Up to 10 year follow-up of the Oxford Domed Lateral Partial Knee Replacement from an independent centre

被引:19
|
作者
Newman, Simon D. S. [1 ]
Altuntas, Altay [2 ]
Alsop, Helen [1 ]
Cobb, Justin P. [1 ]
机构
[1] Imperial Coll London, MSk Lab, London, England
[2] Univ Melbourne, St Vincents Hosp, Fitzroy, Vic, Australia
来源
KNEE | 2017年 / 24卷 / 06期
关键词
Lateral osteoarthritis; Unicompartmental knee arthroplasty; Functional outcomes; Valgus alignment; NATIONAL JOINT REGISTRY; MATCHED PATIENTS; ARTHROPLASTY; OUTCOMES; GAIT; OSTEOARTHRITIS; DISLOCATION; ENGLAND; WALES;
D O I
10.1016/j.knee.2017.05.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The Oxford Domed Lateral Partial Knee Replacement (ODLPKR) was designed specifically for the lateral compartment in response to the unacceptable dislocation rate seen with the Oxford Partial Knee. This paper presents the up to 10-year follow-up of an independent, single surgeon series using this implant. The aim of this study is to assess the medium term outcome of the ODLPICR. The primary outcome measures were 13 revision surgery, re-operation and functional outcome. Methods: Sixty-four knees in 58 patients were performed between 2005 and 2009. Patients were interviewed by telephone to determine whether further surgery had been conducted on their knee and to complete an Oxford Knee Score (OKS) questionnaire. Results: The status of 61 knees was confirmed with a median follow-up period of 84 months. One patient sustained two bearing dislocations ultimately requiring an elective bearing exchange. Two knees underwent revision to TKR and five other patients reported further operations. Median OKS was 26 (range nine to 36)pre-operatively and 42 (10-48) at final follow-up. Conclusion: The ODLPKR offers an effective and safe treatment for lateral compartment osteoarthritis. Bearing dislocation does not appear to be a significant issue with this implant and implant retention is similar to that achieved by medial unicompartmental knee replacements in the medium term. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1414 / 1421
页数:8
相关论文
共 50 条
  • [1] Up to twelve year follow-up of the Oxford phase three unicompartmental knee replacement in China: seven hundred and eight knees from an independent centre
    Huaming Xue
    Yihui Tu
    Tong Ma
    Tao Wen
    Tao Yang
    Minwei Cai
    [J]. International Orthopaedics, 2017, 41 : 1571 - 1577
  • [2] Up to twelve year follow-up of the Oxford phase three unicompartmental knee replacement in China: seven hundred and eight knees from an independent centre
    Xue, Huaming
    Tu, Yihui
    Ma, Tong
    Wen, Tao
    Yang, Tao
    Cai, Minwei
    [J]. INTERNATIONAL ORTHOPAEDICS, 2017, 41 (08) : 1571 - 1577
  • [3] Up to 10-Year Follow-Up of the Oxford Medial Partial Knee Arthroplasty-695 Cases From a Single Institution
    Kristensen, Per W.
    Holm, Henriette A.
    Varnum, Claus
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (09): : 195 - 198
  • [4] Cementless Oxford medial unicompartimental knee replacement: an independent series with a 5-year-follow-up
    Benjamin Panzram
    Ines Bertlich
    Tobias Reiner
    Tilman Walker
    Sébastien Hagmann
    Tobias Gotterbarm
    [J]. Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1011 - 1017
  • [5] Cementless Oxford medial unicompartimental knee replacement: an independent series with a 5-year-follow-up
    Panzram, Benjamin
    Bertlich, Ines
    Reiner, Tobias
    Walker, Tilman
    Hagmann, Sebastien
    Gotterbarm, Tobias
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (07) : 1011 - 1017
  • [6] The Oxford unicompartmental knee prosthesis: a 5-year follow-up
    Vorlat, P
    Verdonk, R
    Schauvlieghe, H
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2000, 8 (03) : 154 - 158
  • [7] The Oxford unicompartmental knee prosthesis: a 2–14 year follow-up
    R. Verdonk
    D. Cottenie
    K. F. Almqvist
    P. Vorlat
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2005, 13 : 163 - 166
  • [8] The Oxford unicompartmental knee prosthesis: a 5-year follow-up
    P. Vorlat
    R. Verdonk
    H. Schauvlieghe
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2000, 8 : 154 - 158
  • [9] TOTAL KNEE REPLACEMENT - A 6 TO 11 YEAR FOLLOW-UP
    VANVUREN, JP
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (03): : 447 - 448
  • [10] Unicompartmental knee arthroplasty: 10-year follow-up
    Bistolfi, A.
    Crova, M.
    Deledda, D.
    Paonessa, M.
    Cimino, A.
    Ravera, L.
    Massazza, G.
    [J]. MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2012, 63 (03) : 155 - 161