Simple, fast and reliable perfusion monitoring of microvascular flaps

被引:27
|
作者
Meier, J. K. [2 ]
Prantl, L. [1 ]
Mueller, S. [2 ]
Moralis, A. [2 ]
Liebsch, G. [3 ]
Gosau, M. [2 ]
机构
[1] Univ Med Ctr, Ctr Plast Hand & Reconstruct Surg, D-93042 Regensburg, Germany
[2] Univ Med Ctr, Dept Craniomaxillofacial Surg, D-93042 Regensburg, Germany
[3] PreSens GmbH, Regensburg, Germany
关键词
Free flap; microvascular; pO(2) imaging; fluorescent optical sensor; TISSUE TRANSFER; OXYGEN FLUX; HEAD; NECK; RECONSTRUCTION; COMPLICATIONS; THROMBOSIS;
D O I
10.3233/CH-2011-1439
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Free tissue transfer in head and neck reconstructions has a very high success rate, but thrombotic vessel occlusion is still a serious complication occurring in up to 10% of all cases. Thus, a simple, fast and reliable monitoring system for free flaps would be of advantage. Objective: The aim of this study was to investigate whether free flap monitoring by measuring perfusion-dependent parameters is a suitable method for discovering vessel thrombosis in free flaps. Methods: 10 patients requiring tissue reconstruction after tumour surgery or because of chronic wounds were included in this study. 10 microvascular flaps were harvested and transplanted. Perfusion was determined by measuring a fluorescent oxygen sensor foil covering the flap's skin surface by means of a USB-handheld fluorescence microscope prototype. The sensor contained an oxygen reservoir which was consumed by the tissue corresponding to the perfusion status of the flap. Measurements were done before explantation, after successful anastomosis and 1 day after surgery. Results: Clinically well-perfused grafts showed slope values between 0.07 and 0.27 (mean: 0.18+/-0.07), and clinically poorly perfused grafts showed slope values between 0.35 and 0.75 (mean: 0.52+/-0.19). In the present study, we used a threshold slope value of 0.3 for differentiating between well-perfused and poorly perfused flaps. Conclusion: Flap monitoring via oxygen imaging by means of fluorescent sensor foils appears to be a fast, non-invasive, cost-effective and thus suitable method for analyzing flap perfusion with the additional advantage of aiding decision making on flap revision.
引用
收藏
页码:13 / 24
页数:12
相关论文
共 50 条
  • [1] Continuous intraoperative perfusion monitoring of free microvascular anastomosed fasciocutaneous flaps using remote photoplethysmography
    Sebastian P. Schraven
    Benjamin Kossack
    Daniel Strüder
    Maximillian Jung
    Lotte Skopnik
    Justus Gross
    Anna Hilsmann
    Peter Eisert
    Robert Mlynski
    Eric L. Wisotzky
    Scientific Reports, 13 (1)
  • [2] Comparison of Hyperspectral Imaging and Microvascular Doppler for Perfusion Monitoring of Free Flaps in an In Vivo Rodent Model
    Becker, Philipp
    Blatt, Sebastian
    Pabst, Andreas
    Heimes, Diana
    Al-Nawas, Bilal
    Kaemmerer, Peer W.
    Thiem, Daniel G. E.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (14)
  • [3] Continuous intraoperative perfusion monitoring of free microvascular anastomosed fasciocutaneous flaps using remote photoplethysmography
    Schraven, Sebastian P.
    Kossack, Benjamin
    Strueder, Daniel
    Jung, Maximillian
    Skopnik, Lotte
    Gross, Justus
    Hilsmann, Anna
    Eisert, Peter
    Mlynski, Robert
    Wisotzky, Eric L.
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [4] Microdialysis detects postoperative perfusion failure in microvascular flaps
    Setälä, L
    Papp, A
    Romppanen, EL
    Mustonen, P
    Berg, L
    Härmä, M
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2006, 22 (02) : 87 - 95
  • [5] POSTOPERATIVE MONITORING AND SALVAGE OF MICROVASCULAR FREE FLAPS
    STEPNICK, DW
    HAYDEN, RE
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 1994, 27 (06) : 1201 - 1217
  • [6] TISSUE PH MONITORING IN MICROSURGERY - A PRELIMINARY EVALUATION OF CONTINUOUS TISSUE PH MONITORING AS AN INDICATOR OF PERFUSION DISTURBANCES IN MICROVASCULAR FREE FLAPS
    RASKIN, DJ
    ERK, Y
    SPIRA, M
    MELISSINOS, EG
    ANNALS OF PLASTIC SURGERY, 1983, 11 (04) : 331 - 339
  • [7] Simple monitoring technique for muscle flaps
    Dagum, AB
    Dowd, AJ
    MICROSURGERY, 1995, 16 (11) : 728 - 729
  • [8] Current Techniques for Postoperative Monitoring of Microvascular Free Flaps
    Khatri, Nasir
    Zhang, Shuhao
    Kale, Santosh S.
    JOURNAL OF WOUND OSTOMY AND CONTINENCE NURSING, 2017, 44 (02) : 148 - 152
  • [9] INFLUENCE OF KETAMINE AND PENTOBARBITAL ON MICROVASCULAR PERFUSION IN NORMAL SKIN AND SKIN FLAPS
    UHL, E
    SIRSJO, A
    NILSSON, G
    NYLANDER, G
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1994, 14 (05): : 308 - 312
  • [10] The venous flaps: an experimental study of the microvascular architecture, the area of perfusion and their correlation
    Krishnan, KG