Identification of patients with embolic stroke of undetermined source and low risk of new incident atrial fibrillation: The AF-ESUS score

被引:38
|
作者
Ntaios, George [1 ]
Perlepe, Kalliopi [1 ]
Lambrou, Dimitris [1 ]
Sirimarco, Gaia [2 ,3 ]
Strambo, Davide [2 ,3 ]
Eskandari, Ashraf [2 ,3 ]
Karagkiozi, Efstathia [1 ]
Vemmou, Anastasia [4 ]
Korompoki, Eleni [4 ,5 ]
Manios, Efstathios [4 ]
Makaritsis, Konstantinos [1 ]
Vemmos, Konstantinos [4 ]
Michel, Patrik [2 ,3 ]
机构
[1] Univ Thessaly, Fac Med, Sch Hlth Sci, Dept Internal Med, Larisa, Greece
[2] Ctr Hosp Univ Vaudoi, Stroke Ctr Neurol Serv, Dept Clin Neurosci, Lausanne, Switzerland
[3] Univ Lausanne, Lausanne, Switzerland
[4] Natl & Kapodistrian Univ Athens, Dept Clin Therapeut, Athens, Greece
[5] Imperial Coll, Dept Stroke Med, Div Brain Sci, London, England
关键词
Embolic stroke of undetermined source; atrial fibrillation; prediction; prolonged cardiac monitoring; ISCHEMIC-STROKE; CRYPTOGENIC STROKE; ATHEROSCLEROSIS RISK; NATRIURETIC PEPTIDES; PREMATURE BEATS; CAROTID PLAQUES; DESIGN; ABNORMALITY; REGISTRY; ELECTROCARDIOGRAM;
D O I
10.1177/1747493020925281
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and aims Only a minority of patients with Embolic Stroke of Undetermined Source (ESUS) receive prolonged cardiac monitoring despite current recommendations. The identification of ESUS patients who have low probability of new diagnosis of atrial fibrillation (AF) could potentially support a strategy of more individualized allocation of available resources and hence, increase their diagnostic yield. We aimed to develop a tool that can identify ESUS patients who have low probability of new incident AF. Methods We performed multivariate stepwise regression in a pooled dataset of consecutive ESUS patients from three prospective stroke registries to identify predictors of new incident AF. The coefficient of each independent covariate of the fitted multivariable model was used to generate an integer-based point scoring system. Results Among 839 patients (43.1% women, median age 67.0 years) followed-up for a median of 24.3 months (2999 patient-years), 125 (14.9%) had new incident AF. The proposed score assigns 3 points for age >= 60 years; 2 points for hypertension; -1 point for left ventricular hypertrophy reported at echocardiography; 2 points for left atrial diameter >40 mm; -3 points for left ventricular ejection fraction <35%; 1 point for the presence of any supraventricular extrasystole recorded during all available 12-lead standard electrocardiograms performed during hospitalization for the ESUS; -2 points for subcortical infarct; -3 points for the presence of non-stenotic carotid plaques. The rate of new incident AF during follow-up was 1.97% among the 42.3% of the cohort who had a score of <= 0, compared to 26.9% in patients with > 0 (relative risk: 13.7, 95%CI: 5.9--31.5). The area under the curve of the score was 84.8% (95%CI: 79.9--86.9%). The sensitivity and negative predictive value of a score of <= 0 for new incident AF during follow-up were 94.9% (95%CI: 89.3--98.1%) and 98.0% (95%CI: 95.8--99.3%), respectively. Conclusions The proposed AF-ESUS score has high sensitivity and high negative predictive value to identify ESUS patients who have low probability of new incident AF. Patients with a score of 1 or more may be better candidates for prolonged automated cardiac monitoring.
引用
收藏
页码:29 / 38
页数:10
相关论文
共 50 条
  • [1] Validation of the AF-ESUS score to identify patients with embolic stroke of undetermined source and low risk of device-detected atrial fibrillation
    Kitsiou, Alkisti
    Sagris, Dimitrios
    Schaebitz, Wolf-Rudiger
    Ntaios, George
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2021, 89 : 135 - 136
  • [2] Supraventricular Extrasystoles on Standard 12-lead Electrocardiogram Predict New Incident Atrial Fibrillation after Embolic Stroke of Undetermined Source: The AF-ESUS Study
    Ntaios, George
    Perlepe, Kalliopi
    Lambrou, Dimitrios
    Sirimarco, Gaia
    Strambo, Davide
    Eskandari, Ashraf
    Karagkiozi, Efstathia
    Vemmou, Anastasia
    Koroboki, Eleni
    Manios, Efstathios
    Makaritsis, Konstantinos
    Michel, Patrik
    Vemmos, Konstantinos
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2020, 29 (04):
  • [3] Validation of Empoli Embolic Stroke of Undetermined Source Atrial Fibrillation (E2AF) Score for Detecting Atrial Fibrillation in Patients With Embolic Stroke of Undetermined Source
    Masotti, Luca
    Grifoni, Elisa
    Baglini, Alessia
    Sivieri, Irene
    Mannini, Marianna
    Iandoli, Gina
    Madonia, Elisa Maria
    Cosentino, Eleonora
    Micheletti, Irene
    Signorini, Ira
    Cioni, Elisa
    Sansone, Teresa
    Pelagalli, Giulia
    Baldini, Mariella
    Giannoni, Sara
    Bertini, Elisabetta
    Di Donato, Ilaria
    NEUROLOGIST, 2023, 28 (06) : 426 - 428
  • [4] The pads score - predicting incident atrial fibrillation in embolic stroke of undetermined source
    Chattopadhyay, Rahul
    Warburton, Elizabeth
    Tsampasian, Vasiliki
    Potter, John
    Mukherjee, Trisha
    Bhalraam, U.
    Vassiliou, Vassilios
    Khadjooi, Kayvan
    Ring, Liam
    Pugh, Peter
    Chousou, Anna
    Perperoglou, Aris
    HEART, 2023, 109 : A101 - A102
  • [5] Predicting incident atrial fibrillation in patients with embolic stroke of undetermined source
    Chousou, P. A.
    Chattopadhyay, R.
    Ring, L.
    Khadjooi, K.
    Warburton, E.
    Mukherjee, T.
    Bhalraam, U.
    Tsampasian, V.
    Potter, J.
    Perperoglou, A.
    Pugh, P.
    Vassiliou, V.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [6] Insertable cardiac monitors for detection of atrial fibrillation in patients with embolic stroke of undetermined source (ESUS) selected by risk factors
    Goetz, N.
    Poli, S.
    Haertig, F.
    Bauer, A.
    Duckheim, M.
    Eick, C.
    Schreieck, J.
    Gawaz, M.
    Ziemann, U.
    Meyer-Zurn, C. S.
    EUROPEAN HEART JOURNAL, 2015, 36 : 988 - 988
  • [7] Detecting Atrial Fibrillation in Patients With an Embolic Stroke of Undetermined Source (from the DAF-ESUS registry)
    Rubio Campal, Jose Manuel
    Garcia Torres, M. Araceli
    Sanchez Borque, Pepa
    Navas Vinagre, Inmaculada
    Zamarbide Capdepon, Ivana
    Miracle Blanco, Angel
    Bravo Calero, Loreto
    Saez Pinel, Rafael
    Tunon Fernandez, Jose
    Serratosa Fernandez, Jose Maria
    AMERICAN JOURNAL OF CARDIOLOGY, 2020, 125 (03): : 409 - 414
  • [8] Left atrial diameter thresholds and new incident atrial fibrillation in embolic stroke of undetermined source
    Perlepe, Kalliopi
    Sirimarco, Gaia
    Strambo, Davide
    Eskandari, Ashraf
    Karagkiozi, Efstathia
    Vemmou, Anastasia
    Koroboki, Eleni
    Manios, Efstathios
    Makaritsis, Konstantinos
    Vemmos, Konstantinos
    Michel, Patrik
    Ntaios, George
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2020, 75 : 30 - 34
  • [9] Left Atrial Volume Index is Associated With Atrial Fibrillation and Recurrent Stroke in Embolic Stroke of Undetermined Source (ESUS)
    Ho, Jamie S.
    Sia, Ching-Hui
    Boi, Yushan
    Foo, Anthia S.
    Dalakoti, Mayank
    Chan, Mark Y.
    Ngiam, Nicholas J.
    Chan, Bernard P.
    Teoh, Hock Luen
    Sharma, Vijay K.
    Kojodjojo, Pipin
    Seow, Swee-Chong
    Yeo, Leonard L.
    Tan, Benjamin Y.
    STROKE, 2020, 51
  • [10] The role of atrial fibrillation in patients with an embolic stroke of unknown source (ESUS)
    Wachter, Rolf
    Freedman, Ben
    THROMBOSIS AND HAEMOSTASIS, 2017, 117 (10) : 1833 - 1835