Selection of internal fixation method for femoral intertrochanteric fractures using a finite element method

被引:10
|
作者
Mu, Jia-Xuan [1 ]
Xiang, Shi-Yang [1 ]
Ma, Qing-Yu [1 ]
Gu, Hai-Lun [1 ]
机构
[1] China Med Univ, Shengjing Hosp, Dept Orthoped, 36 Sanhao St, Shenyang 117004, Liaoning, Peoples R China
关键词
Hip fractures; Fracture fixation; Intramedullary; Finite element analysis; HIP-FRACTURES; UNITED-STATES; FORCES; FEMUR; WIRE; NAIL; WALL;
D O I
10.12998/wjcc.v9.i22.6343
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Failure to fix unstable intertrochanteric fractures impairs return to daily activities. AIM To simulate five different internal fixation methods for unstable proximal femoral fractures. METHODS A three-dimensional model of the femur was established from sectional computed tomography images, and an internal fixation model was established. Finite element analysis of the femur model was established, and three intertrochanteric fracture models, medial defect, lateral defect, and medial-lateral defects, were simulated. Displacement and stress distribution after fixation with a proximal femoral anti-rotation intramedullary nail (PFNA), integrated dual-screw fixation (ITN), PFNA + wire, PFNA + plate, and PFNA + wire + plate were compared during daily activities. RESULTS The maximum displacement and stress of PFNA and ITN were 3.51 mm/473 MPa and 2.80 mm/588 MPa for medial defects; 2.55 mm/288 MPa and 2.10 mm/307 MPa for lateral defects; and 3.84 mm/653 MPa and 3.44 mm/641 MPa for medial-lateral defects, respectively. For medial-lateral defects, reconstructing the medial side alone changed the maximum displacement and stress to 2.79 mm/515 MPa; reconstructing the lateral side changed them to 3.72 mm/608 MPa, when both sides were reconstructed, they changed to 2.42 mm/309 MPa. CONCLUSION For medial defects, intramedullary fixation would allow early low-intensity rehabilitation exercise, and ITN rather than PFNA reduces the risk of varus and cut-out; for lateral wall defects or weakness, intramedullary fixation allows higher-intensity rehabilitation exercise, and ITN reduces the risk of varus. For both medial and lateral defects, intramedullary fixation alone will not allow early functional exercise, but locating lateral or medial reconstruction will. For defects in both the inner and outer sides, if reconstruction cannot be completed, ITN is more stable.
引用
收藏
页码:6343 / 6356
页数:14
相关论文
共 50 条
  • [1] Selection of internal fixation method for femoral intertrochanteric fractures using a finite element method
    Jia-Xuan Mu
    Shi-Yang Xiang
    Qing-Yu Ma
    Hai-Lun Gu
    World Journal of Clinical Cases, 2021, (22) : 6343 - 6356
  • [2] Biomechanical Study Using the Finite Element Method of Internal Fixation in Pauwels Type III Vertical Femoral Neck Fractures
    Noda, Mitsuaki
    Saegusa, Yasuhiro
    Takahashi, Masayasu
    Tezuka, Daichi
    Adachi, Kazuhiko
    Naoi, Kazuya
    ARCHIVES OF TRAUMA RESEARCH, 2015, 4 (03)
  • [3] Finite element analysis of fixation stability according to reduction position for internal fixation of intertrochanteric fractures
    Kim, Cheol-Jeong
    Lee, Jung Sub
    Goh, Tae Sik
    Shin, Won Chul
    Lee, Chiseung
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [4] Fixation of Intertrochanteric Femoral Fractures
    Vecsei, Vilmos
    Hajdu, Stefan
    EUROPEAN INSTRUCTIONAL LECTURES, VOL 9, 2009, 2009, 9 : 91 - 96
  • [5] Internal fixation for intertrochanteric fractures
    Taylor, GM
    Neufeld, AJ
    Janzen, J
    JOURNAL OF BONE AND JOINT SURGERY, 1944, 26 : 707 - 712
  • [6] INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION
    DAVIS, TRC
    SHER, JL
    HORSMAN, A
    SIMPSON, M
    PORTER, BB
    CHECKETTS, RG
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01): : 26 - 31
  • [7] Biomechanical consideration of total hip arthroplasty following failed fixation of femoral intertrochanteric fractures - A finite element analysis
    Chen, Dave W.
    Lin, Chun-Li
    Hu, Chih-Chien
    Tsai, Ming-Feng
    Lee, Mel S.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (05) : 569 - 575
  • [8] PROXIMAL FEMORAL NAIL ANTIROTATION INTERNAL FIXATION IN TREATING INTERTROCHANTERIC FEMORAL FRACTURES OF ELDERLY SUBJECTS
    Jia, L.
    Zhang, K.
    Wang, Z. G.
    Wang, L.
    Yang, S. Y.
    Zheng, Y. P.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2017, 31 (02): : 329 - 334
  • [9] The biomechanical comparison of screw fixation and cross pinning methods in salter harris type 2 distal femoral fractures using the finite element method Fixation biomechanics in pediatric distal femoral fractures
    Oner, Kerim
    Ozer, Alaettin
    Paksoy, Ahmet Emre
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2021, 12 : 205 - 209
  • [10] Study of the effect of fixation plates in proximal tibia fractures using the finite element method
    Zambrano, Lilibeth A.
    Müller-Karger, Carmen