Accuracy of anemia screening by point-of-care hemoglobin testing in patients seeking abortion

被引:0
|
作者
Shapiro, Katherine E. [1 ]
Buhimschi, Irina A. [1 ]
Fleisher, Jonah [1 ]
机构
[1] Univ Illinois, Coll Med, Dept Obstet & Gynecol, Chicago, IL 60612 USA
关键词
Anemia; Hemoglobin; HemoCue; Point-of-care; Abortion; BLAND-ALTMAN ANALYSIS; HEMOCUE;
D O I
10.1016/j.contraception.2021.09.003
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Accurate and timely diagnosis of anemia in pregnancy is necessary for safe management of abortion care. Screening for anemia in abortion care is often accomplished using commercially-available point-of-care tests from capillary blood, but the validity of this test has not been investigated in the context of abortion care. We sought to determine the accuracy of a capillary hemoglobin (Hb) among pregnant patients seeking induced abortion. Study Design: We conducted a retrospective study of patients seeking abortion care at the University of Illinois at Chicago. We identified 108 subjects with paired capillary Hb and venous complete blood count (CBC) hemoglobin measurements within 7 days of each other and within 14 days before abortion. Agreement analysis was performed using Passing-Bablok regression and Bland-Altman plots. Results: More patients were deemed anemic by capillary than by venous Hb measurement (32% vs 19%, p = 0.030). Capillary Hb correlated with venous Hb (r = 0.85, p < 0.001). The average bias for capillary Hb was-1.1 +/- 1.0 g/dL. Step-wise, multivariable linear regression identified venous Hb as the only determinant of capillary Hb, and failed to identify any other predictors of bias. The agreement analysis between capillary and venous Hb by Passing-Bablok regression demonstrated systematic and proportional differences. Conclusion: Results from capillary Hb may be biased toward diagnosing anemia and should be interpreted with caution. Implications: Misdiagnosing anemia in abortion care can have several consequences and may prevent timely medical abortion or cause delayed procedural abortion. Clinical correlation, and possibly confirmation by venous complete blood count measurement, should be considered before clinical decision-making based solely upon the capillary point-of-care assay. (c) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:51 / 54
页数:4
相关论文
共 50 条
  • [1] Point-of-care hemoglobin testing for postmortem diagnosis of anemia
    Joo-Young Na
    Ji Hye Park
    Byung Ha Choi
    Hyung-Seok Kim
    Jong-Tae Park
    [J]. Forensic Science, Medicine and Pathology, 2018, 14 : 57 - 61
  • [2] Point-of-care hemoglobin testing for postmortem diagnosis of anemia
    Na, Joo-Young
    Park, Ji Hye
    Choi, Byung Ha
    Kim, Hyung-Seok
    Park, Jong-Tae
    [J]. FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2018, 14 (01) : 57 - 61
  • [3] Accuracy of Point-of-Care Testing for Anemia in the Emergency Department
    Osborn, Zachary T.
    Villalba, Nuria
    Derickson, Pamela R.
    Sewatsky, Thomas P.
    Wager, Abigail P.
    Freeman, Kalev
    [J]. RESPIRATORY CARE, 2019, 64 (11) : 1343 - 1350
  • [4] Point-of-care microchip electrophoresis for integrated anemia and hemoglobin variant testing
    An, Ran
    Man, Yuncheng
    Iram, Shamreen
    Kucukal, Erdem
    Hasan, Muhammad Noman
    Huang, Yuning
    Goreke, Utku
    Bode, Allison
    Hill, Ailis
    Cheng, Kevin
    Sekyonda, Zoe
    Ahuja, Sanjay P.
    Little, Jane A.
    Hinczewskib, Michael
    Gurkan, Umut A.
    [J]. LAB ON A CHIP, 2021, 21 (20) : 3863 - 3875
  • [5] Accuracy of point-of-care testing (POCT) for determining hemoglobin (HB) concentrations
    Gehring, H
    Hornberger, C
    Roth-Isigkeit, A
    Gerlach, K
    Dibbelt, L
    [J]. ANESTHESIOLOGY, 1999, 91 (3A) : U261 - U261
  • [6] Accuracy of noninvasive hemoglobin and invasive point-of-care hemoglobin testing compared with a laboratory analyzer
    Shah, N.
    Osea, E. A.
    Martinez, G. J.
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 (01) : 56 - 61
  • [7] VALIDATION OF POINT-OF-CARE HEMOGLOBIN TESTING IN ANEMIC ADULT PATIENTS
    Chan, Alan
    Lett, Ryan
    [J]. ANESTHESIA AND ANALGESIA, 2019, 128 : 625 - 627
  • [8] Accuracy and precision of hemoglobin point-of-care testing during major pediatric surgery
    Spielmann, N.
    Mauch, J.
    Madjdpour, C.
    Schmugge, M.
    Weiss, M.
    Haas, T.
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 (01) : 86 - 90
  • [9] Hemoglobin Point-of-Care Testing: The HemoCue System
    Sanchis-Gomar, Fabian
    Cortell-Ballester, Jose
    Pareja-Galeano, Helios
    Banfi, Giuseppe
    Lippi, Giuseppe
    [J]. JALA, 2013, 18 (03): : 198 - 205
  • [10] Point-of-Care Testing Effectiveness on Blood Donor Hemoglobin Testing
    Grech, Kayleigh
    Zammit, Vanessa
    [J]. LABORATORY MEDICINE, 2021, 52 (04) : 364 - 368