Royal London space analysis: plaster versus digital model assessment

被引:0
|
作者
Grewal, Balpreet [1 ]
Lee, Robert T. [1 ]
Zou, Lifong [2 ]
Johal, Ama [1 ]
机构
[1] Queen Mary Univ London, Barts & London Sch Med & Dent, Inst Dent, Oral Growth & Dev, London, England
[2] Queen Mary Univ London, Barts & London Sch Med & Dent, Adult Oral Hlth, Inst Dent, London, England
关键词
ORTHODONTIC MEASUREMENTS; INTEGRATION; VALIDITY;
D O I
10.1093/ejo/cjw052
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: With the advent of digital study models, the importance of being able to evaluate space requirements becomes valuable to treatment planning and the justification for any required extraction pattern. This study was undertaken to compare the validity and reliability of the Royal London space analysis (RLSA) undertaken on plaster as compared with digital models. Materials and methods: A pilot study (n = 5) was undertaken on plaster and digital models to evaluate the feasibility of digital space planning. This also helped to determine the sample size calculation and as a result, 30 sets of study models with specified inclusion criteria were selected. All five components of the RLSA, namely: crowding; depth of occlusal curve; arch expansion/ contraction; incisor antero-posterior advancement and inclination (assessed from the pretreatment lateral cephalogram) were accounted for in relation to both model types. The plaster models served as the gold standard. Intra-operator measurement error (reliability) was evaluated along with a direct comparison of the measured digital values (validity) with the plaster models. Results: The measurement error or coefficient of repeatability was comparable for plaster and digital space analyses and ranged from 0.66 to 0.95 mm. No difference was found between the space analysis performed in either the upper or lower dental arch. Hence, the null hypothesis was accepted. The digital model measurements were consistently larger, albeit by a relatively small amount, than the plaster models (0.35 mm upper arch and 0.32 mm lower arch). Conclusion: No difference was detected in the RLSA when performed using either plaster or digital models. Thus, digital space analysis provides a valid and reproducible alternative method in the new era of digital records.
引用
收藏
页码:320 / 325
页数:6
相关论文
共 50 条
  • [1] Digital model as an alternative to plaster model in assessment of space analysis
    Kumar, A. Anand
    Phillip, Abraham
    Kumar, Sathesh
    Rawat, Anuradha
    Priya, Sakthi
    Kumaran, V.
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2015, 7 (06): : 465 - 469
  • [2] Comparison of space analysis evaluations with digital models and plaster dental casts
    Leifert, Michael F.
    Leifert, Melvyn M.
    Efstratiadis, Stella S.
    Cangialosi, Thomas J.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 16.e1 - 16.e4
  • [3] Orthodontic Plaster Casts Versus Digital Models
    Dunin-Wilczynska, Izabella
    Rudzki, Marcin
    Sidorowicz, Lukasz
    [J]. DENTAL AND MEDICAL PROBLEMS, 2011, 48 (04) : 519 - 524
  • [4] Is the Royal London Space Analysis reliable and does it influence orthodontic treatment decisions?
    Al-Abdallah, M.
    Sandler, J.
    O'Brien, K.
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2008, 30 (05) : 503 - 507
  • [5] Digital versus plaster study models: How accurate and reproducible are they?
    Abizadeh, Neilufar
    Moles, David R.
    O'Neill, Julian
    Noar, Joseph H.
    [J]. JOURNAL OF ORTHODONTICS, 2012, 39 (03) : 151 - 159
  • [6] The Royal London Space Planning: An integration of space analysis and treatment planning - Part II: The effect of other treatment procedures on space
    Kirschen, RH
    O'Higgins, EA
    Lee, RT
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2000, 118 (04) : 456 - 461
  • [7] Space planning sensitivity and specificity: Royal London Space Planning and Korkhaus Analyses
    Dause, Rania
    Cobourne, Martyn
    McDonald, Fraser
    [J]. AUSTRALIAN ORTHODONTIC JOURNAL, 2010, 26 (01) : 42 - 48
  • [8] Accuracy of space analysis with emodels and plaster models
    Mullen, S. Russell
    Martin, Chris A.
    Ngan, Peter
    Gladwin, Marcia
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 132 (03) : 346 - 352
  • [9] Acomparison of plaster, digital and reconstructed study model accuracy
    Luther, Friedy
    [J]. JOURNAL OF ORTHODONTICS, 2008, 35 (03) : 175 - 175
  • [10] The Royal London Space Planning: An integration of space analysis and treatment planning - Part I: Assessing the space required to meet treatment objectives
    Kirschen, RH
    O'Higgins, EA
    Lee, RT
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2000, 118 (04) : 448 - 455