Auto-calibration Method for Active 3D Endoscope System Using Silhouette of Pattern Projector

被引:0
|
作者
Furukawa, Ryo [1 ]
Naito, Masahito [1 ]
Miyazaki, Daisuke [1 ]
Baba, Masahi [1 ]
Hiura, Shinsaku [1 ]
Sanomura, Yoji [2 ]
Tanaka, Shinji [2 ]
Kawasaki, Hiroshi [3 ]
机构
[1] Hiroshima City Univ, Hiroshima, Japan
[2] Hiroshima Univ Hosp, Hiroshima, Japan
[3] Kyushu Univ, Fukuoka, Fukuoka, Japan
来源
关键词
D O I
10.1007/978-3-319-75786-5_19
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper, we develop an active stereo system for endoscope which requires auto-calibration, because a micro pattern projector is inserted through the instrument channel during an operation and cannot be fixed to the endoscope. For solution, a new auto-calibration technique with full 6-DOF estimation of an active stereo system without any extra devices nor extra pattern projections is proposed. In the technique, the pattern projector itself is simultaneously captured with a target scene by an endoscope camera and the silhouette of the pattern projector is used to conduct 2D-3D matching by using the knowledge of the shape of the projector. In addition, the markers which is included in the projection pattern are extracted and the distances from the closest epipolar lines are calculated as for the cost function. To enhance the robustness of the reconstruction, we also propose a simple high dynamic range (HDR) imaging system for an endoscope by alternating the input power of the pattern projector ON and OFF to blink the pattern so that exposure time will vary with beat frequency, realizing a virtual multi-exposure camera. By applying our auto calibration technique with HDR imaging system, we achieved a robust and accurate reconstruction of tissue in metric 3D under practical operation of the endoscopic system, such as reconstruction of the inside of a real stomach of a pig.
引用
收藏
页码:222 / 236
页数:15
相关论文
共 50 条
  • [1] 2-DOF auto-calibration for a 3D endoscope system based on active stereo
    Furukawa, Ryo
    Masutani, Ryunosuke
    Miyazaki, Daisuke
    Baba, Masashi
    Hiura, Shinsaku
    Visentini-Scarzanella, Marco
    Morinaga, Hiroki
    Kawasaki, Hiroshi
    Sagawa, Ryusuke
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 7937 - 7941
  • [2] Auto-calibration for multi-projector 3D display
    Tang, Shao
    Zhang, Lei
    Zhang, Yongbing
    [J]. OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY III, 2014, 9273
  • [3] Auto-calibration of a Laser 3D Color Digitization System
    Li, Xiaojie
    Ge, Bao-zhen
    Zhao, Dan
    Tian, Qing-guo
    Young, K. David
    [J]. DIGITAL HUMAN MODELING, PROCEEDINGS, 2009, 5620 : 691 - +
  • [4] 3D endoscope system using DOE projector
    Furukawa, Ryo
    Sanomura, Yoji
    Tanaka, Shinji
    Yoshida, Shigeto
    Sagawa, Ryusuke
    Visentini-Scarzanella, Marco
    Kawasaki, Hiroshi
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2091 - 2094
  • [5] Sensor Auto-Calibration on Dynamic Platforms in 3D
    Britt, Jordan
    Bevly, David M.
    [J]. PROCEEDINGS OF THE 26TH INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS 2013), 2013, : 2195 - 2203
  • [6] 3D Gaze Estimation for Head-Mounted Eye Tracking System With Auto-Calibration Method
    Liu, Meng
    Li, Youfu
    Liu, Hai
    [J]. IEEE ACCESS, 2020, 8 : 104207 - 104215
  • [7] Auto-calibration of a projector-camera stereo system for projection mapping
    Deglint, Jason
    Cameron, Andrew
    Scharfenberger, Christian
    Sekkati, Hicham
    Lamm, Mark
    Wong, Alexander
    Clausi, David A.
    [J]. JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2016, 24 (08) : 510 - 520
  • [8] Binocular Approach to 3D Pose Measurement with Auto-Calibration
    Habacher, Michael
    Harker, Matthew
    O'Leary, Paul
    [J]. 2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 881 - 886
  • [9] PATTERN PROJECTOR USING SUPERPOSITION OF DOUBLE MICROLENS ARRAYS FOR HYBRID 3D ENDOSCOPE
    Yang, Sung-Pyo
    Kim, Jae-Bum
    Jeong, Ki-Hun
    [J]. 2018 IEEE MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2018, : 422 - 425
  • [10] Research and realization of auto-calibration technique based on structured grating 3D measuring system
    Cheng, J. T.
    Zhao, C.
    He, W. T.
    [J]. E-ENGINEERING & DIGITAL ENTERPRISE TECHNOLOGY, 2008, 10-12 : 594 - 598