Flow injection amperometric enzyme biosensor for direct determination of organophosphate nerve agents

被引:94
|
作者
Mulchandani, P [1 ]
Chen, W [1 ]
Mulchandani, A [1 ]
机构
[1] Univ Calif Riverside, Dept Environm Chem & Engn, Riverside, CA 92521 USA
关键词
D O I
10.1021/es001773q
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A flow injection amperometric biosensor for the determination of organophosphate nerve agents was developed. The biosensor incorporated an immobilized enzyme reactor that contains the enzyme organophosphorus hydrolase covalently immobilized on activated aminopropyl controlled pore glass beads and an electrochemical flow-through detector containing carbon paste working electrode, a silver/silver chloride reference electrode, and stainless steel counter electrode. The organophosphorus hydrolase catalyzed the hydrolysis of organophosphate with nitrophenyl substituent to generate p-nitrophenol which is then detected downstream electrochemically at the carbon paste electrode poised at 0.9 V vs the reference electrode. The amperometric response of the biosensor was linear up to 120 muM and 140 muM, with lower detection limits of 20 nM and 20 nM, for paraoxon and methyl parathion, respectively. The response was very reproducible (RSD 2%, n = 35) and stable for over 1 month when the immobilized enzyme column was stored at 4 degreesC. Each assay took ca. 2 min giving a sample throughput of 30 h(-1). The applicability of the biosensor to monitor paraoxon and methyl parathion in distilled water and simulated well water was demonstrated.
引用
收藏
页码:2562 / 2565
页数:4
相关论文
共 50 条
  • [1] Fiber-optic enzyme biosensor for direct determination of organophosphate nerve agents
    Mulchandani, A
    Pan, ST
    Chen, W
    [J]. BIOTECHNOLOGY PROGRESS, 1999, 15 (01) : 130 - 134
  • [2] A potentiometric microbial biosensor for direct determination of organophosphate nerve agents
    Mulchandani, A
    Mulchandani, P
    Chauhan, S
    Kaneva, I
    Chen, W
    [J]. ELECTROANALYSIS, 1998, 10 (11) : 733 - 737
  • [3] Biosensor for direct determination of organophosphate nerve agents. 1. Potentiometric enzyme electrode
    Mulchandani, P
    Mulchandani, A
    Kaneva, I
    Chen, W
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (01): : 77 - 85
  • [4] Direct monitoring of organophosphorus nerve agents by amperometric enzyme biosensor.
    Mulchandani, A
    Mulchandani, P
    Kanifar, H
    Chen, W
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U789 - U790
  • [5] Highly sensitive and selective amperometric microbial biosensor for direct determination of p-nitrophenyl-substituted organophosphate nerve agents
    Lei, Y
    Mulchandani, P
    Wang, J
    Chen, W
    Mulchandani, A
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (22) : 8853 - 8857
  • [6] Field-deployable amperometric enzyme electrodes for direct monitoring of organophosphate nerve agents
    Mulchandani, A
    Mulchandani, P
    Chen, W
    Wang, J
    Chen, L
    [J]. ENZYMES IN ACTION: GREEN SOLUTIONS FOR CHEMICAL PROBLEMS, 2000, 33 : 287 - 296
  • [7] Biosensor based on self-assembling acetylcholinesterase on carbon nanotubes for flow injection/amperometric detection of organophosphate pesticides and nerve agents
    Liu, GD
    Lin, YH
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (03) : 835 - 843
  • [8] Amperometric enzyme biosensors for field monitoring of organophosphate nerve agents.
    Mulchandani, A
    Mulchandani, P
    Chan, W
    Wang, J
    Chen, L
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U120 - U120
  • [9] Whole cell-enzyme hybrid amperometric biosensor for direct determination of organophosphorous nerve agents with p-nitrophenyl substituent
    Lei, Y
    Mulchandani, P
    Chen, W
    Wang, J
    Mulchandani, A
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2004, 85 (07) : 706 - 713
  • [10] Flow injection amperometric detection of OP nerve agents based on an organophosphorus-hydrolase biosensor detector
    Wang, J
    Krause, R
    Block, K
    Musameh, M
    Mulchandani, A
    Schöning, MJ
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3): : 255 - 260