Experimental study of condenser material in the air conditioning system

被引:0
|
作者
Abdulwahab, Abdulkareem [1 ]
Mysen, Sami [1 ]
机构
[1] Almustaqbal Coll, Air Conditioning & Refrigerat Dept, Hillah, Iraq
关键词
Heat transfer; Fins; COP; Refrigerant; Condenser; Condensation;
D O I
10.1016/j.matpr.2021.09.303
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the air conditioning machine, condenser is considered to be the important component. The present study illustrates the condenser's performance with relevant experiments. The role of a condenser is to release the observed heat from the cooling system because the energy is removed out and the condensed air get drained out and proceeds with its path through the presence of the expansion valve. This present study literally focuses on the external fins and the condenser tubes through the heat transfer mode by the process of forced convection. The temperature changes were calculated for both air temperature system and refrigerator system and appropriate analysis was performed for evaluating the performance of the condenser. The dimensions of the fins, shape and tubing arrangements are also analyzed. The principle of a condenser is to expel the heat out of the refrigeration system by the condensation of vapor. Generally, there is no phase change occurring in the external fluids. In the condenser operated with forced convection mode, the circulated air over the specific surface is maintained with the help of a blower for effective heat transfer. The heat rejection from the condenser is theoretically calculated from the standard value of the compression cycles, without the considering the addition of heat supplied by the compressor inefficiency. The fluid flow of the refrigerant is assisted by the external gravity and hence the inlet tube is aligned at the top whereas the outlet tube is aligned at the bottom. The concept of pipe rising is excluded from the design and extensive care is taken for the adjustment of pipe levels during installation process. Horizontal or vertical air flow is commonly preferred. In the attempt of comparison with various tubes of different diameters, it is considered to focus on smaller tubes with varying diameters to match with the internal surface area of a larger segmental tube. Copyright (c) 2022 Elsevier Ltd. All rights reserved.Selection and peer-review under responsibility of the scientific committee of the International Conference on Recent Advances in Mechanical Engineering and Nanomaterials This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:860 / 864
页数:5
相关论文
共 50 条
  • [1] Experimental study on cooling performance of air conditioning system with dual independent evaporative condenser
    Liu, Huanwei
    Zhou, Qiushu
    Liu, Yuling
    Wang, Peifeng
    Wang, Defa
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 55 : 85 - 92
  • [2] Experimental and Analytical Study for Condenser Shading Effects on Air-conditioning System Performance
    Shehadi, Maher
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 9, 2020,
  • [3] A Computational Study on Utilizing Phase Change Material With a Condenser to Improve air Conditioning System Performance
    Sao, Arun Kumar
    Arora, Arun
    Sahu, Mukesh Kumar
    ENERGY STORAGE, 2024, 6 (06)
  • [5] Experimental investigation of air conditioning system using evaporative cooling condenser
    Wang, Tianwei
    Sheng, Chenguang
    Nnanna, A. G. Agwu
    ENERGY AND BUILDINGS, 2014, 81 : 435 - 443
  • [6] Experimental investigation of air conditioning system using evaporative cooling condenser
    Wang, T. (tianwei0512@gmail.com), 1600, Elsevier Ltd (81):
  • [7] Experimental verification of a condenser with liquid-vapor separation in an air conditioning system
    Chen, Xueqing
    Chen, Ying
    Deng, Lisheng
    Mo, Songping
    Zhang, Haiyan
    APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) : 48 - 54
  • [8] Characteristics of air conditioning system with an additional condenser
    Goto, Makoto
    Tanifuji, Koji
    Fujita, Masahiro
    Yamauchi, Tomohiro
    Ohuchida, Satoshi
    Nagata, Kenji
    Ueno, Isao
    Hasegawa, Tatsuya
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 23 - +
  • [9] EXPERIMENTAL INVESTIGATION OF PERFORMANCE OF A RESIDENTIAL AIR-CONDITIONING SYSTEM WITH AN EVAPORATIVELY COOLED CONDENSER
    GOSWAMI, DY
    MATHUR, GD
    KULKARNI, SM
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04): : 206 - 211
  • [10] Design and experimental study of a novel air conditioning system using evaporative condenser at a subway station in Beijing, China
    Pan, Song
    Pei, Fei
    Wei, Yixuan
    Wang, Hongwei
    Liu, Jiaping
    Zhang, Xingxing
    Li, Guoqing
    Gu, Yaxiu
    SUSTAINABLE CITIES AND SOCIETY, 2018, 43 : 550 - 562