Bulk and Surface Acoustic Wave Sensor Arrays for Multi-Analyte Detection: A Review

被引:84
|
作者
Laenge, Kerstin [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Microstruct Technol, Hermann von Helmholtz Pl 1, D-76344 Eggenstein Leopoldshafen, Germany
关键词
bulk acoustic wave; surface acoustic wave; quartz crystal microbalance; film bulk acoustic resonator; sensor array; chemical sensor; biosensor; electronic nose; electronic tongue; QUARTZ-CRYSTAL-MICROBALANCE; VOLATILE ORGANIC-COMPOUNDS; SAW E-NOSE; ELECTRONIC-NOSE; QUALITY-CONTROL; IMPRINTED POLYMERS; IMMUNOSENSOR ARRAY; URINARY PROTEINS; CABERNET FRANC; IONIC LIQUIDS;
D O I
10.3390/s19245382
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bulk acoustic wave (BAW) and surface acoustic wave (SAW) sensor devices have successfully been used in a wide variety of gas sensing, liquid sensing, and biosensing applications. Devices include BAW sensors using thickness shear modes and SAW sensors using Rayleigh waves or horizontally polarized shear waves (HPSWs). Analyte specificity and selectivity of the sensors are determined by the sensor coatings. If a group of analytes is to be detected or if only selective coatings (i.e., coatings responding to more than one analyte) are available, the use of multi-sensor arrays is advantageous, as the evaluation of the resulting signal patterns allows qualitative and quantitative characterization of the sample. Virtual sensor arrays utilize only one sensor but combine itwith enhanced signal evaluation methods or preceding sample separation, which results in similar results as obtained with multi-sensor arrays. Both array types have shown to be promising with regard to system integration and low costs. This review discusses principles and design considerations for acoustic multi-sensor and virtual sensor arrays and outlines the use of these arrays in multi-analyte detection applications, focusing mainly on developments of the past decade.
引用
收藏
页数:28
相关论文
共 50 条
  • [1] Image analysis for multi-analyte xerogel based sensor arrays
    Karri, SS
    Titus, AH
    Tehan, EC
    Tao, Z
    Tang, Y
    Bright, FV
    2005 IEEE SENSORS, VOLS 1 AND 2, 2005, : 373 - 376
  • [2] Mode-multiplex plasmonic sensor for multi-analyte detection
    Haider, Firoz
    Aoni, Rifat Ahmmed
    Ahmed, Rajib
    Mahdiraji, Ghafour Amouzad
    Azman, Mohd Fahmi
    Adikan, Faisal Rafiq Mohamad
    OPTICS LETTERS, 2020, 45 (14) : 3941 - 3944
  • [3] Rapid detection of common viruses using multi-analyte suspension arrays
    Yu, Daojun
    Wu, Shenghai
    Wang, Baohong
    Chen, Yunbo
    Li, Lanjuan
    JOURNAL OF VIROLOGICAL METHODS, 2011, 177 (01) : 64 - 70
  • [4] Hydrogel microarrays for multi-analyte detection
    Rounds, Rebecca M.
    Lee, Seungjoon
    Jeffords, Sarah
    Ibey, Bennett L.
    Pishko, Michael V.
    Cote, Gerard L.
    OPTICAL DIAGNOSTICS AND SENSING VII, 2007, 6445
  • [5] Optical chip for multi-analyte detection
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (01) : IV - VI
  • [6] Development of Novel LOVE wave biosensor for simultaneous detection of multi-analyte
    Oh, Haekwan
    Lee, Yeolho
    Lee, Soosuk
    Yang, Sang Sik
    Lee, Keekeun
    EUROSENSORS XXV, 2011, 25
  • [7] Focusing on Multi-Analyte Detection & Analysis
    Liszewski, Kathy
    GENETIC ENGINEERING & BIOTECHNOLOGY NEWS, 2012, 32 (21): : 24 - 25
  • [8] MULTI-ANALYTE IMMUNOASSAY FOR PESTICIDES: A REVIEW
    Jiang, He
    Fan, Ming-Tao
    ANALYTICAL LETTERS, 2012, 45 (11) : 1347 - 1364
  • [9] Multi-analyte surface plasmon resonance biosensing
    Homola, J
    Vaisocherová, H
    Dostálek, J
    Piliarik, M
    METHODS, 2005, 37 (01) : 26 - 36
  • [10] Surface plasmon resonance based multi-channel and multi-analyte fiber optic sensor
    Verma, Roli
    Srivastava, Sachin K.
    Gupta, Banshi D.
    THIRD ASIA PACIFIC OPTICAL SENSORS CONFERENCE, 2012, 8351