Fibrinogen determination according to Clauss: commutability assessment of International and commercial standards and quality control samples

被引:12
|
作者
van den Besselaar, Antonius M. H. P. [1 ,2 ,3 ]
van Rijn, Claudia J. J. [1 ,3 ]
Cobbaert, Christa M. [1 ,3 ]
Reijnierse, G. Louis A. [4 ]
Hollestelle, Martine J. [4 ,5 ]
Niessen, Rene W. L. M. [4 ,6 ]
Hudig, Francisca [4 ,7 ]
机构
[1] Leiden Univ, Med Ctr, Coagulat Reference Lab, POB 9600, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Thrombosis & Hemostasis, Leiden, Netherlands
[3] Leiden Univ, Med Ctr, Dept Clin Chem & Lab Med, Leiden, Netherlands
[4] Dutch Fdn Qual Assurance Med Labs SKML, Sect Coagulat, Nijmegen, Netherlands
[5] Sanquin Diagnost Serv, Dept Immunopathol & Blood Coagulat, Amsterdam, Netherlands
[6] Clin Lab Medlon, Hengelo, Netherlands
[7] Haga Teaching Hosp, Labwest, The Hague, Netherlands
关键词
Clauss assay; commutability; external quality assessment; fibrinogen; FRAMEWORK;
D O I
10.1515/cclm-2016-1088
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Many clinical laboratories use a clotting rate assay according to Clauss for the determination of fibrinogen in citrated plasma. The aim of the present study was to assess the commutability of the current International Standard for fibrinogen (coded 09/264), three commercial fibrinogen standards, and 10 freeze-dried plasma quality control samples from various sources. Methods: Clotting rate assays according to Clauss were performed on three automated instruments (Sysmex CA1500, STA-Rack Evolution and ACL-Top 700), using three commercial thrombin reagents (Siemens, Stago, and Instrumentation Laboratory). Relationships between the results obtained with the three instruments were determined with 25 fresh-frozen plasma samples obtained from patients. The deviations of the assay results obtained with the freeze-dried samples were compared with the deviations obtained with the freshfrozen samples, according to approved CLSI guideline C53A. Results: Freezing and thawing had no influence on the assay results. There were significant differences in the mean assay results (fibrinogen, g/L) for the fresh-frozen plasma samples between the three automated instruments: 2.51 (STA-Rack Evolution), 2.25 (ACL-Top 700) and 2.20 (Sysmex CA1500). Similar differences were observed for several freeze-dried plasma samples. Some freeze-dried plasma samples, including the International Standard, were out of the 95% confidence interval for the relationship between STA-Rack Evolution and Sysmex CA1500. Conclusions: Some freeze-dried plasmas including the international standard for fibrinogen are not commutable among automated instruments for fibrinogen clotting rate assays according to Clauss. Our results have consequences for all interested parties in the traceability chain (WHO, industry, external quality assessment schemes, clinical laboratories).
引用
收藏
页码:1761 / 1769
页数:9
相关论文
共 50 条
  • [1] Quality control according to the international standards
    [J]. Promyshlennoe Stroitel'stvo, (11):
  • [2] SOME CHARACTERISTICS OF NYCOTEST - FIBRINOGEN(TM), A NOVEL FIBRINOGEN DETERMINATION KIT ACCORDING TO THE METHOD OF CLAUSS
    FILIONMYKLEBUST, C
    MYDLAND, E
    MARIGARD, T
    JANSON, T
    [J]. THROMBOSIS AND HAEMOSTASIS, 1995, 73 (06) : 1244 - 1244
  • [3] A safety assessment framework of control systems according to international standards
    Suyama, Koichi
    Sebe, Noboru
    [J]. ASIAN JOURNAL OF CONTROL, 2020, 22 (05) : 1741 - 1754
  • [4] Commutability and interchangeability of commercial quality control materials with feline plasma for common biochemical analytes
    Baral, Randolph M.
    Dhand, Navneet K.
    Freeman, Kathleen P.
    [J]. VETERINARY CLINICAL PATHOLOGY, 2016, 45 (02) : 300 - 310
  • [5] Safety design of control systems according to international standards
    Suyama, Koichi
    Sebe, Noboru
    [J]. 2021 EUROPEAN CONTROL CONFERENCE (ECC), 2021, : 1310 - 1315
  • [6] Quality assessment of Coffea arabica commercial samples
    Viapiana, Agnieszka
    Maggi, Filippo
    Kaszuba, Mateusz
    Konieczynski, Pawel
    Wesolowski, Marek
    [J]. NATURAL PRODUCT RESEARCH, 2020, 34 (21) : 3154 - 3157
  • [7] QUALITY AND QUALITY-CONTROL, SHOWN BY COMMERCIAL SAMPLES
    BERGEL, C
    [J]. FLUSSIGES OBST, 1982, (11): : 638 - &
  • [8] LACK OF COMMUTABILITY BETWEEN QUALITY CONTROL MATERIALS AND PLASMA SAMPLES IN A TROPONIN I ASSAY
    Candas-Estebanez, B.
    Cano-Corres, R.
    Dot-Bach, D.
    Valero-Politi, J.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S713 - S713
  • [9] Lack of commutability between a quality control material and plasma samples in a troponin I measurement system
    Candas-Estebanez, Beatriz
    Cano-Corres, Ruth
    Dot-Bach, Dolors
    Valero-Politi, Jose
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (12) : 2237 - 2238
  • [10] A dependability analysis framework for control systems according to international standards
    Miura, Rinka
    Suyama, Koichi
    [J]. 2022 61ST ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS (SICE), 2022, : 1213 - 1219