Gamma Ray Induced Modifications in Cellulose Triacetate Polymer used as a Solid-State Nuclear Track Detector

被引:6
|
作者
Prasher, Sangeeta [1 ]
Kumar, Mukesh [2 ]
Singh, Surinder [3 ]
机构
[1] Kanya Maha Vidhayalya, Dept Phys, Jalandhar 144004, India
[2] Lovely Profss Univ, Dept Phys, Chaheru 144411, Phagwara, India
[3] Guru Nanak Dev Univ, Dept Phys, Amritsar 143005, Punjab, India
关键词
CR-39; IONS; CO2;
D O I
10.1063/1.4990308
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The effects of gamma radiations from a Co-60 source on the easily available overhead projector transparency have been analyzed. FTIR and UV-VIS spectra of the polymer before and after irradiation have been recorded and from the spectral data some modifications in the properties have been investigated.. The band gap energy has been calculated from the UV-VIS spectral data and it was found to remain constant up to a gamma dose of 10(3)krad and decreases thereafter. FTIR studies reveal the fact that there is a generation of CO2 and -OH groups at higher doses, which is further confirmed from the decarboxylation mechanism in esters. Aliphatic C-H stretching intensity has also been found to increase with gamma dose. The changes in track registration properties of the polymer alongwith the activation energies for bulk and track etch rates have been observed. The etch rates have been observed to increase, which can accounts for the presence of oxygen. It is found that overhead projector transparency is a highly radiation resistant polymer as it is influenced to a very little extent up to the dose of 10(3)krad. The changes are pronounced at higher gamma doses of the order of 5x10(4) and 10(5)krad.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] SENSITIVITY OF A CELLULOSE TRIACETATE SOLID-STATE TRACK DETECTOR
    PRETZSCH, G
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1981, 48 (01): : 51 - 60
  • [2] Modifications induced by gamma irradiation to Makrofol polymer nuclear track detector
    Tayel, A.
    Zaki, M. F.
    El Basaty, A. B.
    Hegazy, Tarek M.
    JOURNAL OF ADVANCED RESEARCH, 2015, 6 (02) : 219 - 224
  • [3] MEASUREMENT OF GAMMA-DOSE BY MEANS OF A CELLULOSE NITRATE SOLID-STATE NUCLEAR TRACK DETECTOR
    VARNAGY, M
    NUCLEAR INSTRUMENTS & METHODS, 1978, 152 (2-3): : 591 - 593
  • [4] Gamma-ray-induced modifications in microscopic glass slide used as a track detector
    Singh, Surinder
    Sandhu, Amanpreet Kaur
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2006, 161 (04): : 235 - 239
  • [5] ANOMALOUS NUCLEAR PHENOMENA AND SOLID-STATE NUCLEAR TRACK DETECTOR
    LI, XZ
    MO, DW
    ZHANG, L
    WANG, SC
    KANG, TS
    LIU, SJ
    WANG, J
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 599 - 604
  • [6] CONDUCTIMETRIC STUDY OF CELLULOSE NITRATE AS A SOLID-STATE TRACK DETECTOR
    ROUX, F
    BOURDEAU.M
    BISSET, JP
    BRIAND, C
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1973, 24 (09): : 501 - &
  • [7] CONTRIBUTION TO RESEARCH ON CELLULOSE DIACETATE AS A SOLID-STATE TRACK DETECTOR
    DECOSSAS, JL
    MOLITON, JP
    VAREILLE, JC
    TEYSSIER, JL
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1977, 34 (1-3): : 61 - 65
  • [8] ON THE USE OF CELLULOSE NITRATE AS SOLID-STATE NUCLEAR TRACK DETECTOR .1. DETECTOR PREPARATION AND ETCHING BEHAVIOR
    LUCK, HB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 212 (1-3): : 479 - 482
  • [9] APPLICATION OF SOLID-STATE NUCLEAR TRACK DETECTOR IN NEUTRON DOSIMETRY
    LI, HT
    ZHU, TC
    XIE, YR
    XIE, JL
    DEXI, J
    HUANG, CG
    XU, SK
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 371 - 372
  • [10] SOLID-STATE NUCLEAR TRACK DETECTOR APPLICATION TO BIOLOGIC RADIOAUTOGRAPHY
    ESCHENBR.AB
    FEDERATION PROCEEDINGS, 1969, 28 (02) : 295 - &