An improved spinning lens test to determine the stiffness of the human lens

被引:29
|
作者
Burd, H. J. [1 ]
Wilde, G. S. [1 ]
Judge, S. J. [2 ]
机构
[1] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[2] Univ Oxford, Dept Physiol Anat & Genet, Oxford OX1 3QX, England
基金
英国惠康基金;
关键词
lens; stiffness; presbyopia; finite element; HUMAN CRYSTALLINE LENS; ACCOMMODATION; AGE; EYE; GRADIENT; NUCLEUS; INDEX; VIVO;
D O I
10.1016/j.exer.2010.10.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
It is widely accepted that age-related changes in lens stiffness are significant for the development of presbyopia. However, precise details on the relative importance of age-related changes in the stiffness of the lens, in comparison with other potential mechanisms for the development of presbyopia, have not yet been established. One contributing factor to this uncertainty is the paucity and variability of experimental data on lens stiffness. The available published data generally indicate that stiffness varies spatially within the lens and that stiffness parameters tend to increase with age. However, considerable differences exist between these published data sets, both qualitatively and quantitatively. The current paper describes new and improved methods, based on the spinning lens approach pioneered by Fisher, R.F. (1971) 'The elastic constants of the human lens', Journal of Physiology, 212, 147-180, to make measurements on the stiffness of the human lens. These new procedures have been developed in an attempt to eliminate, or at least substantially reduce, various systematic errors in Fisher's original experiment. An improved test rig has been constructed and a new modelling procedure for determining lens stiffness parameters from observations made during the test has been devised. The experiment involves mounting a human lens on a vertical rotor so that the lens spins on its optical axis (typically at 1000 rpm). An automatic imaging system is used to capture the outline of the lens, while it is rotating, at pre-determined angular orientations. These images are used to quantify the deformations developed in the lens as a consequence of the centripetal forces induced by the rotation. Lens stiffness is inferred using axisymmetric finite element inverse analysis in which a nearly-incompressible neo-Hookean constitutive model is used to represent the mechanics of the lens. A numerical optimisation procedure is used to determine the stiffness parameters that provide a best fit between the finite element model and the experimental data. Sample results are presented for a human lens of age 33 years. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 39
页数:12
相关论文
共 50 条
  • [1] Shear modulus data for the human lens determined from a spinning lens test
    Wilde, G. S.
    Burd, H. J.
    Judge, S. J.
    EXPERIMENTAL EYE RESEARCH, 2012, 97 (01) : 36 - 48
  • [2] The mechanical response of the porcine lens to a spinning test
    Reilly, Matthew A.
    Martius, Philipp
    Kumar, Saurav
    Burd, Harvey J.
    Stachs, Oliver
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (02): : 127 - 135
  • [3] SPINNING PIPE GAS LENS
    NOTCUTT, M
    MICHAELIS, MM
    CUNNINGHAM, PF
    WALTHAM, JA
    OPTICS AND LASER TECHNOLOGY, 1988, 20 (05): : 243 - 250
  • [4] ACCOMMODATION USED TO DETERMINE ULTRASOUND VELOCITY IN THE HUMAN LENS
    VANDERHEIJDE, GL
    WEBER, J
    OPTOMETRY AND VISION SCIENCE, 1989, 66 (12) : 830 - 833
  • [5] Pancharatnam lens acts as improved diffractive lens
    不详
    LASER FOCUS WORLD, 2015, 51 (11): : 9 - 9
  • [6] Stiffness gradient in the crystalline lens
    Henk A. Weeber
    Gabriele Eckert
    Wolfgang Pechhold
    Rob G. L. van der Heijde
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 1357 - 1366
  • [7] Stiffness gradient in the crystalline lens
    Weeber, Henk A.
    Eckert, Gabriele
    Pechhold, Wolfgang
    van der Heijde, Rob G. L.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (09) : 1357 - 1366
  • [8] Mouse lens stiffness measurements
    Baradia, Hussein
    Nikand, Negin
    Glasser, Adrian
    EXPERIMENTAL EYE RESEARCH, 2010, 91 (02) : 300 - 307
  • [9] Changes in lens stiffness due to capsular opacification in accommodative lens refilling
    Nibourg, Lisanne M.
    Sharma, Prashant K.
    van Kooten, Theo G.
    Koopmans, Steven A.
    EXPERIMENTAL EYE RESEARCH, 2015, 134 : 148 - 154
  • [10] THE SYMPOSIUM LENS IMPROVED
    BRIXNER, B
    APPLIED OPTICS, 1963, 2 (12): : 1331 - 1332