Cavitation effect of holmium laser pulse applied to ablation of hard tissue underwater

被引:27
|
作者
Lue, Tao [1 ,3 ]
Xiao, Qing [2 ]
Xia, Danqing [1 ]
Ruan, Kai [1 ]
Li, Zhengjia [1 ]
机构
[1] Huazhong Univ Sci & Technol, Coll Optoelect Sci & Engn, Wuhan Natl Lab Optoelect, Wuhan 430074, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Britton Chance Ctr Biomed Photon, Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
[3] China Univ Geosci, Sch Math & Phys, Wuhan 430074, Peoples R China
关键词
holmium laser pulse; cavitation bubble; acoustic transient; laser-tissue interaction; optical coherent microscopy system; NANOSECOND OPTICAL-BREAKDOWN; INDUCED PRESSURE WAVES; BUBBLE FORMATION; SHOCK-WAVES; HO-YAG; CALCULUS RETROPULSION; WATER; DYNAMICS; LITHOTRIPSY; DURATION;
D O I
10.1117/1.3470092
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To overcome the inconsecutive drawback of shadow and schlieren photography, the complete dynamics of cavitation bubble oscillation or ablation products induced by a single holmium laser pulse [2.12 mu m, 300 mu s (FWHM)] transmitted in different core diameter (200, 400, and 600 mu m) fibers is recorded by means of highspeed photography. Consecutive images from high-speed cameras can stand for the true and complete process of laser-water or laser-tissue interaction. Both laser pulse energy and fiber diameter determine cavitation bubble size, which further determines acoustic transient amplitudes. Based on the pictures taken by high-speed camera and scanned by an optical coherent microscopy (OCM) system, it is easily seen that the liquid layer at the distal end of the fiber plays an important role during the process of laser-tissue interaction, which can increase ablation efficiency, decrease heat side effects, and reduce cost. c 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3470092]
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Cavitation effect of pulsed holmium laser and dynamic characteristics of hard tissue ablation underwater
    Lü T.
    Xiao Q.
    Li Z.
    Guangxue Xuebao/Acta Optica Sinica, 2010, 30 (12): : 3558 - 3562
  • [2] Underwater holmium-laser-pulse-induced complete cavitation bubble movements and acoustic transients
    Lue Tao
    Li ZhengJia
    CHINESE SCIENCE BULLETIN, 2011, 56 (12): : 1226 - 1229
  • [3] Underwater holmium-laser-pulse-induced complete cavitation bubble movements and acoustic transients
    Lü Tao1
    2 School of Mathematics and Physics
    Science Bulletin, 2011, (12) : 1226 - 1229
  • [4] The True Ablation Effect of Holmium YAG Laser on Soft Tissue
    Emiliani, Esteban
    Talso, Michele
    Haddad, Mattieu
    Pouliquen, Christelle
    Derman, Jonathan
    Cote, Jean-Francois
    Doizi, Steeve
    Millan, Felix
    Berthe, Laurent
    Audouin, Marie
    Traxer, Olivier
    JOURNAL OF ENDOUROLOGY, 2018, 32 (03) : 230 - 235
  • [5] The effects of water-mediated cavitation on hard tissue ablation with Ho: YAG laser
    Cai, Jiahui
    Lv, Mingxuan
    Yun, Hui
    Shi, Xiaowei
    Zhang, Xianzeng
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VIII, 2018, 10820
  • [6] Ultra-Short Pulse Laser Ablation of Biological Hard Tissue and Biocompatibles
    Strassl, Martin
    Wieger, Verena
    Brodoceanu, Daniel
    Beer, Franziska
    Moritz, Andreas
    Wintner, Ernst
    JOURNAL OF LASER MICRO NANOENGINEERING, 2008, 3 (01): : 30 - 40
  • [7] Characterization of tissue ablation with a continuous wave holmium laser
    Domankevitz, Y
    McMillan, K
    Nishioka, NS
    LASERS IN SURGERY AND MEDICINE, 1996, 19 (01) : 97 - 102
  • [8] Ultrashort pulse lasers for hard tissue ablation
    Neev, J
    DaSilva, LB
    Feit, MD
    Perry, MD
    Rubenchik, AM
    Stuart, BC
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1996, 2 (04) : 790 - 800
  • [9] Ultrashort pulse lasers for hard tissue ablation
    Univ of California, Irvine, United States
    IEEE J Sel Top Quantum Electron, 4 (790-799):
  • [10] HOLMIUM-YAG LASER ABLATION OF VASCULAR TISSUE
    KOPCHOK, GE
    WHITE, RA
    TABBARA, M
    SAADATMANESH, V
    PENG, SK
    LASERS IN SURGERY AND MEDICINE, 1990, 10 (05) : 405 - 413