Analysis of patient movement during 3D USCT data acquisition

被引:6
|
作者
Ruiter, N. V. [1 ]
Hopp, T. [1 ]
Zapf, M. [1 ]
Kretzek, E. [1 ]
Gemmeke, H. [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Data Proc & Elect, D-76021 Karlsruhe, Germany
关键词
Ultrasound computer tomography; patient movement;
D O I
10.1117/12.2216680
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In our first clinical study with a full 3D Ultrasound Computer Tomography (USCT) system patient data was acquired in eight minutes for one breast. In this paper the patient movement during the acquisition was analyzed quantitatively and as far as possible corrected in the resulting images. The movement was tracked in ten successive reflectivity reconstructions of full breast volumes acquired during 10 s intervals at different aperture positions, which were separated by 41 s intervals. The mean distance between initial and final position was 2.2 mm (standard deviation (STD) +/- 0.9 mm, max. 4.1 mm, min. 0.8 mm) and the average sum of all moved distances was 4.9 mm (STD +/- 1.9 mm, max. 8.8 mm, min. 2.7 mm). The tracked movement was corrected by summing successive images, which were transformed according to the detected movement. The contrast of these images increased and additional image content became visible.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Evaluation of the Reconfiguration of the Data Acquisition System for 3D USCT
    Birk, Matthias
    Hagner, Clemens
    Balzer, Matthias
    Ruiter, Nicole V.
    Huebner, Michael
    Becker, Juergen
    INTERNATIONAL JOURNAL OF RECONFIGURABLE COMPUTING, 2011, 2011
  • [2] Realization of an optimized 3D USCT
    Ruiter, Nicole V.
    Goebel, Georg
    Berger, Lutz
    Zapf, Michael
    Gemmeke, Hartmut
    MEDICAL IMAGING 2011: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2011, 7968
  • [3] A prototype system for acquisition and analysis of 3D mandibular movement
    Santos I.C.T.
    Tavares J.M.R.S.
    Mendes J.
    Paulo M.P.F.
    International Journal of Mechanics and Materials in Design, 2008, 4 (2) : 173 - 180
  • [4] THE ACQUISITION AND STATISTICAL ANALYSIS OF RAPID 3D FMRI DATA
    Lindquist, Martin A.
    Zhang, Cun-Hui
    Glover, Gary
    Shepp, Lawrence
    STATISTICA SINICA, 2008, 18 (04) : 1395 - 1419
  • [5] Fast Detection of Breast Position for 3D USCT
    Qin, Bo
    Zapf, Michael
    Kretzek, Ernst
    Ma, Xiaochuan
    Ruiter, Nicole V.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1896 - 1899
  • [6] A system for the acquisition and analysis of the 3D mandibular movement to be used in dental medicine
    T. Santos, Isa C.
    R. S. Tavares, Joao Manuel
    Mendes, Joaquim
    F. Paulo, Manuel P.
    COMPUTATIONAL MODELLING OF OBJECTS REPRESENTED IN IMAGES: FUNDAMENTALS, METHODS AND APPLICATIONS, 2007, : 399 - +
  • [7] Phantom image results of an optimized full 3D USCT
    Ruiter, Nicole V.
    Zapf, Michael
    Hopp, Torsten
    Dapp, Robin
    Gemmeke, Hartmut
    MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320
  • [8] Wave Equation Based Simulation Of 3D Field In USCT
    Rolecek, J.
    Hemzal, D.
    Jan, J.
    Peterlik, I
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2008, : 545 - 550
  • [9] ACQUISITION OF 3D DATA IN GIS ENVIRONMENT
    Franco, Antonio Sousa
    Marques, Ana
    Dias, Jose
    ATAS DAS I JORNADAS LUSOFONAS DE CIENCIAS E TECNOLOGIAS DE INFORMACAO GEOGRAFICA, 2015, : 210 - 220
  • [10] Realization of an pseudo-randomly sampled 3D USCT
    Zapf, M.
    Hopp, T.
    Gemmeke, H.
    Angerer, M.
    Lu, Z.
    Molchanova, O.
    Rashvand, N.
    Blanco, R.
    Steck, P.
    Leyrer, B.
    Tcherniakhovski, D.
    Bormann, D.
    Schlote-Holubek, K.
    Ruiter, N., V
    MEDICAL IMAGING 2022: ULTRASONIC IMAGING AND TOMOGRAPHY, 2022, 12038