Central Corneal Thickness and Corneal Curvature in Pseudoexfoliation Syndrome With and Without Glaucoma

被引:23
|
作者
Ozcura, Fatih [1 ]
Aydin, Sayime [1 ]
Dayanir, Volkan [2 ]
机构
[1] Dumlupinar Univ, Sch Med, Dept Ophthalmol, TR-43270 Kutahya, Turkey
[2] Adnan Menderes Univ, Sch Med, Dept Ophthalmol, Aydin, Turkey
关键词
corneal curvature; central corneal thickness; glaucoma; keratometry; pseudoexfoliation; OPEN-ANGLE GLAUCOMA; NORMAL-TENSION GLAUCOMA; OCULAR HYPERTENSION; INTRAOCULAR-PRESSURE; AXIAL LENGTH; APPLANATION TONOMETRY; EXFOLIATION SYNDROME; REYKJAVIK EYE; GOLDMANN; ENDOTHELIUM;
D O I
10.1097/IJG.0b013e3181f7afb8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the central corneal thickness (CCT) and corneal curvature (CC) in pseudoexfoliative (PE) eyes with and without glaucoma. Methods: Charts of 551 consecutive patients undergoing preoperative examinations for cataract surgery between April 2006 and May 2009 in our clinic were reviewed retrospectively. Fourty-eight PE patients (48 eyes; 19 with glaucoma, 29 without glaucoma) and 48 age-matched and sex-matched control patients were enrolled in the study. The CCT, CC, intraocular pressure, and axial length were measured by ultrasonic pachymeter, autorefractokeratometer, Goldmann applanation tonometry, and ultrasound biometry, respectively. The independent samples t test and paired samples t test was used for the comparisons of the groups. Results: Mean CCT was significantly thinner in all PE and nonglaucomatous PE (Pseudoexfoliation syndrome "PES") eyes than in control eyes (P=0.004 and P=0.005, respectively). There was no difference in CCT between PE glaucoma (PEG) and control eyes (P=0.089). There was no difference in mean keratometry (K) and axial length in the study and control groups. In 22 unilateral PE eyes, mean CCT and K readings were insignificant between the PE eyes and fellow non-PE eyes. Conclusions: CCT was significantly thinner in eyes with PES compared with control eyes; however, difference between the PEG and control eyes was insignificant. In addition, mean K readings were not different in study and control eyes. Thinner CCT in eyes with PES, both as it is an independent risk factor and as a result of artificially lower intraocular pressure readings, may be an illuminating cause for development and rapid progression of glaucoma in the patients with PES.
引用
收藏
页码:410 / 413
页数:4
相关论文
共 50 条
  • [1] Corneal curvature and central corneal thickness in eyes with pseudoexfoliation syndrome
    Hepsen, Ibrahim E.
    Yagci, Ramazan
    Keskin, Urgcan
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2007, 42 (05): : 677 - 680
  • [2] Central corneal thickness in subjects with glaucoma and in normal individuals (with or without pseudoexfoliation syndrome)
    Kitsos, Georgios
    Gartzios, Christos
    Asproudis, Ioannis
    Bagli, Eleni
    [J]. CLINICAL OPHTHALMOLOGY, 2009, 3 : 537 - 542
  • [3] Evaluation of the Endothelial Cell Density and the Central Corneal Thickness in Pseudoexfoliation Syndrome and Pseudoexfoliation Glaucoma
    Tomaszewski, Bohydar T.
    Zalewska, Renata
    Mariak, Zofia
    [J]. JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [4] Diurnal variation in central corneal thickness and intraocular pressure in eyes with pseudoexfoliation syndrome without glaucoma
    Keel, Stuart
    Malesic, Linda
    Chan, Siew-Pang
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (11) : 1072 - 1076
  • [5] Comparison of central corneal thickness, corneal curvature and axial length values in pseudoexfoliation cases with or without cataract
    Okumus, Seydi
    Tatar, M. Gurkan
    Gungor, Kivanc
    Bekir, Necdet
    [J]. EUROPEAN JOURNAL OF THERAPEUTICS, 2011, 17 (03): : 137 - 140
  • [6] Central corneal thickness in patients with and without glaucoma
    Shafranov, G
    Soltau, JB
    Harmon, H
    Shields, MB
    Zimmerman, TJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S515 - S515
  • [7] Corneal curvature and central corneal thickness in a population-based sample of eyes with pseudoexfoliation syndrome - Reykjavik Eye Study
    Arnarsson, Arsaell
    Damji, Karim E.
    Jonasson, Fridbert
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2008, 43 (04): : 484 - 485
  • [8] Central corneal thickness and corneal volume changes in eyes with and without pseudoexfoliation after uneventful phacoemulsification
    Yonca Asfuroglu
    Ozlem Evren Kemer
    [J]. International Ophthalmology, 2019, 39 : 275 - 280
  • [9] Central corneal thickness and corneal volume changes in eyes with and without pseudoexfoliation after uneventful phacoemulsification
    Asfuroglu, Yonca
    Kemer, Ozlem Evren
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (02) : 275 - 280
  • [10] Morphological study of corneal endothelium and corneal thickness in pseudoexfoliation syndrome
    Inoue, K
    Okugawa, K
    Oshika, T
    Amano, S
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2003, 47 (03) : 235 - 239