Determination of Acrylamide in PDA with Near Infrared Reflectance Spectroscopy

被引:2
|
作者
Zheng Huai-li [1 ]
Zhang Peng [1 ]
Zhu Guo-cheng [1 ]
Zhu Chuan-jun [2 ]
Wang Jing-jing [1 ]
Jiang Shao-jie [1 ]
Yu Bing-hong [1 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Three Gorges Reservoir Reg Ecoenvironm, Chongqing 400045, Peoples R China
[2] Tianjin Chem Res & Design Inst, Tianjin 300131, Peoples R China
关键词
PDA; Content of residual acrylamide; Near infrared reflectance spectroscopy; Wavelet analysis; Partial least squares (PLS); CHROMATOGRAPHY;
D O I
10.3964/j.issn.1000-0593(2011)11-2944-04
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In the present study, near infrared reflectance spectroscopy(NIRS) was used as a rapid and accurate method to determine the residual of acrylamide monomer in the product of diallyl dimethyl ammonium chloride and acrylamide. In this experiment 38 products were used which were self-prepared in the laboratory, then near infrared spectra of the product were scanned, seven bands were selected, the characteristic peaks of each band were used as the independent variables, and the absorption peak was used as the dependent variable, using partial least squares (PLS) method to establish the mathematical conversion near infrared reflectance spectroscopy (NIRS) calibration model. In the analysis of the spectrum, using wavelet analysis as the method of reducing the noise of spectrum, and with comparison of the simulated value and measured value, the measured value was determined by using UV spectrum, the external validation determination coefficient was found to be 0. 99, and the distribution trend forecast was good. Statistics showed that there was no significant difference between simulated value and measured value. The results show that using the calibration model established by the data of near infrared spectroscopy to predict the residual AM monomer in PDA is of high feasibility.
引用
收藏
页码:2944 / 2947
页数:4
相关论文
共 13 条
  • [1] [Anonymous], DETERMINATION RESIEU, P3
  • [2] Near infrared applications in the quality control of seed cotton
    Gaitan-Jurado, Antonio J.
    Garcia-Molina, Maria
    Pena-Rodriguez, Francisco
    Ortiz-Somovilla, Victor
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2008, 16 (04) : 421 - 429
  • [3] Jiang Y, 2008, PROG CHEM, V20, P2021
  • [4] An improved LC-MS/MS method for the quantitation of acrylamide in processed foods
    Kim, Cheong Tae
    Hwang, Eun-Sun
    Lee, Hyong Joo
    [J]. FOOD CHEMISTRY, 2007, 101 (01) : 401 - 409
  • [5] [吕乐 Lu Le], 2010, [环境工程学报, Chinese Journal of Environmental Engineering], V4, P521
  • [6] Retention studies of acrylamide for the design of a robust liquid chromatography-tandem mass spectrometry method for food analysis
    Rosen, Johan
    Nyman, Arne
    Hellenas, Karl-Erik
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (01) : 19 - 24
  • [7] Pharmaceutical Applications of Separation of Absorption and Scattering in Near-Infrared Spectroscopy (NIRS)
    Shi, Zhenqi
    Anderson, Carl A.
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 99 (12) : 4766 - 4783
  • [8] Yang Wei-hua, 2009, Huanjing Kexue, V30, P2277
  • [9] Zhang Zhiyong, 2010, Chinese Journal of Lasers, V37, P696, DOI 10.3788/CJL20103703.0696
  • [10] [赵松梅 Zhao Songmei], 2005, [北京化工大学学报. 自然科学版, Journal of Beijing University of Chemical Technology. Natural Science Edition], V32, P29