Terahertz Time-Domain Spectroscopy of Ractopamine Hydrochloride

被引:1
|
作者
Chen Xi-ai [1 ,2 ]
Huang Ping-jie [1 ]
Hou Di-bo [1 ]
Kang Xu-sheng [1 ]
Zhang Guang-xin [1 ]
Zhou Ze-kui [1 ]
机构
[1] Zhejiang Univ, State Key Lab Ind Control Technol, Dept Control Sci & Engn, Hangzhou 310027, Peoples R China
[2] China Jiliang Univ, Sch Mech & Elect Engn, Hangzhou 310018, Peoples R China
关键词
Terahertz spectroscopy; Ractopamine; Absorption coefficient; Density; CLENBUTEROL;
D O I
10.3964/j.issn.1000-0593(2011)03-0600-04
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The terahertz spectra of Ractopamine hydrochloride in the range of 0.2 to 2.2 THz was obtained by THz time-domain spectroscopy, and the absorption and refraction spectra of Ractopamine hydrochloride was got meanwhile. The structure and vibrational frequencies of Ractopamine molecule in the THz range were simulated by density functional theory. The difference between experimental and theoretical results was analyzed. And assisted by Gaussian View3.09, the origin of the vibrational frequencies was recognized. The results show that besides the intramolecular vibrations, TFIz absorption of Ractopamine hydrochloride originated from the intermolecular hydrogen bond network and Van der Waals force between molecules. This study demonstrated the feasibility of time-domain terahertz spectroscopy for the identification of Ractopamine hydrochloride and provided a new way for the detection of Ractopamine hydrochloride.
引用
收藏
页码:600 / 603
页数:4
相关论文
共 8 条
  • [1] Assignment of the lowest-lying THz absorption signatures in biotin and lactose monohydrate by solid-state density functional theory
    Allis, D. G.
    Fedor, A. M.
    Korter, T. M.
    Bjarnason, J. E.
    Brown, E. R.
    [J]. CHEMICAL PHYSICS LETTERS, 2007, 440 (4-6) : 203 - 209
  • [2] Determination of ractopamine and clenbuterol in feeds by gas chromatography-mass spectrometry
    He, Limin
    Su, Yijuan
    Zeng, Zhenling
    Liu, Yahong
    Huang, Xianhui
    [J]. ANIMAL FEED SCIENCE AND TECHNOLOGY, 2007, 132 (3-4) : 316 - 323
  • [3] Development of a label-free electrochemical immunosensor based on carbon nanotube for rapid determination of clenbuterol
    He, Pingli
    Wang, Zongyi
    Zhang, Liying
    Yang, Wenjun
    [J]. FOOD CHEMISTRY, 2009, 112 (03) : 707 - 714
  • [4] High-resolution waveguide THz spectroscopy of biological molecules
    Laman, N.
    Harsha, S. Sree
    Grischkowsky, D.
    Melingery, Joseph S.
    [J]. BIOPHYSICAL JOURNAL, 2008, 94 (03) : 1010 - 1020
  • [5] THz spectrum of monodeuterated methane
    Lattanzi, Valerio
    Walters, Adam
    Pearson, John C.
    Drouin, Brian J.
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2008, 109 (04): : 580 - 586
  • [6] Simultaneous detection for three kinds of veterinary drugs: Chloramphenicol, clenbuterol and 17-beta-estradiol by high-throughput suspension array technology
    Liu, Nan
    Su, Pu
    Gao, Zhixian
    Zhu, Maoxiang
    Yang, Zhihua
    Pan, Xiujie
    Fang, Yanjun
    Chao, Fuhuan
    [J]. ANALYTICA CHIMICA ACTA, 2009, 632 (01) : 128 - 134
  • [7] Lucie N., 2009, ANAL CHIM ACTA, V656, P8
  • [8] Independent determination of the complex refractive index and wave impedance by time-domain terahertz spectroscopy
    Nemec, H
    Kadlec, F
    Kuzel, P
    Duvillaret, L
    Coutaz, JL
    [J]. OPTICS COMMUNICATIONS, 2006, 260 (01) : 175 - 183