The CMS preshower silicon sensors: Technology development and production in India

被引:5
|
作者
Topkar, Anita [1 ]
Aggarwal, Bharti [1 ]
Praveenkumar, S. [1 ]
Kataria, S. K. [1 ]
Rao, Y. P. Prabhakar [2 ]
机构
[1] Bhabha Atom Res Ctr, Div Elect, MOD Lab, Bombay 400080, Maharashtra, India
[2] Bharat Alect Ltd, Bangalore 560013, Karnataka, India
关键词
LHC; CMS; silicon strip detectors; silicon sensors; detector technology; electrical characterization;
D O I
10.1016/j.nima.2007.11.027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A specific research and development program has been carried out in India by Bhabha Atomic Research Centre to develop the technology for 32-strip silicon sensors which will be used as Preshower sensors in the CMS experiment at the Large Hadron Collider (LHC), CERN. The technology development was targeted to produce sensors which would qualify for reliable operation in a high radiation environment of LHC. As an outcome of this R&D effort, silicon sensors with very good performance have been produced and the production of thousand sensors for the CMS Preshower has been completed. In this paper, we present a summary of the R&D carried out to develop the technology of the silicon sensors. We report on various aspects such as sensor design, process development and characterization. The results of various tests carried out for evaluating the performance of the sensors during technology development and production phase have been presented. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 50 条
  • [1] Silicon sensors for the CMS preshower detector
    Bloch, P
    Chang, YH
    Chen, AE
    Cheremukhin, A
    Egorov, N
    Go, A
    Golubkov, S
    Golutvin, I
    Hou, SR
    Konjkov, K
    Kozlov, Y
    Kyriakis, A
    Lin, WT
    Loukas, D
    Markou, A
    Mousa, J
    Peisert, A
    Sidorov, A
    Tsoi, E
    Zamiatin, N
    Zubarev, E
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (2-3): : 265 - 277
  • [2] Silicon sensors development for the CMS pixel system
    Arndt, K
    Bolla, G
    Bortoletto, D
    Giolo, K
    Horisberger, R
    Roy, A
    Rohe, T
    Son, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (1-2): : 106 - 111
  • [3] Development and large-scale production of ceramic PCBs for the preshower detector of the CMS experiment
    Adamyan, F
    Avanesyan, H
    Asatryan, M
    Chatrchyan, S
    Hagopian, V
    Harutunyan, B
    Haykazyan, M
    Hovsepyan, A
    Sirunyan, A
    Shinkareva, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 551 (2-3): : 285 - 289
  • [4] Process control strategy of the silicon sensors production for the CMS tracker
    Bergauer, T
    Fontaine, JC
    Helleboid, JM
    Krammer, M
    Macchiolo, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 494 (1-3): : 218 - 222
  • [5] Optimization of the silicon sensors for the CMS tracker
    Albergo, S
    Angarano, M
    Azzi, P
    Babucci, E
    Bacchetta, N
    Bader, A
    Bagliesi, G
    Basti, A
    Biggeri, U
    Biino, C
    Bilei, GM
    Bisello, D
    Boemi, D
    Bosi, F
    Borello, L
    Braibant, S
    Breuker, H
    Brunetti, MT
    Bruzzi, M
    Buffini, A
    Busoni, S
    Candelori, A
    Caner, A
    Castaldi, R
    Castro, A
    Catacchini, E
    Checcucci, B
    Ciampolini, P
    Civinini, C
    Costa, M
    Creanza, D
    D'Alessandro, R
    DeMaria, N
    de Palma, M
    Dell'Orso, R
    Dutta, S
    Favro, G
    Fiore, L
    Focardi, E
    French, M
    Freudenreich, K
    Frey, A
    Friedl, M
    Fürtjes, A
    Giassi, A
    Giorgi, M
    Giraldo, A
    Glessing, W
    Gu, WH
    Hall, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (02): : 300 - 307
  • [6] Measurement of the bulk leakage current of silicon sensors of the CMS Preshower after an integrated luminosity of 6.17 fb-1, at √s=7 TeV
    Barney, D.
    Guthoff, M.
    Honma, A.
    Li, S-W.
    Peisert, A.
    Tzeng, Y-M.
    Qin, G.
    [J]. JOURNAL OF INSTRUMENTATION, 2013, 8
  • [7] The mass production of silicon sensors for the Phase-2 CMS Outer Tracker
    Damanakis, Konstantinos
    [J]. JOURNAL OF INSTRUMENTATION, 2023, 18 (12):
  • [8] The silicon sensors for the High Granularity Calorimeter of CMS
    Paulitsch, Peter
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 978
  • [9] Tests of silicon sensors for the CMS pixel detector
    Dorokhov, A
    Amsel, C
    Bortoletto, D
    Chiochia, V
    Cremaldi, L
    Cucciarelli, S
    Konecki, M
    Prokofiev, K
    Regenfus, C
    Rohe, T
    Sanders, D
    Son, S
    Speer, T
    Swartz, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 530 (1-2): : 71 - 76
  • [10] Tests of the silicon strip sensors for the CMS tracker
    Bergauer, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 317 - 320