] Ortho Clin Diagnost, Immunohematol Business Unit, Tokyo, Japan
关键词
antibody titration; column agglutination technique; pretransplantation; tube test technique; ABO; TITER; GEL; TRANSPLANTATION; SPLENECTOMY; PERFORMANCE; ASSAY;
D O I
10.1111/vox.12713
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives Materials and Methods Determination of the anti-A/-B titre pre- and post-transplantation is beneficial for treatment selection. Currently, the recommended method for antibody titration is the tube test (TT) assay. Dithiothreitol (DTT) is used for IgM antibody inactivation. Recently, a fully automated antibody titration assay using the column agglutination technique (CAT) was developed (auto-CAT). Our aim was to compare the auto-CAT and TT techniques for ABO antibody titration, to evaluate the effectiveness of DTT-treated plasma for use with auto-CAT and to define the cut-off value for antibody titration by auto-CAT. We enrolled 30 healthy individuals, including 10 each for blood types A, B and O. We performed antibody titre measurement using the TT technique and auto-CAT simultaneously. Auto-CAT uses the bead column agglutination technology. Results Conclusion With the auto-CAT cut-off value set to weak (w)+ with DTT treatment plasma, the concordance rate was 45%, and the weighted kappa value between TT and auto-CAT results was 0 center dot 994 in all subjects. Furthermore, there was a significant positive correlation between the anti-A/-B titre results obtained using the TT technique and auto-CAT in all blood types. Moreover, a positive bias (falsely elevated end-points due to agglomeration of A/B cells) was not observed in auto-CAT testing using DTT-treated plasma. Our results show that 1+ agglutination using the TT technique is equivalent to w+ agglutination obtained using auto-CAT. We recommend that DTT may be used with auto-CAT to measure antibody titres. Thus, we suggest that auto-CAT is useful for antibody titration in routine examination.
引用
收藏
页码:787 / 794
页数:8
相关论文
共 24 条
  • [1] Comparison of Total and IgG ABO Antibody Titers in Healthy Individuals by Using Tube and Column Agglutination Techniques
    Park, Eun Su
    Jo, Kyung Il
    Shin, Jeong Won
    Park, Rojin
    Choi, Tae Yoon
    Bang, Hae In
    Chai, Gum Ran
    Yun, Soon Gyu
    [J]. ANNALS OF LABORATORY MEDICINE, 2014, 34 (03) : 223 - 229
  • [2] Comparison between tube test and automated column agglutination technology on VISION Max for anti-A/B isoagglutinin titres: A multidimensional analysis
    Nam, Minjeong
    Hur, Mina
    Lee, Hyunkyung
    Kim, Hanah
    Park, Mikyoung
    Moon, Hee-Won
    Yun, Yeo-Min
    [J]. VOX SANGUINIS, 2022, 117 (03) : 399 - 407
  • [3] COMPARATION OF CONVENTIONAL TUBE METHOD WITH GEL COLUMN METHOD FOR ANTI-A/B TITRATION
    Hecimovic, A.
    Haspl, Hundric Z.
    Loncar, Jurakovic N.
    Galic, Kruhonja Z.
    Jagnjic, S.
    Balija, M.
    Jukie, I
    [J]. VOX SANGUINIS, 2013, 105 : 203 - 203
  • [4] Feasibility of the automated column agglutination technique for titration of anti-A/B antibodies in ABO-incompatible living kidney transplantation
    Matsuura, Hideaki
    Sugiura, Yukari
    Matsuno, Takahiro
    Tomiya, Yume
    Shiraki, Mari
    Kato, Chiaki
    Ishihara, Keiko
    Fukami, Harue
    Niwa, Reiko
    Hayashi, Megumi
    Matsushita, Tadashi
    Kato, Hidefumi
    Watarai, Yoshihiko
    Ito, Taihei
    Kenmochi, Takashi
    Fujii, Sumie
    Miura, Yasuo
    [J]. THERAPEUTIC APHERESIS AND DIALYSIS, 2022, 26 (04) : 827 - 835
  • [5] PARALLEL COMPARISON OF GEL, COLUMN AND TUBE AGGLUTINATION FOR ANTIBODY DETECTION
    PODLOSKY, L
    TSANG, O
    BOSHKOV, L
    [J]. TRANSFUSION, 1993, 33 (09) : S19 - S19
  • [6] Antibody titers in donor units: Comparison of anti-A and anti-B to other blood groups antibodies
    Lee, Grace C. B.
    Prihoda, LeeA
    [J]. TRANSFUSION, 2008, 48 (02) : 182A - 182A
  • [7] COMPARISON OF GEL TEST AND CONVENTIONAL TUBE TEST FOR ANTIBODY DETECTION AND TITRATION IN D-NEGATIVE PREGNANT WOMEN
    Marwaha, N.
    Thakur, M. K.
    Thakral, B.
    Saluja, K.
    Saha, S. C.
    [J]. VOX SANGUINIS, 2012, 103 : 232 - 233
  • [8] Reduction of Anti-A and Anti-B Isoagglutinin Titers of Group O Platelet Units with an ABO Antibody Immune Adsorption Column
    Robbins, M.
    Proffitt, S.
    Eastwood, G.
    Huish, S.
    Nilsson, K.
    Cardigan, R.
    [J]. TRANSFUSION, 2023, 63 : 160A - 161A
  • [9] Comparison of conventional tube test with diamed gel microcolumn assay for anti-D titration
    Novaretti, MCZ
    Jens, E
    Pagliarini, T
    Bonifácio, SL
    Dorlhiac-Llacer, PE
    Chamone, DAF
    [J]. CLINICAL AND LABORATORY HAEMATOLOGY, 2003, 25 (05): : 311 - 315
  • [10] Comparison of the indirect fluorescent antibody test and modified agglutination test for detection of anti-Toxoplasma gondii antibodies in rats
    Cola, Gustavo Antonio
    Garcia, Joao Luis
    da Costa, Leticia
    Ruffolo, Bruno
    Navarro, Italmar Teodorico
    Freire, Roberta Lemos
    [J]. SEMINA-CIENCIAS AGRARIAS, 2010, 31 (03): : 717 - 722