Delayed gastric emptying in ventilated critically ill patients:: Measurement by 13C-octanoic acid breath test

被引:93
|
作者
Ritz, MA [1 ]
Fraser, R
Edwards, N
Di Matteo, AC
Chapman, M
Butler, R
Cmielewski, P
Tournadre, JP
Davidson, G
Dent, J
机构
[1] Royal Adelaide Hosp, Dept Gastrointestinal Med, Adelaide, SA 5000, Australia
[2] Royal Adelaide Hosp, Dept Med, Adelaide, SA 5000, Australia
[3] Royal Adelaide Hosp, Dept Intens Care, Adelaide, SA 5000, Australia
[4] Womens & Childrens Hosp, Gastroenterol Unit, Adelaide, SA, Australia
关键词
motility; stomach; gastric emptying; gastric stasis; enteral feeding; intensive care unit; critically ill; mechanical ventilation; breath test; technique;
D O I
10.1097/00003246-200109000-00015
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To measure gastric emptying in ventilated critically ill patents with a new noninvasive breath test. Design: Single-center, open study. Setting: Combined medical and surgical intensive care unit of a university hospital. Subjects: Thirty unselected mechanically ventilated critically ill patients receiving gastric feeding and 22 healthy volunteers. Interventions: None. Patients: After 4 hrs without feeding, intragastric infusion of 100 mL of a liquid meal (Ensure) labeled with 100 muL C-13-octanoic acid. End-expiratory breath samples were collected into evacuated tubes from the respirator circuit every 5 mins for the first hour, then every 15 mins for 3 hrs. End-expiratory breath samples were also collected from volunteers studied supine after an overnight fast following an identical infusion via a nasogastric tube. Breath (CO2)-C-13 was measured with an isotope ratio mass spectrometer. Measurements and Main Results: Performance of the breath test posed no difficulty or interference with patient care. The CO2 level was >1% in 1297/1300 breath samples, indicating satisfactory end-expiratory timing. Data are median and interquartile range. Gastric emptying was slower in patients compared with volunteers: gastric emptying coefficient 2.93 (2.17-3.39) vs. 3.58 (3.18-3.79), p < .001 and gastric half emptying time, derived from the area under the (CO2)-C-13 curve, 155 min (130-220) vs. 133 min (120-145), p < .008. Fourteen of the 30 patients had a gastric emptying coefficient < 95% of all volunteers and 11 had a gastric half emptying time longer than 95% of all volunteers. The Acute Physiology and Chronic Health Evaluation (APACHE II) score (median 22, range 13-43) either at admission or on the day of the study did not correlate with gastric emptying coefficient. Conclusion: Gastric emptying of a calorie-dense liquid meal is slow in 40% to 45% of unselected mechanically ventilated patients in a combined medical and surgical intensive care unit. The C-13-octanoic acid breath test is a novel and useful bedside technique to measure gastric emptying in these patients.
引用
收藏
页码:1744 / 1749
页数:6
相关论文
共 50 条
  • [1] 13C-octanoic acid breath test for gastric emptying measurement
    Delbende, B
    Perri, F
    Couturier, O
    Leodolter, A
    Mauger, P
    Bridgi, B
    Bizais, Y
    des Varannes, SB
    Andriulli, A
    Galmiche, JP
    [J]. EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2000, 12 (01) : 85 - 91
  • [2] The role of 13C-octanoic acid breath testing in the assessment of gastric emptying in critically ill patients
    Nguyen, Nam Q.
    Chapman, Marianne
    Bellon, Max
    Bryant, Laura
    Burgstad, Carly
    Bartholemeuz, Dylan F.
    Butler, Ross
    Davidson, Geoff
    Fraser, Robert
    Holloway, Richard
    [J]. GASTROENTEROLOGY, 2006, 130 (04) : A247 - A247
  • [3] Gastric emptying evaluation by 13C-octanoic acid breath test
    Mansi, C
    Melga, P
    Savarino, V
    [J]. DIABETES NUTRITION & METABOLISM, 2004, 17 (01) : 43 - 46
  • [4] Measurement of gastric emptying by 13C-octanoic acid breath test versus scintigraphy in diabetics
    Zahn, A
    Langhans, CD
    Hoffner, S
    Haberkorn, U
    Rating, D
    Haass, M
    Enck, P
    Stremmel, W
    Rühl, A
    [J]. ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2003, 41 (05): : 383 - 390
  • [5] 13C-octanoic acid breath test to study gastric emptying time
    Bruno, G.
    Lopetuso, L. R.
    Ianiro, G.
    Laterza, L.
    Gerardi, V.
    Petito, V.
    Poscia, A.
    Gasbarrini, A.
    Ojetti, V.
    Scaldaferri, F.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2013, 17 : 59 - 64
  • [6] Delayed gastric emptying determined using the 13C-octanoic acid breath test in patients with systemic sclerosis
    Marie, Isabelle
    Gourcerol, Guillaume
    Leroi, Anne-Marie
    Menard, Jean-Francois
    Levesque, Herve
    Ducrotte, Philippe
    [J]. ARTHRITIS AND RHEUMATISM, 2012, 64 (07): : 2346 - 2355
  • [7] 13C-octanoic acid breath test for gastric emptying rate of solids
    Maes, BD
    Geypens, BJ
    Ghoos, YF
    Hiele, MI
    Rutgeerts, RJ
    [J]. GASTROENTEROLOGY, 1998, 114 (04) : 856 - 857
  • [8] Noninvasive 13C-octanoic acid breath test shows delayed gastric emptying in patients with amyotrophic lateral sclerosis
    Toepfer, M
    Folwaczny, C
    Lochmüller, H
    Schroeder, M
    Riepl, RL
    Pongratz, D
    Müller-Felber, W
    [J]. DIGESTION, 1999, 60 (06) : 567 - 571
  • [9] Measuring Gastric Emptying: Comparison of 13C-Octanoic Acid Breath Test and Scintigraphy
    Jari Punkkinen
    Ilmari Konkka
    Olli Punkkinen
    Tapani Korppi-Tommola
    Martti Färkkilä
    Jari Koskenpato
    [J]. Digestive Diseases and Sciences, 2006, 51 : 262 - 267
  • [10] Comparison of 13c-octanoic acid breath test and scintigraphy for measuring gastric emptying
    Punkkinen, JM
    Koskenpato, J
    Farkkila, M
    Kairamo, K
    Konkka, I
    [J]. GASTROENTEROLOGY, 2003, 124 (04) : A674 - A674