Real-time cylindrical curvilinear 3-D ultrasound imaging

被引:2
|
作者
Pua, EC [1 ]
Yen, JT [1 ]
Smith, SW [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
关键词
2-D array; curvilinear; cylindrical; endoscopic; real-time; transesophageal; volumetric;
D O I
10.1177/016173460302500302
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In patients who are obese or exhibit signs of pulmonary disease, standard transthoracic scanning may yield poor quality cardiac images. For these conditions, two-dimensional transesophageal echocardiography (TEE) is established as an essential diagnostic tool. Current techniques in transesophageal scanning, though, are limited by incomplete visualization of cardiac structures in close proximity to the transducer. Thus, we propose a 2D curvilinear array for 3D transesophageal echocardiography in order to widen the field of view and increase visualization close to the transducer face. In this project, a 440 channel 5 MHz two-dimensional array with a 12.6 mm aperture diameter on a flexible interconnect circuit has been molded to a 4 mm radius of curvature. A 75% element yield was achieved during fabrication and an average -6dB bandwidth of 30% was observed in pulse-echo tests. Using this transducer in conjunction with modifications to the beam former delay software and scan converter display software of the our 3D scanner, we obtained cylindrical real-time curvilinear volumetric scans of tissue phantoms, including a field of view of greater than 120degrees in the curved, azimuth direction and 65degrees phased array sector scans in the elevation direction. These images were achieved using a stepped subaperture across the cylindrical curvilinear direction of the transducer face and phased array sector scanning in the noncurved plane. In addition, real-time volume rendered images of a tissue mimicking phantom with holes ranging from 1 cm to less than 4 mm have been obtained. 3D color flow Doppler results have also been acquired. This configuration can theoretically achieve volumes displaying 180degrees by 120.degrees The transducer is also capable of obtaining images through a curvilinear stepped subaperture in azimuth in conjunction with a rectilinear stepped subaperture in elevation, further increasing the field of view close to the transducer face. Future work includes development of an array for adapting these modifications to a 6 mm diameter endoscope probe.
引用
收藏
页码:137 / 150
页数:14
相关论文
共 50 条
  • [1] Real-time cylindrical curvilinear 3-D ultrasound imaging
    Pua, EC
    Yen, JT
    Smith, SW
    [J]. 2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 668 - 671
  • [2] Feasibility study: Real-time 3-D ultrasound imaging of the brain
    Smith, SW
    Chu, K
    Idriss, SF
    Ivancevich, NM
    Light, ED
    Wolf, PD
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (10): : 1365 - 1371
  • [3] Adaptive scan sequence for real-time ultrasound 3-D imaging
    Hashimoto, H
    Takeuchi, Y
    [J]. ULTRASONIC IMAGING, 2003, 25 (04) : 215 - 225
  • [4] Real-time 3-D ladar imaging
    Cho, Peter
    Anderson, Hyrum
    Hatch, Robert
    Ramaswami, Prem
    [J]. PROCEEDINGS OF THE HPCMP USERS GROUP CONFERENCE 2006, 2006, : 321 - 326
  • [5] Real-time 3D ultrasound imaging
    Ponomaryov, VI
    Sansores-Pech, R
    Gallegos-Funes, F
    [J]. Real-Time Imaging IX, 2005, 5671 : 19 - 29
  • [6] Passive Markers for Tracking Surgical Instruments in Real-Time 3-D Ultrasound Imaging
    Stoll, Jeffrey
    Ren, Hongliang
    Dupont, Pierre E.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (03) : 563 - 575
  • [7] Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming
    Lockwood, GR
    Talman, JR
    Brunke, SS
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) : 980 - 988
  • [8] ELECTRONIC 3-D REAL-TIME IMAGING OF COLONOSCOPY
    WILLIAMS, CB
    GUY, CN
    GILLIES, DF
    SAUNDERS, BP
    [J]. GASTROINTESTINAL ENDOSCOPY, 1993, 39 (02) : 345 - 345
  • [9] Real-time 3-D ultrasound guidance of interventional devices
    Light, Edward D.
    Angle, John F.
    Smith, Stephen W.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (09) : 2066 - 2078
  • [10] Real-time, 3-D ultrasound with multiple transducer arrays
    Fronheiser, MP
    Light, ED
    Idriss, SF
    Wolf, PD
    Smith, SW
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (01) : 100 - 105