A novel approach to patient-specific quality assurance: Three-dimensional visualization and verification of intensity-modulated treatment plans using magnetic resonance imaging of polymer gel dosimeters

被引:0
|
作者
Witten, M
Xu, Y
Maryanski, M
Wuu, C
机构
[1] Long Isl Radiat Therapy, Manhasset, NY USA
[2] MGS Res Inc, Guildford, CT USA
[3] Columbia Univ, New York, NY USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:1499 / 1499
页数:1
相关论文
共 31 条
  • [1] Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters
    Ibbott, GS
    Maryanski, MJ
    Eastman, P
    Holcomb, SD
    Zhang, YS
    Avison, RG
    Sanders, M
    Gore, JC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (05): : 1097 - 1103
  • [2] A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions
    Karger, CP
    Jäkel, O
    Hartmann, GH
    Heeg, P
    MEDICAL PHYSICS, 1999, 26 (10) : 2125 - 2132
  • [3] Quality Assurance of Nasopharyngeal Carcinoma Intensity Modulated Radiotherapy Treatment Plans Using Three Dimensional Dosimetry Verification System
    Ma, C.
    Yin, Y.
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (09) : S321 - S321
  • [4] Three-dimensional measurement of dose distribution produced by an intensity modulated radiation therapy system using magnetic resonance of BANG polymer gel dosimeters
    Wong, PS
    Lin, CY
    Cardenas, RL
    Cheng, KK
    RADIOLOGY, 1998, 209P : 397 - 397
  • [5] MAGIC-type polymer gel for three-dimensional dosimetry:: Intensity-modulated radiation therapy verification
    Gustavsson, H
    Karlsson, A
    Bäck, SÅJ
    Olsson, LE
    Haraldsson, P
    Engström, P
    Nyström, H
    MEDICAL PHYSICS, 2003, 30 (06) : 1264 - 1271
  • [6] A unified deep-learning framework for enhanced patient-specific quality assurance of intensity-modulated radiation therapy plans
    Looe, Hui Khee
    Reinert, Philipp
    Carta, Julius
    Poppe, Bjoern
    MEDICAL PHYSICS, 2025, 52 (03) : 1878 - 1892
  • [7] Dose verification of a clinical intensity-modulated radiation therapy eye case by the magnetic resonance imaging of N-isopropylacrylamide gel dosimeters
    Chen, Yen-Li
    Hsieh, Bor-Tsung
    Chiang, Chih-Ming
    Shih, Cheng-Ting
    Cheng, Kai-Yuan
    Hsieh, Ling-Ling
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 188 - 191
  • [8] Analysis of measurement deviations for the patient-specific quality assurance using intensity-modulated spot-scanning particle beams
    Li, Yongqiang
    Hsi, Wen C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (07): : 2675 - 2693
  • [9] Quick, efficient and effective patient-specific intensity-modulated radiation therapy quality assurance using log file and electronic portal imaging device
    Kumar, Rajesh
    Amols, H. I.
    Lovelock, M.
    Sharma, S. D.
    Datta, D.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (02) : 297 - 303
  • [10] Development of a three-dimensional scintillation detector for pencil beam verification in proton therapy patient-specific quality assurance
    Frelin, Anne-Marie
    Daviau, Gautier
    Bui, My Hoang Hoa
    Fontbonne, Cathy
    Fontbonne, Jean-Marc
    Lebhertz, Dorothee
    Mainguy, Erwan
    Moignier, Cyril
    Thariat, Juliette
    Vela, Anthony