Revitalization of abandoned oil and gas wells for a geothermal heat exploitation by means of closed circulation: Case study of the deep dry well Pcelic-1

被引:19
|
作者
Macenic, Marija [1 ]
Kurevija, Tomislav [2 ]
机构
[1] Univ Zagreb, Fac Min Geol & Petr Engn, Dept Petr Engn, Zagreb, Croatia
[2] Univ Zagreb, Fac Min Geol & Petr Engn, Zagreb, Croatia
关键词
POWER-GENERATION; ENERGY; SYSTEM; PART;
D O I
10.1190/INT-2017-0079.1
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The aim of our research is to use abandoned deep-hydrocarbon reservoirs and dry wells in the Croatian part of the Pannonian Basin as a geothermal energy source. Croatia has been exploring and exploiting hydrocarbon reserves in the Pannonian Basin from the mid-20th century. Therefore, many oil and gas wells are reaching the end of their production phase and many are already abandoned. These wells could be considered for geothermal energy production through the coaxial heat exchanger principle, which is usually used in shallow geothermal energy extraction. Using the abandoned deep well Pcelic located in the Drava subbasin as a case study, we have derived the available energy and fluid temperature changes during 20 years of operation for two cases: one with a constant base heat load throughout the year and the second as a variable heat load depending on outside air temperatures. We determined that the maximum potential heat extraction in a variable system is 1750 MWh per year, with 1.5 MW of peak heating power in winter, depending on the sink temperature, climate, and consumer input data. The maximum theoretical constant heat extraction for possible industrial direct heating could be 400 kW during the entire period of 20 years, with fluid temperature reaching steady state at a favorable 50 degrees C. To define steady-state ratio between extracted heat and consumed energy at the circulating pump, we evaluated seasonal performance factor (SPF) analysis similar to heat pump systems. Lower values of SPF linked to a higher flow rate implies higher energy extraction. Our results show that when using a lower flow, steady-state SPF ratio is as high as 280, and for a higher flow, steady-state SPF ratio drops to only 25.
引用
收藏
页码:SB1 / SB9
页数:9
相关论文
共 3 条
  • [1] Abandoned oil and gas wells exploitation by means of closed-loop geothermal systems: a review
    Lo Russo, Stefano
    Gizzi, Martina
    Taddia, Glenda
    [J]. GEAM-GEOINGEGNERIA AMBIENTALE E MINERARIA-GEAM-GEOENGINEERING ENVIRONMENT AND MINING, 2020, (160): : 3 - 11
  • [2] Study of Heat Transfer Characteristics and Economic Analysis of a Closed Deep Coaxial Geothermal Heat Exchanger Retrofitted from an Abandoned Oil Well
    Liu, Rui-Jia
    Jia, Lin-Rui
    Zhang, Wen-Shuo
    Yu, Ming-Zhi
    Zhao, Xu-Dong
    Cui, Ping
    [J]. SUSTAINABILITY, 2024, 16 (04)
  • [3] Utilization of abandoned oil well logs and seismic data for modeling and assessing deep geothermal energy resources: A case study
    Shawky, Ahmed
    El-Anbaawy, Mohamed Ibrahim
    Soliman, Reham
    Shaheen, Eslam Nasr
    Osman, Osama Abdelaziz
    Hafiez, Hesham Eid Abdel
    Shallaly, Nahla Ahmed
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 946