ULTRASOUND SPECKLE TRACKING STRAIN ESTIMATION OF IN VIVO CAROTID ARTERY PLAQUE WITH IN VITRO SONOMICROMETRY VALIDATION

被引:32
|
作者
Widman, Erik [1 ]
Caidahl, Kenneth [2 ]
Heyde, Brecht [3 ]
D'hooge, Jan [3 ]
Larsson, Matilda [1 ,3 ]
机构
[1] KTH Royal Inst Technol, Sch Technol & Hlth, Dept Med Engn, S-14152 Huddinge, Sweden
[2] Karolinska Inst, Dept Mol Med & Surg, Stockholm, Sweden
[3] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2015年 / 41卷 / 01期
基金
瑞典研究理事会;
关键词
Carotid artery; In vitro; In vivo; Phantom; Plaque characterization; Speckle tracking; Strain; Ultrasound; Validation; AXIAL STRAIN; RISK; ENDARTERECTOMY; ECHOLUCENCY; STROKE; ELASTOGRAPHY; STENOSIS; FEATURES; CLASSIFICATION; COMPONENTS;
D O I
10.1016/j.ultrasmedbio.2014.06.013
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Our objective was to validate a previously developed speckle tracking (ST) algorithm to assess strain in common carotid artery plaques. Radial and longitudinal strain was measured in common carotid artery gel phantoms with a plaque-mimicking inclusion using an in-house ST algorithm and sonomicrometry. Moreover, plaque strain by ST for seven patients (77 +/- 6 y) with carotid atherosclerosis was compared with a quantitative visual assessment by two experienced physicians. In vitro, good correlation existed between ST and sonomicrometry peak strains, both radially (r = 0.96, p < 0.001) and longitudinally (r = 0.75, p < 0.01). In vivo, greater pulse pressure-adjusted radial and longitudinal strains were found in echolucent plaques than in echogenic plaques. This illustrates the feasibility of ultrasound ST strain estimation in plaques and the possibility of characterizing plaques using ST strain in vivo. (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:77 / 88
页数:12
相关论文
共 50 条
  • [1] Speckle Tracking Strain Estimation of a Carotid Artery Plaque Phantom - Validation via Sonomicrometry
    Widman, Erik
    Caidahl, Kenneth
    Heyde, Brecht
    D'hooge, Jan
    Larsson, Matilda
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1757 - 1760
  • [2] Ultrasound speckle tracking for radial, longitudinal and circumferential strain estimation of the carotid artery - An in vitro validation via sonomicrometry using clinical and high-frequency ultrasound
    Larsson, Matilda
    Heyde, Brecht
    Kremer, Florence
    Brodin, Lars-Ake
    D'hooge, Jan
    [J]. ULTRASONICS, 2015, 56 : 399 - 408
  • [3] In vivo Radial and Longitudinal Carotid Artery Plaque Strain Estimation via Ultrasound- Based Speckle Tracking
    Widman, Erik
    Caidahl, Kenneth
    Larsson, Matilda
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 523 - 526
  • [4] Strain assessment in the carotid artery wall using ultrasound speckle tracking: validation in a sheep model
    Larsson, Matilda
    Verbrugghe, Peter
    Smoljkic, Marija
    Verhoeven, Jelle
    Heyde, Brecht
    Famaey, Nele
    Herijgers, Paul
    D'hooge, Jan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1107 - 1123
  • [5] Ultrasound Speckle Tracking System Using Radiofrequency Data for Simultaneous Computation of Strain and Strain Rate: Validation Against Sonomicrometry
    Ashraf, Muhammad
    Carlson, Max
    Newey, Colleen
    Ashraf, Shiza
    Li, Karen
    Yang, Sarah K.
    Hamilton, Jamie
    Sahn, David J.
    [J]. CIRCULATION, 2010, 122 (21)
  • [6] Validation of Speckle Tracking Based Strain Analysis for Study of Dynamic Function of the Heart by Sonomicrometry
    Ashraf, Muhammad
    Mahajan, Aman
    Shivkumar, Kalyanam
    Niemann, Petra S.
    Gu, Tara
    Han, Xiao-Yue
    Lee, Thomas L.
    Imanbayev, Galym
    Sahn, David J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A260 - A260
  • [7] Assessment of longitudinal strain in the Carotid artery wall using ultrasound-based Speckle tracking - validation in a sheep model
    Larsson, Matilda
    Verbrugghe, Peter
    Smoljkic, Marija
    Heyde, Brecht
    Famaey, Nele
    Herijgers, Paul
    D'hooge, Jan
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 565 - 568
  • [8] Speckle Tracking Based Evaluation of Three-Dimensional Strain: Validation Against Sonomicrometry
    Ashraf, Muhammad
    Shentu, Weihui
    Zhou, Zhiwen
    Sahn, David J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A464 - A464
  • [9] Speckle Tracking Ultrasound Is Independent of Insonation Angle and Gain: An In Vitro Investigation of Agreement with Sonomicrometry
    Sivesgaard, Kim
    Christensen, Sara Dahl
    Nygaard, Hans
    Hasenkam, J. Michael
    Sloth, Erik
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (07) : 852 - 858
  • [10] Influence of ultrasound speckle tracking strategies for motion and strain estimation
    Curiale, Ariel H.
    Vegas-Sanchez-Ferrero, Gonzalo
    Aja-Fernandez, Santiago
    [J]. MEDICAL IMAGE ANALYSIS, 2016, 32 : 184 - 200