Design and performance studies of a hybrid voltage regulator with improved energy efficiency

被引:2
|
作者
Panguloori, R. B. [1 ]
Kastha, D. [1 ]
Patra, A. [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Kharagpur 721302, W Bengal, India
关键词
BUCK CONVERTER; TRANSIENT;
D O I
10.1049/iet-pel.2010.0001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Transformer coupling in high step-down ratio voltage regulators (VR) improves their efficiency by extending the duty cycle, but re wits in poor dynamic performance because of their low inductor current slew rate and the leakage inductance of the transformer. Hybrid VR use an auxiliary buck converter in parallel with the main converter during load transients to improve the dynamic performance of the VR. The dynamic power loss in the auxiliary buck converter, however, severely affects the energy efficiency of the VR with increasing frequency of the load transients. This study presents the design and performance of a new control circuit proposed to minimise the dynamic power loss in the auxiliary buck converter of a hybrid voltage regulator consisting of an isolated full-bridge current doubler rectifier converter in parallel with an auxiliary buck converter. The results obtained from simulation and experimentation on a 9-19 V input, 1 V/30 A output, 500 kHz hybrid voltage regulator. designed according to the proposed method, show that the proposed control scheme significantly improves both the dynamic performance and the energy efficiency of the VR.
引用
收藏
页码:915 / 924
页数:10
相关论文
共 50 条
  • [1] Analysis and design of Voltage Regulator with improved light load efficiency
    Abu Qahouq, Jaber A.
    Huang, Lilly
    2006 IEEE International Conference on Acoustics, Speech and Signal Processing, Vols 1-13, 2006, : 3603 - 3606
  • [2] Design of a Switch Mode AC Voltage Regulator with Improved Performance
    Ahmed, Md. Raju
    Alam, M. J.
    INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONIC S, 2006, : 203 - +
  • [3] Analysis and design of voltage regulator with adaptive FET modulation scheme and improved efficiency
    不详
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (02) : 896 - 906
  • [4] Design of a Redundant Paralleled Voltage Regulator Module System with Improved Efficiency and Dynamic Response
    Mishra, Santanu K.
    Zhou, Steve
    Huang, Wenkang
    Schuellein, George
    CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 2524 - 2528
  • [5] Design of Hybrid Controller for Automatic Voltage Regulator
    Bal, Gungor
    Ozturk, Nihat
    Oncu, Selim
    Unal, Kenan
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2023, 26 (01): : 199 - 207
  • [6] High-Efficiency High Voltage Hybrid Charge Pump Design With an Improved Chip Area
    Abaravicius, Bartas
    Cochran, Sandy
    Mitra, Srinjoy
    IEEE ACCESS, 2021, 9 : 94386 - 94397
  • [7] Novel temporal zone plate design with improved energy efficiency and noise performance
    Li, Bo
    Lou, Shuqin
    Azana, Jose
    2014 IEEE PHOTONICS CONFERENCE (IPC), 2014, : 366 - 367
  • [8] Improved light-load efficiency for synchronous rectifier voltage regulator module
    Zhou, XW
    Donati, M
    Amoroso, L
    Lee, FC
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (05) : 826 - 834
  • [9] Analysis and design of voltage regulator with adaptive FET modulation to improve efficiency
    Abdel-Rahman, Osama
    Abu-Qahouq, Jaber
    Huang, Lilly
    Batarseh, Issa
    APEC 2007: TWENTY-SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 2007, : 1544 - +
  • [10] HYBRID VOLTAGE REGULATOR FOR AUTOMOBILES
    SAWAMURA, A
    TAKAHASHI, T
    DENDA, SI