Techno-Economic Analysis of Photovoltaic-Hydrogen Fuel Cell/Pumped Hydro Storage System for Micro Grid Applications: Case Study in Cyprus

被引:0
|
作者
Al-Ghussain, Loiy [1 ]
Samu, Remember [2 ]
Taylan, Onur [3 ]
Fahrioglu, Murat [4 ]
机构
[1] German Jordanian Univ, Dept Mechatron Engn, NanoLab, Amman, Jordan
[2] Middle East Tech Univ, Sustainable Environm & Energy Syst, Northern Cyprus Campus,Via Mersin 10, Guzelyurt, Northern Cyprus, Turkey
[3] Middle East Tech Univ, Mech Engn, Northern Cyprus Campus,Via Mersin 10, Guzelyurt, Northern Cyprus, Turkey
[4] Middle East Tech Univ, Elect & Elect Engn, Northern Cyprus Campus,Via Mersin 10, Guzelyurt, Northern Cyprus, Turkey
关键词
Fuel Cell; Pumped Hydro Storage System; Photovoltaic Systems; Hybrid Systems; RENEWABLE ENERGY SYSTEM; FEASIBILITY ANALYSIS; PERFORMANCE ANALYSIS; HYBRID; CELL; OPTIMIZATION;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Renewable energy resources such as solar resources are suitable alternatives for the use of fossil fuels as they are abundant, can be harnessed in affordable ways and are considered environmentally friendly. However, renewable energy resources fluctuate with time which decreases the matching between the energy produced by the renewable energy system and the demand and also decreases the reliability of the power supply. There are several potential ways to increase the matching and reliability of renewable energy systems such as the hybridization of renewable energy resources and the integration of energy storage. A techno-economic analysis of different configurations of Photovoltaic, Hydrogen Fuel Cell (HFC) and Pumped Hydro Storage (PHS) is carried out where Middle East Technical University Northern Cyprus Campus (METU NCC) is the case study. The optimal configurations of the PV system with different energy storage system configurations for the university are found based on maximizing the renewable energy (RES) fraction with Levelized Cost of Electricity (LCOE) equals to the grid tariff. However, the objective of the optimization becomes the maximization of the RES fraction with the minimum LCOE if there is no a feasible configuration. The results show that the integration of HFC and PHS system with the PV system increases the RES fraction and the demand-supply fraction from 36.2% to 45.4% and from 23.9% to 35.1%, respectively. The proposed system consists of 2.57 MW PV, 1.16 MWh HFC and 4.14 MWh PHS where such a system has LCOE of 0.181 USD/kWh.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Techno-Economic Analysis of Photovoltaic-LiIon Battery for Micro Grid Application: Case Study in Northern Cyprus
    Acikyildiz, Serdar
    Taplamacioglu, Cengiz
    [J]. 2022 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ICEEE 2022), 2022, : 255 - 259
  • [2] Techno-economic analysis of photovoltaic-hydrogen refueling station case study: A transport company Tunis-Tunisia
    Barhoumi, El Manaa
    Okonkwo, Paul C.
    Farhani, Slah
    Ben Belgacem, Ikram
    Zghaibeh, Manaf
    Mansir, Ibrahim B.
    Bacha, Faouzi
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (58) : 24523 - 24532
  • [3] Techno-economic analysis of micro fuel cell cogeneration and storage in Germany
    Loebberding, Laurens
    Madlener, Reinhard
    [J]. APPLIED ENERGY, 2019, 235 : 1603 - 1613
  • [4] Flexibility definition and improvement of pumped hydro storage: A techno-economic analysis
    Wu, Zhi
    Feng, Yizhou
    Li, Xinyu
    Yuan, Bo
    [J]. JOURNAL OF ENERGY STORAGE, 2024, 93
  • [5] Sizing and techno-economic analysis of a grid connected photovoltaic system with hybrid storage
    Bensmaine, Faycal
    Abbes, Dhaker
    Labrunie, Antoine
    Robyns, Benoit
    [J]. 2016 51ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2016,
  • [6] A new techno-economic analysis of fuel cell in Photovoltaic pumping system
    Khiareddine, Abla
    Bouallegue, Ghaith
    Mimouni, Mohamed Faouzi
    [J]. 2019 19TH INTERNATIONAL CONFERENCE ON SCIENCES AND TECHNIQUES OF AUTOMATIC CONTROL AND COMPUTER ENGINEERING (STA), 2019, : 411 - 416
  • [7] Techno-economic analysis of a standalone solar PV with groundwater pumped-hydro-storage system
    Shirinda, K.
    Kusakana, K.
    Koko, S. P.
    [J]. PROCEEDINGS OF THE 2019 TWENTY SEVENTH INTERNATIONAL CONFERENCE ON THE DOMESTIC USE OF ENERGY (DUE), 2019, : 90 - 95
  • [8] Hydrogen underground storage for grid electricity storage: An optimization study on techno-economic analysis
    Chen, Yunzhi
    Hill, Daniel
    Billings, Blake
    Hedengren, John
    Powell, Kody
    [J]. Energy Conversion and Management, 2024, 322
  • [9] TECHNO-ECONOMIC ANALYSIS OF A GRID-CONNECTED RESIDENTIAL PHOTOVOLTAIC SYSTEM: A ROMANIAN CASE STUDY
    Cristea, Ciprian
    Cristea, Maria
    Birou, Iulian
    Pica, Constantin-Sorin
    Tirnovan, Radu-Adrian
    Serban, Florica Mioara
    Stoenoiu, Carmen-Elena
    [J]. ACTA TECHNICA NAPOCENSIS SERIES-APPLIED MATHEMATICS MECHANICS AND ENGINEERING, 2019, 62 (04): : 543 - 550
  • [10] Techno-economic assessment of integrating hydrogen energy storage technology with hybrid photovoltaic/pumped storage hydropower energy system
    Alili, Hadis
    Mahmoudimehr, Javad
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2023, 294