The New Freezing of Gait Questionnaire: Unsuitable as an Outcome in Clinical Trials?

被引:66
|
作者
Hulzinga, Femke [1 ]
Nieuwboer, Alice [1 ]
Dijkstra, Bauke W. [1 ]
Mancini, Martina [2 ]
Strouwen, Carolien [3 ]
Bloem, Bastiaan R. [4 ]
Ginis, Pieter [1 ]
机构
[1] Katholieke Univ Leuven, Neurorehabil Res Grp, Dept Rehabil Sci, Leuven, Belgium
[2] Oregon Hlth & Sci Univ, Dept Neurol, Portland, OR 97201 USA
[3] UHasselt, Rehabil Res Ctr, Fac Rehabil Sci, Hasselt, Belgium
[4] Radboud Univ Nijmegen, Med Ctr, Donders Inst Brain Cognit & Behav, Dept Neurol,Ctr Expertise Parkinson & Movement Di, Nijmegen, Netherlands
来源
基金
美国国家卫生研究院;
关键词
new freezing of gait questionnaire; freezing of gait; minimal detectable change; reliability; PARKINSONS-DISEASE; CONNECTIVITY; ISTRADEFYLLINE; ONSET;
D O I
10.1002/mdc3.12893
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Freezing of gait (FOG) is a common gait deficit in Parkinson's disease. The New Freezing of Gait Questionnaire (NFOG-Q) is a widely used and valid tool to quantify freezing of gait severity. However, its test-retest reliability and minimal detectable change remain unknown. Objective To determine the test-retest reliability and responsiveness of the NFOG-Q. Methods Two groups of freezers, involved in 2 previous rehabilitation trials, completed the NFOG-Q at 2 time points (T1 and T2), separated by a 6-week control period without active intervention. Sample 1 (N = 57) was measured in ON and sample 2 (N = 14) in OFF. We calculated various reliability statistics for the NFOG-Q scores between T1 and T2 as well as correlation coefficients with clinical descriptors to explain the variability between time points. Results In sample 1 the NFOG-Q showed modest reliability (intraclass correlation coefficient = 0.68 [0.52-0.80]) without differences between T1 and T2. However, a minimal detectable change of 9.95 (7.90-12.27) points emerged for the total score (range 28 points, relative minimal detectable change of 35.5%). Sample 2 showed largely similar results. We found no associations between cognitive-related or disease severity-related outcomes and variability in NFOG-Q scores. Conclusions We conclude that the NFOG-Q is insufficiently reliable or responsive to detect small effect sizes, as changes need to go beyond 35% to surpass measurement error. Therefore, we warrant caution in using the NFOG-Q as a primary outcome in clinical trials. These results emphasize the need for robust and objective freezing of gait outcome measures.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 50 条
  • [1] A feasibility study of objective outcome measures used in clinical trials of freezing of gait
    Gonzalo J. Revuelta
    Aaron Embry
    Jordan J. Elm
    Shonna Jenkins
    Philip Lee
    Steve Kautz
    Pilot and Feasibility Studies, 8
  • [2] A feasibility study of objective outcome measures used in clinical trials of freezing of gait
    Revuelta, Gonzalo J.
    Embry, Aaron
    Elm, Jordan J.
    Jenkins, Shonna
    Lee, Philip
    Kautz, Steve
    PILOT AND FEASIBILITY STUDIES, 2022, 8 (01)
  • [3] The validation of an Italian version of the Freezing of Gait Questionnaire
    Tambasco, Nicola
    Simoni, Simone
    Eusebi, Paolo
    Ripandelli, Francesco
    Brahimi, Elona
    Sacchini, Elisa
    Nigro, Pasquale
    Marsili, Erica
    Calabresi, Paolo
    NEUROLOGICAL SCIENCES, 2015, 36 (05) : 759 - 764
  • [4] Validity of the Brazilian version of the freezing of gait questionnaire
    Oliveira Baggio, Jussara A.
    Curtarelli, Monica B.
    Rodrigues, Guilherme R.
    Tumas, Vitor
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2012, 70 (08) : 599 - 603
  • [5] The validation of an Italian version of the Freezing of Gait Questionnaire
    Nicola Tambasco
    Simone Simoni
    Paolo Eusebi
    Francesco Ripandelli
    Elona Brahimi
    Elisa Sacchini
    Pasquale Nigro
    Erica Marsili
    Paolo Calabresi
    Neurological Sciences, 2015, 36 : 759 - 764
  • [6] Construction of freezing of gait questionnaire for patients with Parkinsonism
    Giladi, N
    Shabtai, H
    Simon, ES
    Biran, S
    Tal, J
    Korczyn, AD
    PARKINSONISM & RELATED DISORDERS, 2000, 6 (03) : 165 - 170
  • [7] The validation of a Japanese version of the New Freezing of Gait Questionnaire (NFOG-Q)
    Taniguchi, Seira
    Marumoto, Kohei
    Kajiyama, Yuta
    Revankar, Gajanan
    Inoue, Michiko
    Yamamoto, Hiroshi
    Kayano, Rika
    Mizuta, Eiji
    Takahashi, Ryuichi
    Shirahata, Emi
    Saeki, Chizu
    Ozono, Tatsuhiko
    Kimura, Yasuyoshi
    Ikenaka, Kensuke
    Mochizuki, Hideki
    NEUROLOGICAL SCIENCES, 2024, 45 (07) : 3147 - 3152
  • [8] Freezing of gait - Clinical overview
    Giladi, N
    GAIT DISORDERS, 2001, 87 : 191 - 197
  • [9] Freezing of Gait Questionnaire: validity and reliability of the Swedish version
    Nilsson, M. H.
    Hagell, P.
    ACTA NEUROLOGICA SCANDINAVICA, 2009, 120 (05): : 331 - 334
  • [10] Validation of the German Version of the New Freezing of Gait Questionnaire for People with Parkinson's Disease
    Seuthe, Jana
    Kuball, Kristina
    Hoffmann, Ann-Kristin
    Weisser, Burkhard
    Deuschl, Gunther
    Schlenstedt, Christian
    PARKINSONS DISEASE, 2021, 2021