Comparison of Ambulatory Tonometric and Oscillometric Blood Pressure Monitoring in Hypertensive Patients

被引:6
|
作者
Hornstrup, Bodil Gade [1 ,2 ]
Rosenbaek, Jeppe Bakkestrom
Bech, Jesper Norgaard
机构
[1] Reg Hosp West Jutland, Univ Clin Nephrol & Hypertens, Holstebro, Denmark
[2] Aarhus Univ, Holstebro, Denmark
来源
关键词
ambulatory blood pressure monitoring; oscillometric; tonometric; PROGNOSTIC VALUE; MANAGEMENT; MORTALITY; BURDEN;
D O I
10.2147/IBPC.S235228
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Aim: Correct measurement of blood pressure (BP) is important for optimal diagnosis and treatment of patients with hypertension. The aim of this study was to compare a wrist-worn device using tonometric measurements of BP to a conventional device using oscillometric measurements of 24 h BP, diagnosing of hypertension, and non-dipping. Methods: One-hundred patients in the Renal Outpatient Clinic had 24 h ambulatory BP monitoring performed with a tonometric device, BPro, and an oscillometric device, A&D, simultaneously. Results: Twenty-four-hour and daytime systolic BP was significantly lower using tonometric monitoring compared to oscillometric (7 and 6 mmHg, respectively, p< 0.001). In the population of patients diagnosed with hypertension, the tonometric device diagnosed 90% of patients with uncontrolled hypertension correctly (positive predictive value), whereas 49% of patients classified as normotensive were uncontrolled hypertensive (negative predictive value). The mean difference between relative nocturnal BP decrease between tonometric and oscillometric was 2+8% (p< 0.01), and 33% of patients classified as dippers were nondippers (negative predictive value). Conclusion: Using the BPro device for tonometric monitoring of BP and classification of hypertension and non-dipping in patients diagnosed with hypertension leads to misclassification of patients. Therefore, the BPro device is not suitable for clinical practice in hypertensive patients from a Renal Outpatient Clinic.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [1] Comparison of a tonometric with an oscillometric blood pressure monitoring device over 24 hours of ambulatory use
    Miranda Hurtado, Martin
    Reyes Vasquez, Javiera
    Rodriguez-Fernandez, Maria
    BLOOD PRESSURE MONITORING, 2021, 26 (02) : 149 - 155
  • [2] AUSCULTATORY AND OSCILLOMETRIC AMBULATORY BLOOD PRESSURE MONITORING: METHODS COMPARISON IN ADULT PATIENTS
    Zhemanyuk, Svitlana Pavlina
    Syvolap, Vitaliy Victorovich
    JOURNAL OF HYPERTENSION, 2023, 41 : E208 - E208
  • [3] Ambulatory blood pressure monitoring in the diagnosis of hypertensive patients
    Waeber, B
    Brunner, HR
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1996, 126 (33) : 1403 - 1406
  • [4] Comparison of blood pressure measurement consistency using tonometric and automated oscillometric instruments
    Yucha, CB
    Calderon, KS
    Tsai, PS
    Yang, MCK
    APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2002, 27 (04) : 306 - 306
  • [5] Ambulatory Tonometric Blood Pressure Measurements in Patients with Diabetes
    Theilade, Simone
    Joergensen, Christel
    Persson, Frederik
    Lajer, Maria
    Rossing, Peter
    DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (06) : 453 - 456
  • [6] Comparison of an auscultatory versus an oscillometric ambulatory blood pressure monitor in normotensive, hypertensive, and preeclamptic pregnancy
    Franx, A
    vanderPost, JAM
    vanMontfrans, GA
    Bruinse, HW
    HYPERTENSION IN PREGNANCY, 1997, 16 (02) : 187 - 202
  • [7] Comparison between ambulatory blood pressure monitoring and office blood pressure in the assessment of blood pressure control in resistant hypertensive patients
    Rodrigues, CS
    Bloch, KV
    Muxfeldt, ES
    Nogueira, AR
    Barros, OO
    JOURNAL OF HYPERTENSION, 2004, 22 : S137 - S137
  • [8] Comparison of noninvasive estimations of central blood pressure by tonometric radial pressure waveform calibrated with oscillometric brachial blood pressure
    Hirata, K.
    Sagawa, Y.
    Kojima, I.
    Yamazaki, M.
    Shinomiya, N.
    Miyawaki, Y.
    Momomura, S. -I.
    JOURNAL OF HYPERTENSION, 2008, 26 : S490 - S490
  • [9] The role of ambulatory blood pressure monitoring in elderly hypertensive patients
    Mancia, G
    Parati, G
    BLOOD PRESSURE, 2000, 9 : 12 - 16
  • [10] Abnormalities in ambulatory blood pressure monitoring in hypertensive patients with diabetes
    Gorostidi, Manuel
    de la Sierra, Alejandro
    Gonzalez-Albarran, Olga
    Segura, Julian
    de la Cruz, Juan J.
    Vinyoles, Ernest
    Llisterri, Jose L.
    Aranda, Pedro
    Ruilope, Luis M.
    Banegas, Jose R.
    HYPERTENSION RESEARCH, 2011, 34 (11) : 1185 - 1189