Quantifying the degradation of degradable implants and bone formation in the femoral condyle using micro-CT 3D reconstruction

被引:17
|
作者
Xu, Yichi [1 ,2 ]
Meng, Haoye [1 ,2 ,3 ]
Yin, Heyong [1 ,2 ]
Sun, Zhen [1 ,2 ]
Peng, Jiang [1 ,2 ]
Xu, Xiaolong [1 ,2 ]
Guo, Quanyi [1 ,2 ]
Xu, Wenjing [1 ,2 ]
Yu, Xiaoming [1 ,2 ]
Yuan, Zhiguo [1 ,2 ]
Xiao, Bo [1 ,2 ]
Wang, Cheng [1 ,2 ]
Wang, Yu [1 ,2 ]
Liu, Shuyun [1 ,2 ]
Lu, Shibi [1 ,2 ]
Wang, Zhaoxu [4 ]
Wang, Aiyuan [1 ,2 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Inst Orthoped, 28 Fuxing Rd, Beijing 100853, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Key Lab Musculoskeletal Trauma & War Injuries, Beijing 100853, Peoples R China
[3] Univ Sci & Technol Beijing, Sch Mat Sci & Engn, Beijing 100083, Peoples R China
[4] Chinese Natl Inst Food & Drug Control, Testing Dept Biomat & Tissue Engn Prod, 2 Tiantan Xili, Beijing 100050, Peoples R China
基金
美国国家科学基金会;
关键词
micro-computed tomography; magnesium alloy; degradation; bone formation; in vivo; ARC-OXIDIZED MAGNESIUM; IN-VIVO DEGRADATION; ALLOYS; PERFORMANCE; BIOMATERIALS; OXIDATION; VITRO; MICROSTRUCTURE;
D O I
10.3892/etm.2017.5389
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Degradation limits the application of magnesium alloys, and evaluation methods for non-traumatic in vivo quantification of implant degradation and bone formation are imperfect. In the present study, a micro-arc-oxidized AZ31 magnesium alloy was used to evaluate the degradation of implants and new bone formation in 60 male New Zealand white rabbits. Degradation was monitored by weighing the implants prior to and following implantation, and by performing micro-computed tomography (CT) scans and histological analysis after 1, 4, 12, 24, 36, and 48 weeks of implantation. The results indicated that the implants underwent slow degradation in the first 4 weeks, with negligible degradation in the first week, followed by significantly increased degradation during weeks 12-24 (P<0.05), and continued degradation until the end of the 48-week experimental period. The magnesium content decreased as the implant degraded (P<0.05); however, the density of the material exhibited almost no change. Micro-CT results also demonstrated that pin volume, pin mineral density, mean 'pin thickness', bone surface/bone volume and trabecular separation decreased over time (P<0.05), and that the pin surface area/pin volume, bone volume fraction, trabecular thickness, trabecular number and tissue mineral density increased over time (P<0.05), indicating that the number of bones and density of new bone increased as magnesium degraded. These results support the positive effect of magnesium on osteogenesis. However, from the maximum inner diameter of the new bone loop and diameter of the pin in the same position, the magnesium alloy was not capable of creating sufficient bridges between the bones and biomaterials when there were preexisting gaps. Histological analyses indicated that there were no inflammatory responses around the implants. The results of the present study indicate that a micro-arc-oxidized AZ31 magnesium alloy is safe in vivo and efficiently degraded. Furthermore, the novel bone formation increased as the implant degraded. The findings concluded that micro-CT, which is useful for providing non-traumatic, in vivo, quantitative and precise data, has great value for exploring the degradation of implants and novel bone formation.
引用
收藏
页码:93 / 102
页数:10
相关论文
共 50 条
  • [1] 3D analysis of the trabecular bone using micro-CT
    Moon, HS
    Shim, WH
    Lim, BJ
    Kim, KD
    Kim, HJ
    Chung, MK
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B323 - B323
  • [2] Micro-CT for nondestructive 3D reconstruction of MEMS and sensors
    Sasov, A
    MEMS DESIGN, FABRICATION, CHARACTERIZATION, AND PACKAGING, 2001, 4407 : 388 - 394
  • [3] Micro-CT Guided 3D Reconstruction of Histological Images
    Nagara, Kai
    Roth, Holger R.
    Nakamura, Shota
    Oda, Hirohisa
    Moriya, Takayasu
    Oda, Masahiro
    Mori, Kensaku
    PATCH-BASED TECHNIQUES IN MEDICAL IMAGING (PATCH-MI 2017), 2017, 10530 : 93 - 101
  • [4] 3D micro-CT analysis of cancellous bone architecture
    Rossi, M
    Casali, F
    Romani, D
    Carabini, ML
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 349 - 358
  • [5] 3D analysis of bone formation around titanium implants using micro computed tomography (μCT)
    Bernhardt, Ricardo
    Scharnweber, Dieter
    Muller, Bert
    Beckmann, Felix
    Goebbels, Juergen
    Jansen, John
    Schliephake, Henning
    Worch, Hartmut
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [6] Micro-CT as a novel technique for 3D reconstruction of molluscan anatomy
    Golding, Rosemary E.
    Jones, Allan S.
    MOLLUSCAN RESEARCH, 2007, 27 (03) : 123 - 128
  • [7] Bone micro architectural changes in rheumatoid arthritis assessed by 3D micro-CT
    Garcia-Miguel, J.
    Wright, A.
    Perez-Edo, L.
    Blanche, J.
    Marinoso, M.
    Ciria, M.
    Carbone, J.
    Wehrli, F. W.
    BONE, 2007, 40 (06) : S259 - S259
  • [8] Modeling and Reconstruction of Micro-structured 3D Chitosan/Gelatin Porous Scaffolds Using Micro-CT
    Gong Haibo
    Li Dichen
    He Jiankang
    Liu Yaxiong
    Lian Qin
    Zhao Jinna
    NUMERICAL ANALYSIS AND APPLIED MATHEMATICS, 2008, 1048 : 244 - 248
  • [9] Reconstruction of the 3D Geometry of the Ossicular Chain Based on Micro-CT Imaging
    Kwacz, Monika
    Wysocki, Jaroslaw
    Krakowian, Piotr
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2012, 32 (01) : 27 - 40
  • [10] 3D visualization of human cortical bone remodeling spaces using micro-CT data
    Wei, Xuan
    Cooper, David M. L.
    AMERICAN JOURNAL OF BIOLOGICAL ANTHROPOLOGY, 2023, 180 : 192 - 192